Order Entry
United States
Orders LinkContactUsLinkComponent
 

VWR® Air Jacketed CO₂ Incubator, Basic

Basic CO2 Incubator Air Jacket, 5.3 CF
  10810-888
CSA Certified
VWR® Air Jacketed CO₂ Incubator, Basic
  10810-888
CSA Certified
VWR® Air Jacketed CO₂ Incubator, Basic
VWR® Air Jacketed CO₂ Incubator, Basic

Basic CO2 Incubator Air Jacket, 5.3 CF

 
$6,131.38
 
   
Each
 

The VWR® Air Jacket CO2 Incubator Basic delivers value and performance for everyday cell culture applications by providing a reliable growth environment with added convenience of on-demand high heat decontamination.

  • 5.3 cu. ft. stainless steel internal chamber volume with three standard shelves
  • Exceptional value with high heat decontamination
  • On-demand 90 °C moist heat decontamination cycle for simplified cleaning
  • Fan-assisted airflow and in-chamber sensors maintain a uniform and stable growth environment
  • Dual temperature probes for over-temperature protection and TC CO2 sensor for long lasting, reliable performance
  • Integrated pan design for fast recovery and high relative humidity
  • Easy-to-install and dismantle shelf system with rounded corners for easy cleaning
  • Three-year part and labor warranty

On-demand 90 °C moist heat cycle decontaminates entire chamber interior without the need to remove sensors, fittings, and shelves

Feel safe with a VWR® CO2 incubator that provides you with selection, performance and quality needed in today’s cell culture laboratories. VWR® family of CO2 incubators include water jacketed and air jacketed configurations to meet specific culturing preferences and a wide range of solutions to meet capacity and budget needs. A choice of platform designs and capacities are available to meet your specific culturing preferences. Options include capacities ranging from 1.4 to 6.5 cu. ft., water jacketed models for outstanding temperature stability, and low maintenance air jacketed models with high temperature decontamination cycles.

Choice of small-capacity models for low-volume culturing needs. Stackable models are available to maximize lab space. Choose between thermal conductivity or infrared CO2 sensors to meet preference and application needs. Optional available enhanced contamination control technologies include HEPA filtration and high temperature decontamination. These advanced technologies and contamination control provide a safe growth environment for your cultures. Feel confident that your cultures are in a stable and protected growth environment. Exceptional value for your lab. Fan assisted airflow designed for rapid recovery and uniform conditions. In-chamber probes and sensors designed for precise control. Dual temperatures for over-temperature protection. Polished, high grade stainless steel chambers.

Independent laboratory tests have validated that 90 °C moist heat decontamination is highly effective against wide range of contaminants, including mycoplasma.

 : VWR CATALYST™ offers customer on-site Calibration, Preventative Maintenance and validation services including IQ, OQ, and PQ protocol development and execution services (US only).Please Call 888-793-2300 or visit www.vwr.com/equip_services for more details.

White Glove Installation and Verification Service–the white glove installation includes unpacking, inspection, removal/disposal of packing materials, transporting order via elevator and merchandise set up in the room of your choice, installation of casters or leveling feet, power and electrical connections inspected, supply voltage verified, functional and performance verification documented. Our engineers will move the unit from the customer's receiving dock to the lab within the same building. This service does NOT include transportation from vendor warehouse to customer's receiving dock.

 
  • Volume:
    5.3 CF
  • Description:
    Basic CO2 Incubator Air Jacket
  • Cat. No.:
    10810-888
  • Electrical:
    120V
Services

 

  •  
    Includes
    Service coverage
    Description
    Out-of-service coverage
    Details
     
     
  • 76006-268
    IQ/OQ will be performed as described in the (IQ/OQ) section. The PQ consists of loaded chamber temperature mapping at a single temperature for an additional 24 hours.
    Philadelphia, PA; New York, NY; Baltimore, MD; Minneapolis, MN; Houston, TX; Austin, TX; Los Angeles, CA; San Francisco, CA
    CO2 Incubator IOPQ
    Other service/area/brand, please visit www.vwr.com/equip_services or call 888.793.2300 to get a quote
    Each device has been installed, powered up and equilibrated for 24 hours before on-site service.
       
    Each - $3,994.89

  • 76006-264
    Calibration at a single temperature and CO2 point using NIST traceable standards. Upon completion, a calibration form will be provided with “as found” and “as left” measurements.
    Philadelphia, PA; New York, NY; Baltimore, MD; Minneapolis, MN; Houston, TX; Austin, TX; Los Angeles, CA; San Francisco, CA
    CO2 Incubator Calibration
    Other service/area/brand, please visit www.vwr.com/equip_services or call 888.793.2300 to get a quote
    Each device has been installed, powered up and equilibrated for 24 hours before on-site service.
       
    Each - $286.59

  • 76006-266
    PM & Calibration service includes cleaning of seals, fans, and gaskets. The interior and exterior of the chamber is inspected. After PM, technicians will calibrate the chamber as described in Calibration section.
    Philadelphia, PA; New York, NY; Baltimore, MD; Minneapolis, MN; Houston, TX; Austin, TX; Los Angeles, CA; San Francisco, CA
    CO2 Incubator PM and Calibration
    Other service/area/brand, please visit www.vwr.com/equip_services or call 888.793.2300 to get a quote
    Each device has been installed, powered up and equilibrated for 24 hours before on-site service.
       
    Each - $373.43

  • 76006-270
    Validation (IQ/OQ) includes a standardized protocol procedure, calibration, IQ (verify design spec, system SOP, environmental conditions etc.), and OQ (Perform empty chamber temperature mapping at a single temperature, open door and power loss testing).
    Philadelphia, PA; New York, NY; Baltimore, MD; Minneapolis, MN; Houston, TX; Austin, TX; Los Angeles, CA; San Francisco, CA
    CO2 Incubator IOQ
    Other service/area/brand, please visit www.vwr.com/equip_services or call 888.793.2300 to get a quote
    Each device has been installed, powered up and equilibrated for 24 hours before on-site service.
       
    Each - $3,265.37

Complementary Products

 

  •  
    Accuracy
    Description
    Probe
    Range
    Resolution
     
     
  • 10048-644
    ±0.25 °C
    VWR® Traceable® Excursion-Trac® Thermometer
    1 stainless steel probe
    –50.0…+70.0 °C (–58…+158 °F)
    0.01°C
       
    Each - $220.45

Accessories

 

  •  
    Description
     
     
  • 82013-766
    Support Frame with Casters, 63.5W x 61D x 20.3H cm (25 x 24 x 8"), for Model 5.3A Incubators
       
    Each - $1,120.87

 

  •  
    Description
     
     
  • 98000-390
    Single Stainless Steel Shelf with Installation Channel, for Model 5.3A Incubators
       
    Each - $412.94