Order Entry
United States
ContactUsLinkComponent
706 results for "GC STANDARDS"

 

Sort By

Phytocannabinoid Mixture 10 (CRM), Cayman Chemical

Supplier: Cayman Chemical Company

A Certified Reference Material cintaining a mixture of phytocannabinoids in an acetonitrile solution intended for HPLC-UV or LC- or GC-MS applications

Expand 1 Items
 

Phytocannabinoid Mixture 11 (CRM) (1 ml, 100 µg/ml), Cayman Chemical

Supplier: Cayman Chemical Company

A mixture of phytocannabinoids in an acetonitrile solution intended for HPLC-UV or LC- or GC-MS

Expand 1 Items
 

Phytocannabinoid Mixture 11 (CRM) (0.5 ml, 1 mg/ml), Cayman Chemical

Supplier: Cayman Chemical Company

A mixture of phytocannabinoids in an acetonitrile solution intended for HPLC-UV or LC- or GC-MS

Expand 1 Items
 
Internal Volatile Standard

Internal Volatile Standard

Supplier: SPEX CERTIPREP LLC

Volatiles, US EPA method 524.3 is a GC/MS method for the analysis of purgeable VOCs in finished drinking water. Analytes added to Methanol 524.3 revision 4 are supplied in a 24-component mix.

Expand 1 Items
 
Vydac 214ATP C4, HPLC Columns

Vydac 214ATP C4, HPLC Columns

Supplier: Avantor

Vydac TP was the first range of wide pore media phases developed in the Vydac range and became the industry standard for peptide and protein separations.

    
Expand 4 Items
 
Alcohols Mix

Alcohols Mix

Supplier: SPEX CERTIPREP LLC

US EPA method 8015 is a general analytical method for the monitoring of certain non-halogenated VOCs and SVOCs by GC/FID.

Expand 1 Items
 
Base Neutral and Acid Combination Calibration Standard

Base Neutral and Acid Combination Calibration Standard

Supplier: SPEX CERTIPREP LLC

Semivolatiles, US EPA method 625 is an analytical method for the monitoring of acid and base neutral extractable fractions in municipal and industrial wastewater by GC/MS. US EPA method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS. CLP series methods: The US EPA retains analytical services through the Contract Laboratory Program (CLP). The CLP follows detailed SOPs derived from EPA methods and SW-846. The CLP volatile organic analysis method is an analytical method for the analysis of aqueous or solid samples for VOCs by GC/MS.

Expand 1 Items
 

Aroclor 1254 for US EPA Methods 505, 508, 608, 625, 8082, CLP Series Methods, and ASTM Method D6160, SPEX CertiPrep

Supplier: SPEX CERTIPREP LLC

Semivolatiles

US EPA Method 625 is an analytical method for the monitoring of acid and base neutral extractable fractions in municipal and industrial wastewater by GC/MS.

US EPA Method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS.

Expand 1 Items
 
Nitrosamines Mix

Nitrosamines Mix

Supplier: SPEX CERTIPREP LLC

US EPA method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS.

Expand 1 Items
 
HICAL Acids Mix

HICAL Acids Mix

Supplier: SPEX CERTIPREP LLC

Semivolatiles, US EPA Method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS.

Expand 1 Items
 

PCB-Free Transformer Oil, Restek

Supplier: Restek

ASTM Method D4059-00 is used for determining PCB concentrations in various types of transformer oil using GC-ECD detection

Expand 2 Items
 
Vydac 219TP Diphenyl, HPLC Columns

Vydac 219TP Diphenyl, HPLC Columns

Supplier: Avantor

Vydac TP was the first range of wide pore media phases developed in the Vydac range and became the industry standard for peptide and protein separations.

    
Expand 10 Items
 
Trihalomethanes Voaltiles Mix

Trihalomethanes Voaltiles Mix

Supplier: SPEX CERTIPREP LLC

Volatiles US EPA method 502.2 is a general analytical method for the monitoring of halogenated, purgeable VOCs in drinking water and raw water sources by GC megabore capillary column techniques and hall and Photoionization Detectors (PID).

Expand 1 Items
 

Semivolatiles MegaMix Standard, EPA Method 625, (54 Components), Restek

Supplier: Restek

This contais 54 components, incorporates all phenols, for fast preparation and calibration, incorporates 'additional' extractable method 625 compounds. GC-MS method applicable to analysis of organic compounds in water and soil.

Expand 1 Items
 
Surrogate Standard

Surrogate Standard

Supplier: SPEX CERTIPREP LLC

Volatiles, US EPA method 524.3 is a GC/MS method for the analysis of purgeable VOCs in finished drinking water. Analytes added to Methanol 524.3 revision 4 are supplied in a 24-component mix.

Expand 1 Items
 
PAH MIX 2000PPM 1ML

PAH MIX 2000PPM 1ML

Supplier: SPEX CERTIPREP LLC

Semivolatiles, US EPA Method 625 is an analytical method for the monitoring of acid and base neutral extractable fractions in municipal and industrial wastewater by GC/MS. US EPA Method 8100 is an analytical method for the monitoring of PNA hydrocarbons in aqueous and solid samples by GC/FID.

