FilterMax™ F3 and F5 Multimode Microplate Readers, Molecular Devices
FilterMax™ F3 and F5 Multimode Microplate Readers, Molecular Devices
Supplier:  Molecular Devices
Certificates
undefined
FilterMax™ F3 and F5 Multimode Microplate Readers, Molecular Devices
Supplier:  Molecular Devices

Specifications

  • Catalog No:
  • 97059-524
  • 97059-526
  • Wavelength Range:
  • 340–650 nm in Fluorescence Intensity-Top Read Mode, 400–650 nm in Luminescence (Glow) Mode, 340–650 nm in Absorbance Mode
  • 230–750 nm in Fluorescence Intensity-Top Read Mode, 300–650 nm in Fluorescence Intensity-Bottom Read Mode, 340–750 nm in Time-Resolved Fluorescence Mode, 340–750 nm in Fluorescence Polarization Mode, 400–750 nm Luminescence (Glow) Mode, 230–650 nm in Absorbance Mode
  • Accuracy:
  • <+1% +10 mOD at 2 OD in Absorbance Mode
  • <+1% + 10 mOD at 2 OD in Absorbance Mode
  • Detection Limit (384-Well):
  • 3 fmol/100 µl fluorescein in Fluorescence Intensity-Top Read Mode
  • 0.4 fmol/100 µl fluorescein in Fluorescence Intensity-Top Read Mode, 0.5 fmol/100 µl fluorescein in Fluorescence Intensity-Bottom Read Mode, 15 amol/100 µl Europium in Time-Resolved Fluorescence Mode, 4 mP at 10nM Fluorescein in Fluorescence Polarization Mode
  • Detection Limit (96-Well):
  • 3 fmol/200 µl fluorescein in Fluorescence Intensity-Top Read Mode, 2 fmol ATP in Luminescence (Glow) Mode
  • 3 fmol/100 µl fluorescein in Fluorescence Intensity-Top Read Mode, 25 fmol/200 µl fluorescein in Fluorescence Intensity-Bottom Read Mode, 30 amol/200 µl Europium in Time-Resolved Fluorescence, 3 mP at 10nM Fluorescein in Fluorescence Polarization Mode, 2 fmol ATP in Luminescence (Glow) Mode
  • Dimensions:
  • 39W x 24H x 58L cm
  • 39W x 24H x 58L cm
  • Indication Range:
  • 0–3.5 OD in Absorbance Mode
  • 0-3.5 OD in Absorbance Mode
  • Linear Dynamic Range:
  • 6 decades in Fluorescence Intensity-Top Read Mode, 6 decades in Luminescence (Glow) Mode
  • 6 Decades in Fluorescence Intensity-Top Read Mode, 5 Decades in Time-Resolved Fluorescence
  • Measurement Mode:
  • Endpoint, Kinetic, Linear Scan, Area Scan
  • Endpoint, Kinetic, Linear Scan, Area Scan
  • Plate Format:
  • 96–384 well
  • 6–1536 well
  • Read Time:
  • 18 sec. on 96-well and 37 sec. on 384-well in Absorbance Mode
  • 180sec/96well; 690sec/384well (1sec integration time) in Time-Resolved Fluorescence Mode, 18sec/96well; 37sec/384well in Absorbance Mode
  • Read Time (Fly Mode):
  • 18 sec. on 96-well and 37 sec. on 384-well in Fluorescence Intensity-Top Read Mode, 18 sec. on 96-well and 37 sec. on 384-well in Luminescence (Glow) Mode
  • 18sec/96well; 37sec/384well in Fluorescence Intensity-Top Read Mode, 38sec/96well; 79sec/384well in Flourescence Polarization Mode, 18sec/96well; 37sec/384well in Luminescence (Glow) Mode
  • Reproducibility:
  • <+0.5% and +0.005 OD at 2 OD in Absorbance Mode
  • <+0.5% and +0.005 OD at 2 OD in Absorbance Mode
  • Shaking:
  • Linear and Orbital
  • Linear and Orbital

Specifications