Order Entry
United States
Orders LinkContactUsLinkComponent
164 results for "Solid Phase Extraction"

"Solid Phase Extraction"

164 Results
Sort by
Empore™ Solid Phase Extraction Stage Tips, CDS Analytical

Empore™ Solid Phase Extraction Stage Tips, CDS Analytical

Supplier: CDS ANALYTICAL

The original Empore SPE membrane is now available in pre-packed StageTips and are the only solution to save time and improve reproducibility of peptide / protein desalting and fractionation.

Expand 8 Items
Loading...

Acetonitrile

Supplier: Aladdin Scientific

Acetonitrile, an aliphatic nitrile, is a highly volatile, aprotic polar organic solvent that finds wide use in analytical determinations. It is UV-transparent - a property that facilitates its utilization in spectrophotometric and fluorimetric analyses. Its low viscosity, high elution strength and miscibility in water makes it viable in many chromatography systems. Its other applications include its use as a mobile phase additive and as an extraction solvent in liquid-liquid extraction (LLC), solid-phase extraction (SPE) and microextraction for chromatographic applications, etc.

Expand 2 Items
Loading...
Empore™ Solid Phase Extraction RAD Disks, CDS Analytical

Empore™ Solid Phase Extraction RAD Disks, CDS Analytical

Supplier: CDS ANALYTICAL

Empore RAD disks provide an efficient alternative to conventional radiochemical sample preparation methods that use wet chemistry or packed columns.

Expand 3 Items
Loading...
VACUUBRAND® Dry Chemistry Diaphragm Pumps, BrandTech

VACUUBRAND® Dry Chemistry Diaphragm Pumps, BrandTech

Supplier: Brandtech

Powerful and popular oil-free diaphragm vacuum pumps are suitable for a wide variety of laboratory applications such as rotary evaporation, centrifugal concentration, gel drying, vacuum filtration, solid phase extraction, and degassing procedures

Expand 12 Items
Loading...

SPME Fibers and Arrows

Supplier: Thermo Scientific

Automate solvent-free solid phase micro extraction (SPME) sample preparation by performing sample extraction and enrichment in a single step using Thermo Scientific™ SPME Arrow and SPME Fiber products. These products are used with the Thermo Scientific™ TriPlus RSH™ autosampler prior to gas chromatography (GC) or gas chromatography mass spectrometry (GC/MS) analysis.

Expand 16 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Metrafenone

Supplier: MilliporeSigma

Metrafenone CRM may also be used in the residue analysis of: 209 pesticides and persistent organic pollutants (POPs) extracted by QuEChERS-based procedure from fresh bovine and chicken liver samples using gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). 379 pesticides in human serum samples extracted by QuEChERS method using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Metrafenone in nine fresh vegetable samples using matrix solid-phase dispersion (MSPD) and HPLC-UV. Metrafenone in bitter gourd and soil samples using gas chromatography combined with an electron capture detector (GC-ECD).

Expand 1 Items
Loading...

3-Bromobenzoic acid

Supplier: Aladdin Scientific

Usually used as test solute in the determination of acidity constants by capillary zone electrophoresis, internal standard to study the retention mechanisms of an unmodified and a hydroxylated polystyrene-divinylbenzene polymer by solid-phase extraction. And also used in synthesis of N-(1,1-dimethyl-2-hydroxyethyl)-3-bromobenzamide.

Expand 1 Items
Loading...

Bismuth(III) citrate

Supplier: Aladdin Scientific

DescriptionBismuth(III) citrate has been used as a sorbent in spin columns to develop a novel stationary phase for the selective and efficient isolation of phenolic compounds from natural sources via solid phase extraction (SPE) method. It can be used to synthesize bismuth subcarbonate ((BiO)2 CO3) nanotubes that are reported to show antibacterial property againstHelicobacter pylori.