Expand 1 Items
 
Volatile Organics Combination Analyte Mix

Volatile Organics Combination Analyte Mix

Supplier: SPEX CERTIPREP LLC

US EPA method 624 is a general analytical method for the monitoring of VOCs in municipal and industrial wastewater by GC/MS.

Expand 1 Items
 
J&W HP-1 Columns, Agilent Technologies

J&W HP-1 Columns, Agilent Technologies

Supplier: AGILENT TECHNOLOGIES, INC (CSD)

A nonpolar 100% polydimethylsiloxane, general-purpose, industry-standard column for the analysis of hydrocarbons, pesticides, PCBs, and sulfur compounds.

Expand 68 Items
 
Purgeable Gases Mix B (High Level)

Purgeable Gases Mix B (High Level)

Supplier: SPEX CERTIPREP LLC

US EPA method 502.1 is a general analytical method for the monitoring of halogenated, portable VOCs in drinking water and raw water sources by GC with a hall detector. US EPA method 502.2 is a general analytical method for the monitoring of halogenated, purgeable VOCs in drinking water and raw water sources by GC megabore capillary column techniques and hall and photoionization detectors (PID).

Expand 1 Items
 
Vydac 218TP C18, HPLC Columns

Vydac 218TP C18, HPLC Columns

Supplier: Avantor

Vydac TP was the first range of wide pore media phases developed in the Vydac range and became the industry standard for peptide and protein separations.

    
Expand 43 Items
 
Vydac 201TP C18, HPLC Columns

Vydac 201TP C18, HPLC Columns

Supplier: Avantor

Vydac TP was the first range of wide pore media phases developed in the Vydac range and became the industry standard for peptide and protein separations.

    
Expand 12 Items
 
Vydac 214TP C4, HPLC Columns

Vydac 214TP C4, HPLC Columns

Supplier: Avantor

Vydac TP was the first range of wide pore media phases developed in the Vydac range and became the industry standard for peptide and protein separations.

    
Expand 39 Items
 
Vydac 202TP C18-HL, HPLC Columns

Vydac 202TP C18-HL, HPLC Columns

Supplier: Avantor

Vydac TP was the first range of wide pore media phases developed in the Vydac range and became the industry standard for peptide and protein separations.

    
Expand 1 Items
 
FlashPure ID Silica and C18 Flash Cartridges, Büchi

FlashPure ID Silica and C18 Flash Cartridges, Büchi

Supplier: Buchi

Standard Silica Flash Cartridges are used for optimum chromatographic performance.

Expand 7 Items
 

Aroclor 1260 for US EPA Methods 505, 508, 608, 625, 8082, CLP Series Methods, and ASTM Method D6160, SPEX CertiPrep

Supplier: SPEX CERTIPREP LLC

Semivolatiles

US EPA Method 625 is an analytical method for the monitoring of acid and base neutral extractable fractions in municipal and industrial wastewater by GC/MS.

US EPA Method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS.

Expand 1 Items
 
GsBP®-FFAP Polar, PEG GC Columns, GS-Tek

GsBP®-FFAP Polar, PEG GC Columns, GS-Tek

Supplier: General Separation Technologies, Inc.

Typical Application: Acrylates, Alcoholic Beverage Standard: Acids & Esters, Aspirin and Ibuprofen in Methanol, Cresylic Acids, Ethoxyethanol, Fatty Acids (Free), Malt Whiskey, Organic Acids.

Expand 23 Items
 

Aroclor 1242 for US EPA Methods 505, 508, 608, 625, 8082, CLP Series Methods, and ASTM Method D6160, SPEX CertiPrep

Supplier: SPEX CERTIPREP LLC

Semivolatiles

US EPA Method 625 is an analytical method for the monitoring of acid and base neutral extractable fractions in municipal and industrial wastewater by GC/MS.

US EPA Method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS.

Expand 1 Items
 

Aroclor 1248 for US EPA Methods 505, 508, 608, 625, 8082, CLP Series Methods, and ASTM Method D6160, SPEX CertiPrep

Supplier: SPEX CERTIPREP LLC

Semivolatiles

US EPA Method 625 is an analytical method for the monitoring of acid and base neutral extractable fractions in municipal and industrial wastewater by GC/MS.

US EPA Method 8270 is a general analytical method for the monitoring of semivolatiles in environmental and waste samples by GC/MS.

Expand 1 Items
 
Vydac 208TP C8, HPLC Columns

Vydac 208TP C8, HPLC Columns

Supplier: Avantor

Vydac TP was the first range of wide pore media phases developed in the Vydac range and became the industry standard for peptide and protein separations.

    
Expand 20 Items
 
Method 524.2 Revision 4 Mix

Method 524.2 Revision 4 Mix

Supplier: SPEX CERTIPREP LLC

US EPA method 524.3 is a GC/MS method for the analysis of purgeable VOCs in finished drinking water. Analytes added to methanol 524.3 revision 4 are supplied in a 24-component mix.

Expand 1 Items
 
Sort By
Recommended for You