You searched for: Sterilization Indicators
Changing appearances in color or pattern, the sterilization indicators visually show if cleaning conditions are passing or procedures have been completed. Eliminating any confusion or possibility instruments will not be sterile, indicators are used routinely in clinical and research environments where contamination elimination is crucial. With the temperature resistance required to endure the purification, the sterilization indicators are available in different forms such as tapes, ampoules, and sticks.
Comply™ Bowie-Dick Plus Test Packs, 3M™
Supplier: Healthcare Products
Comply™ Bowie-Dick test packs are used to monitor the performance of vacuum-assisted 132 to 134 °C (270 to 273 °F) steam sterilizers.
Expand 2 Items
Bionova® 24 h Biological Indicator for Hydrogen Peroxide
Supplier: TERRAGENE
Self-contained biological indicator for plasma or vaporized hydrogen peroxide sterilization processes. Geobacillus stearothermophilus (ATCC7953) 10⁵ spores per vial. Readout: 24 hours.
Expand 1 Items
BI-OK® EO Gas Biological Indicator Vials, Propper Manufacturing
Supplier: Propper
BI-OK® biological indicators are a reliable method to test ethylene oxide sterilization cycles.
Expand 1 Items
Steam Chex™ Lead-Free Blue Autoclave Indicator Tapes, Propper Manufacturing Company
Supplier: Propper
Steam Chex™ lead free autoclave steam indicator tape is pressure-sensitive sterilization tape that is used to distinguish between processed and unprocessed items.
Expand 2 Items
Bionova® 24 h Biological Indicator for Steam 10⁶
Supplier: TERRAGENE
Self-contained biological indicator for steam sterilization processes. Geobacillus stearothermophilus (ATCC 7953) 10⁶ spores per vial. Readout: 24 hours.
Expand 1 Items
Attest™ Biological Indicators for EO, 3M™
Supplier: Healthcare Products
3M™ Attest™ self-contained BI is designed for monitoring ethylene oxide (EO) sterilization processes.
Expand 1 Items
Comply™ Chemical Integrators, 3M™
Supplier: Healthcare Products
Comply™ Chemical Integrators provides an immediate, accurate, and easy-to-read method of monitoring sterilization process conditions inside each pack.
Expand 3 Items
Chemdye® Bowie-Dick Test Card Kit for Steam (FDA)
Supplier: TERRAGENE
Bowie - Dick test card kit for Steam sterilization processes, includes Bowie - Dick-test card chemical indicators and holder. 1 holder+120 test cards.
Expand 1 Items
Bionova® 24 h Biological Indicator for Hydrogen Peroxide
Supplier: TERRAGENE
Self-contained biological indicator for plasma or vaporized hydrogen peroxide sterilization processes. Geobacillus stearothermophilus (ATCC7953) 10⁶ spores per vial. Readout: 24 hours.
Expand 1 Items
VERIFY™ Bowie-Dick Test Pack, STERIS®
Supplier: Steris
Bowie-Dick Tests verify that the prevacuum sterilizer effectively removes air and provides efficient steam penetration.
Expand 1 Items
Bionova® 3 h Biological Indicator for Steam (FDA)
Supplier: TERRAGENE
Rapid self-contained biological indicator for steam sterilization processes. Geobacillus stearothermophilus (ATCC® 7953) 10⁶ spores per vial. Readout: 3 hours.
Expand 1 Items
Paper for Bionova® MiniPro and MiniBio Auto-Reader
Supplier: TERRAGENE
Paper for Bionova® MiniPro and MiniBio Auto-Reader
Expand 1 Items
Bionova® Spore Strips for Dry Heat, Steam and Ethylene Oxide
Supplier: TERRAGENE
Spore strips biological indicator for steam, ethylene oxide and dry heat sterilization processes. Geobacillus stearothermophilus (ATCC® 7953) 10⁶ and Bacillus atrophaeus (ATCC® 9372) 10⁶ spores per strip. Readout time 24/48 hours. It is suggested the use of Bionova® MC1020-2 culture medium.
Expand 1 Items
STERIL-PEEL™ Self-Seal Sterilization Rolls, GS Medical Packaging
Supplier: GS Medical Packaging
All STERIL-PEEL™ products are manufactured from medical grade bleached kraft paper
Expand 6 Items
Chemdye® Self-Adhesive Label Indicator for Hydrogen Peroxide
Supplier: TERRAGENE
Automatic record system. chemical indicator, double self-adhesive labels printed with indicator ink (29×22.5 mm), for plasma or vaporized hydrogen peroxide sterilization processes. Rolls of 750 labels. Turns from purple to green.
