You searched for: Multi-Element Standards
Claritas PPT® Grade Heavy Metals Testing Kit, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Heavy Metals & Minerals Testing Kits
For routinely analyzed Heavy Metals and Minerals
Heavy Metals and Minerals Testing Kits are designed for routinely analyzed heavy metals and minerals. All kits come with six, 30 ml standards which includes a nitiric acid blank for easy dilution. Conveniently packaged in a sturdy, heavy-duty carton, these kits are perfect to store on a lab bench or in a cabinet. The 30 ml standards ship non-hazardous, saving money on shipping costs. The smaller volume also allows for less hazardous waste should the standard expire before its contents are used.
Expand 1 Items
USP 232 Revision 40, Oral 3 Mix 1 Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
Instrument Calibration Standard 4, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
CLP Standards for ICP & ICP-MS
Expand 2 Items
USP 232 Revision 40, Inhalation 2B, Mix 2 Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
Calibration Standard for MSB, Thermo Scientific
Supplier: Thermo Scientific Chemicals
MDL No.: MFCD03792139
Expand 1 Items
Oral/Parenteral Elemental Impurities C, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
ICP Interferents A1, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
CLP Standards for ICP & ICP-MS
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.
The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.
US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:
• Exhibit C, Inorganic Target Analyte List (TAL)
• Exhibit D, Analytical Methods
• Exhibit E, QA/QC Requirements
CLP ISM 01.2 and ILM 05.2 & 05.3 Standards for ICP
For verification of inter-element and background correction factors at the beginning and the end of each analysis run. In addition, a verification must be done after every 20th sample. Two solutions are required for the most common interference check: Solution A, the interferents alone (INT-A1) and Solution AB, a combination of interferents (INT-A1) and analytes (INT-B3). Solution A is prepared by diluting INT-A1 20-fold. Solution AB is prepared by diluting INT-A1 20-fold and INT-B3 100-fold; for example, 5 ml of INT-A1 and 1 ml of INT-B3 into a 100 ml volumetric flask, brought to volume with a matrix blank. Once prepared, the solutions should be analyzed consecutively, starting with Solution A.
CLP ILM 02.0 Standards for ICP
For verification of inter-element and background correction factors at the beginning and the end of each analysis run. In addition, a verification must be done after every 20th sample. Two solutions are required for the most common interference check: Solution A, the interferents alone (INT-A1) and Solution AB, a combination of interferents (INT-A1) and analytes (INT-B1). Solution A is prepared by diluting INT-A1 20-fold. Solution AB is prepared by diluting INT-A1 20-fold and INT-B1 100-fold; for example, 5 ml of INT-A1 and 1 ml of INT-B1 into a 100 ml volumetric flask, brought to volume with a matrix blank. Once prepared, the solutions should be analyzed consecutively, starting with Solution A.
Expand 1 Items
ICP-MS Interferents A for 6020A ICS, Specpure®, Thermo Scientific
Supplier: Thermo Scientific Chemicals
Molecular Formula: Matrix: 2% HNO3/6.5% HCl/tr. HF C5
Physical Form: Liquid
UN No.: 3264
MDL No.: MFCD08064524
Expand 1 Items
USP 232 Revision 40, Oral 2A Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
Precious Metal Impurities B with Os, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
ICH Standard
Expand 2 Items
ICP-MS Tuning Standard solution for 200.8, Specpure®, Thermo Scientific
Supplier: Thermo Scientific Chemicals
Liquid
Expand 1 Items
ICP-MS Stock Standard solution A for 200.8, Rev. 5.4, Specpure®, Thermo Scientific
Supplier: Thermo Scientific Chemicals
Molecular Formula: Matrix: 5% HNO3/tr. tartaric acid
Physical Form: Liquid
UN No.: 3264
MDL No.: MFCD03792352
Expand 1 Items
Elemental Impurities E, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
ICH Standard
Expand 1 Items
USP 232 Revision 40, Inhalation 2B, Mix 1 Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
USP 232 Revision 40, Oral 2B Mix 1 Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
ICP-MS Interferents A1 and ICP-MS Analytes B1, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
CLP interference standards for ICP & ICP-MS.
Expand 2 Items
ICP-MS Internal Standard for 6020, Specpure®, Thermo Scientific
Supplier: Thermo Scientific Chemicals
Molecular Formula: Matrix: 5% HNO3
Physical Form: Liquid
UN No.: 3264
MDL No.: MFCD01868829
Expand 1 Items
USP 232 Revision 40, Inhalation Mix 1 Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
USP 232 Revision 40, Oral 2B Mix 2 Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
USP 232 Revision 40, Inhalation Mix 3 Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
USP 232 Revision 40, Oral 3 Mix 2 Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
Precious Metal Impurities B without Os, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
ICH Standard
Expand 2 Items
ICP-MS Tuning Standard solution for HP®, Specpure®, Thermo Scientific
Supplier: Thermo Scientific Chemicals
Molecular Formula: Matrix: 5% HNO3
Physical Form: Liquid
UN No.: 3264
MDL No.: MFCD00240453
Expand 1 Items
Claritas PPT® Grade Minerals Testing Kit, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® Grade Minerals Testing Kit for ICP-MS are designed for routinely analyzed minerals.
Expand 1 Items
ICP Quality Control Standards for EPA, Rev. 4.4 and 5.4, Inorganic Ventures
Supplier: Inorganic Ventures
These standards are designed for Rev. 4.4 and 5.4.
Expand 1 Items
ICP-MS Standard, Internal Standard, 6 analytes, Inorganic Ventures
Supplier: Inorganic Ventures
ICP-MS standard is a certified reference material set in a nitric acid matrix for stability.
Expand 1 Items
ICP-MS Quality Control Standards for EPA Method 200.7, Inorganic Ventures
Supplier: Inorganic Ventures
Quality Control Standard 26 is a certified reference material set in a nitric acid/hydrofluoric acid matrix for stability.
Expand 4 Items
AGI-ICP-MS Tuning Solution 1, Inorganic Ventures
Supplier: Inorganic Ventures
Certified reference material, traceable to NIST.