Expand 1 Items
Loading...
VACUUBRAND® Dry Chemistry Diaphragm Pump, Trade-Up Promotion

VACUUBRAND® Dry Chemistry Diaphragm Pump, Trade-Up Promotion

Supplier: Brandtech

Powerful and popular oil-free diaphragm vacuum pumps are suitable for a wide variety of laboratory applications such as rotary evaporation, centrifugal concentration, gel drying, vacuum filtration, solid phase extraction, and degassing procedures.

Expand 3 Items
Loading...
Rtx®-Mineral Oil Columns (Fused Silica), Restek

Rtx®-Mineral Oil Columns (Fused Silica), Restek

Supplier: Restek

The Rtx®-Mineral Oil stationary phase and column dimensions are optimized for the fast screening of mineral oils in extracts from solids and water samples according to DIN EN ISO 9377-2:2000.

Expand 3 Items
Loading...

Accessories for VACUUBRAND® Oil-Free Vacuum Pumps for Filtration and Solid Phase Extraction, Brand

Supplier: Brandtech

For VACUUBRAND ME1C vacuum pump. Bleeder valve allows adjustment of vacuum level. Manometer is graduated from atmosphere to -1 bar, in graduations of 0.05 bar.

Expand 2 Items
Loading...

Cyclohexane

Supplier: Aladdin Scientific

It is saturated hydrocarbon which has a six membered ring-structure, and it is derived from the catalytic hydrogenation of benzene. It is usually used as a solvent for cellulosics, and exists as an intermediate during the production of nylon. It was used with ethyl acetate as an organic solvent, in dispersice solid-phase extraction, for the determination of pesticide residues in fruits and vegetables.

Expand 2 Items
Loading...
VACUUBRAND® ME 1C Oil-Free Chemistry Diaphragm Pump, Trade-Up Promotion

VACUUBRAND® ME 1C Oil-Free Chemistry Diaphragm Pump, Trade-Up Promotion

Supplier: Brandtech

The ME 1C diaphragm vacuum pumps offer a compact, high performance and easy-to-use solution which is perfect for both single and multiple filtrations, solid phase extraction (SPE) and other fluid movement tasks.

Expand 1 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Monolinuron

Supplier: MilliporeSigma

Monolinuron CRM may also be used as given below: Determination of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Extraction of 13 pesticides from four groundwater and three river water samples using silica-based MSU-1 mesoporous solid as a sorbent for their solid-phase extraction (SPE) followed by ultra-performance liquid chromatography-triple quadrupole-mass spectrometric (UHPLC- QqQ-MS/MS) determination. Development and validation of a UHPLC-diode array detection (DAD) method for simultaneous determination of urea and tebuthiuron herbicides in four fresh vegetable samples. Multi-residue analysis of 50 herbicides in 51 grain samples of soybean corn and wheat by ultra-performance liquid chromatography-electrospray ionization-mass spectrometry (UPLC-ESI-MS). Extraction of 109 pesticide residues from different chemical classes from 345 tomato samples by modified QuEChERS method and their determination using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Simultaneous analysis of 238 pesticides and 78 veterinary drugs in 80 bovine milk samples using ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS).

Expand 1 Items
Loading...
Accessories for Extrelut® NT, MilliporeSigma

Accessories for Extrelut® NT, MilliporeSigma

Supplier: MilliporeSigma

Extrelut® NT simplifies liquid-liquid extraction in its most effective form by using a chemically inert, wide-pore and highly pure diatomaceous earth based solid phase.

Expand 5 Items
Loading...

2-Amino-3-chloro-1,4-naphthoquinone ≥98% (by HPLC)

Supplier: Aladdin Scientific

Product Application:Quinoclamine may be used as an analytical reference standard for the determination of the analyte in:Honeybees by dispersive solid-phase extraction (dSPE), followed by liquid and gas chromatography coupled with tandem mass spectrometry (LC-MS/MS and GC-MS/MS).Chlorophyll-containing matrix by dSPE and GC-MS/MS.

Expand 2 Items
Loading...
Recommendations

Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".

Otherwise, you will receive generic recommendations.