Expand 1 Items
Integron® Chemical Integrator for Steam (FDA)
Supplier: TERRAGENE
Unique point chemical integrator for steam sterilization processes between 121 and 134 °C. ISO 11140-1 Type 5.
Expand 1 Items
Bionova® Self-Contained Spore Ampoules for Steam (10⁶ Spores/0,25 ml)
Supplier: TERRAGENE
Self-contained spore ampoules for monitoring industrial steam sterilization of liquids. Geobacillus stearothermophilus (ATCC 7953) 10⁶ spores per ampoule (7×27 mm). 0.25 ml of culture medium. 200(+)+20(-)/BX.
Expand 1 Items
Bionova® Spore Ampoule for Dry Heat Sterilization Processes
Supplier: TERRAGENE
Spore ampoule for dry heat sterilization processes. Bacillus atrophaeus (ATCC® 9372). 10⁶ spores per ampule. Each box of 50 ampules. Readout: 72 hours. The contents of the ampoule should be incubated in the Bionova® MC1020-2 culture medium tube or a culture medium suitable for the growth of Bacillus atrophaeus ATCC® 9372.
Expand 1 Items
Bionova® Spore Strips for Steam and LTSF (10⁶ Spores)
Supplier: TERRAGENE
Spore strips biological indicator for steam and formaldehyde sterilization processes. Geobacillus stearothermophilus (ATCC 7953) 10⁶ spores per strip. It is suggested the use of Bionova® MC1020-2 culture medium. Read out after 24 hours for Steam, or 48 hours for formaldehyde.
Expand 1 Items
Bionova® Spore Strips for Gamma Radiation (10⁶ Spores)
Supplier: TERRAGENE
Spore strips biological indicator for Gamma Radiation sterilization processes. Bacillus pumilus (ATCC 27142) 10⁶ spores per strip. It is suggested the use of Bionova® MC1020-2 culture medium. Readout in 48 hours.
Expand 1 Items
Chemdye® Bowie-Dick Test Pack (ISO 11140-5) (FDA)
Supplier: TERRAGENE
Bowie - Dick test pack chemical indicator for Steam sterilization. Size: (125×125×16 mm) 121 ℃ 16.9 minutes/134 ℃ 3.5 minutes/132 ℃ 4 minutes. Turns from yellow to dark brown/black. 100% lead free. ISO 11140-1 Type 2 ISO 11140-4.
Expand 1 Items
Bionova® 48 h Biological Indicator for Dry Heat
Supplier: TERRAGENE
Semi self-contained biological indicator for dry heat sterilization processes. Bacillus atrophaeus (ATCC 9372) 10⁶ spores per vial. Each box of 50 tubes. Readout: 48 hours. 25A+25B/BX.
Expand 1 Items
PASS/FAIL® Class 5 Process Challenge Pack, Propper Manufacturing
Supplier: Propper
PASS/FAIL® challenge pack is a disposable test pack for use in steam sterilizers.
Expand 1 Items
Chemdye® Three Line Automatic Labeler
Supplier: TERRAGENE
Three line labeler for quick and easy labeling of sterilization package with Chemdye® CD13/ CD23/ CD33/ CD43/ CD53/ CD73/ CD203/ CD403 labels.
Expand 1 Items
SPORTROL® Spore Suspensions
Supplier: Crosstex
Spore suspensions are pure suspensions of viable spores from specific organisms of known resistance to various sterilization processes.
Expand 2 Items
Bionova® Dual Incubator for Biological IndicaD23:D35
Supplier: TERRAGENE
Dual biological indicator Incubator. 37±2 or 60±2 °C.
Expand 1 Items
Dart® Daily Air Removal Test Pack, Steris
Supplier: Steris
The Dart® daily air removal test is a pre-assembled Bowie-Dick test pack products used in monitoring healthcare steam sterilizers.
Expand 2 Items
Bionova® 4 h Ethylene Oxide Sterilization Test Pack PCD Kit
Supplier: TERRAGENE
Process challenge device (KPCD110) for ethylene oxide sterilization processes. Bacillus atrophaeus (ATCC® 9372) 10⁶ spores per vial. Readout: 4 hours. 25PCD+25BI/BX.
Expand 1 Items
VERIFY™ Steam Integrator Strips, Steris
Supplier: Steris
Chemical integrators monitor all critical parameters of steam sterilization (time, temperature and steam quality).
Expand 2 Items
STERIL-PEEL™ Heat Seal Pouches, GS Medical Packaging
Supplier: GS Medical Packaging
All STERIL-PEEL™ products are manufactured from medical grade bleached kraft paper