You searched for: Cationic Standards
Avantor offers a wide range of certified cationic standards designed for instrument calibration in ion-exchange chromatography (IC) applications, which can be applied toward environmental or food analysis and quality control. IC is an analytical technique used for the separation and quantification of anions and cations in aqueous samples. Avantor offers high-purity, well-defined reference materials ideal for low-ppm level quantification or trace analysis. Bottles of cationic standards are available for a range of elements.
ICP-MS Interferents A for 6020A ICS, Specpure®, Thermo Scientific
Supplier: Thermo Scientific Chemicals
Molecular Formula: Matrix: 2% HNO3/6.5% HCl/tr. HF C5
Physical Form: Liquid
UN No.: 3264
MDL No.: MFCD08064524
Expand 1 Items
ICP Spike Sample 4, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
CLP Standards for ICP & ICP-MS
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.
The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.
US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:
• Exhibit C, Inorganic Target Analyte List (TAL)
• Exhibit D, Analytical Methods
• Exhibit E, QA/QC Requirements
CLP ISM 01.2 and ILM 05.2 & 05.3 Standards for ICP
Our spike standard, SPIKE-4, provides all of the analytes required for the IC, ICP-AES and the AA spike.
Expand 1 Items
ICP Spike Sample 1, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
CLP Standards for ICP & ICP-MS
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.
The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.
US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:
• Exhibit C, Inorganic Target Analyte List (TAL)
• Exhibit D, Analytical Methods
• Exhibit E, QA/QC Requirements
CLP ILM 02.0 Standards for ICP
Our spike standard, SPIKE-1, provides all of the analytes required for the ICP-AES and the AA spike. Add 1 ml of SPIKE-1 to aqueous samples and 2 ml of SPIKE-1 to solid samples prior to digestion.
Expand 2 Items
ICP Alternate Interferents A, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
CLP Standards for ICP & ICP-MS
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.
The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.
US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:
• Exhibit C, Inorganic Target Analyte List (TAL)
• Exhibit D, Analytical Methods
• Exhibit E, QA/QC Requirements
Alternate Standards
We also provide a solution of alternate interferents and alternate analysis. Alternate interferents A (INT-A2) and alternate analytes B (INT-B2) may be prepared in combination with the INT-A1 and INT-B3 solutions mentioned, or any combination involving the four solutions, depending on the analytes and interferents of interest to you. We provides ICP-MS interferents and interferent check solutions for SW-845.
Expand 1 Items
Semiquantitative Standard 1, Specpure®, Thermo Scientific
Supplier: Thermo Scientific Chemicals
Liquid
Expand 2 Items
Assurance® Grade ICP Standards Kit, 38 Single-Element Standards, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Assurance® Grade, set of 38 single-element standards
Expand 1 Items
Instrument Calibration Standard 3, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
CLP Standards for ICP & ICP-MS
Expand 1 Items
ICP-MS Interferents B3 without Mercury, 2 µg/ml (2 ppm), SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
CLP Standards for ICP & ICP-MS
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.
The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.
US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:
• Exhibit C, Inorganic Target Analyte List (TAL)
• Exhibit D, Analytical Methods
• Exhibit E, QA/QC Requirements
CLP ISM 01.2 and ILM 05.2 & 05.3 Standards for ICP-MS
For verification of inter-element and background correction factors at the beginning and the end of each analysis run. In addition, a verification must be done after every 20th sample. Two solutions are required for the most common interference check: Solution A, the interferents alone (CL-INT-A2) and Solution AB, a combination of interferents (CL-INT-A2) and analytes (CL-INT-B3 or CL-INT-B4). Solution A is prepared by diluting CL-INT-A2 10-fold. Solution AB is prepared by diluting CL-INT-A2 10-fold and CL-INT-B3 or CL- INT-B4 100-fold; for example, 10 ml of CL-INT-A2 and 1 ml of CL-INT-B3 or CL-INT-B4 into a 100 ml volumetric flask, brought to volume with a matrix blank. Once prepared, the solutions should be analyzed consecutively, starting with Solution A.
Expand 1 Items
Heavy Metals, Plasma Standard Solution, Ag, As, Ba, Cd, Cr, Hg, Pb, Se
Supplier: BeanTown Chemical
EC No: 231-714-2
Expand 1 Items
USP 232 Revision 40, Parenteral 2B Mix 2 Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
Claritas PPT® Multi-Element Standards for ICP-MS, Set of 5 Multi-Element Instrument Check Standards, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® multi-element standards for ICP-MS
Expand 1 Items
Claritas PPT® Grade ICP-MS Internal Standard 1, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® Multi-Element Standards for ICP-MS.
Expand 1 Items
Claritas PPT® Grade ICP-MS Instrument Check Standard 5, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® multi-element standards for ICP-MS
Expand 1 Items
Assurance® Grade Drinking Water, Multi-Element Pollutant Standards with and without Mercury, for AA & ICP, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Drinking water pollutant standards. Assurance® mixed multi-element standards for AA & ICP.
Expand 2 Items
USP 232 Revision 40, Parenteral Mix 3 Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
Claritas PPT® Grade ICP-MS Alternate Internal Standard 2, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® Multi-Element Standards for ICP-MS.
Expand 1 Items
Assurance® Grade Instrument Check Standard 3 for AA & ICP, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Instrument check (Lab Performance) standards. Assurance® mixed multi-element standards for AA & ICP.
Expand 2 Items
Claritas PPT® Grade ICP-MS Alternate Internal Standard 1, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® Multi-Element Standards for ICP-MS.
Expand 2 Items
Claritas PPT® Grade ICP-MS Multi-Element Solution Standards Set without Mercury, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® multi-element standards for ICP-MS.
Expand 1 Items
Claritas PPT® Grade Multi-Element Standards for ICP-MS, set of 2 ICP-MS Memory Test Solution Set, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® multi-element standards for ICP-MS, memory test solutions.
Expand 1 Items
Claritas PPT® Grade ICP-MS Instrument Calibration Standard 3, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® Multi-Element Standards for ICP-MS. Tuning solutions are for ICP-MS instrumentation tuning and mass calibration prior to analysis.
Expand 1 Items
Claritas PPT® Grade ICP-MS Quality Control Standard 21, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® Multi-Element Standards for ICP-MS. Tuning solutions are for ICP-MS instrumentation tuning and mass calibration prior to analysis.
Expand 1 Items
Claritas PPT® Grade ICP-MS Initial Calibration Verification Standard 2, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® Multi-Element Standards for ICP-MS. Tuning solutions are for ICP-MS instrumentation tuning and mass calibration prior to analysis.
Expand 1 Items
Precious Metal Impurities B without Os, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
ICH Standard
Expand 2 Items
Assurance® Grade Mixed Calibration Standard 1 for AA and ICP, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Assurance® mixed multi-element standards for AA & ICP.
Expand 2 Items
Oral Elemental Impurities C, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
Parenteral Elemental Impurities D, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.