Titrators, potentiometric and volumetric, Titroline® 7750
The Titroline® 7750 is the all-rounder for both potentiometric titration and volumetric KF titration. The titrator combines the features of the potentiometric titrator TitroLine® 7000 and the volumetric Karl Fischer titrator TitroLine® 7500.
- Highly visible full colour display, that can be easily viewed from a distance and extreme angles
- With standard methods for potentiometric and KF titration and interchangeable modules (5, 10, 20 and 50 ml)
- System is easily expendable thanks to the USB and RS232 hosts
- Data storage of results (PDF and CSV format) including method transfer via USB port
: Unit supplied with stand rod and titration clamp Z 305, power supply 100 to 240 V and with or without magnetic stirrer.
- Catalog No:
- 661-1006
- 661-1007
- Model:
- Titroline® 7750
- Titroline® 7750
- Display:
- Graphic TFT display, 320×240 pixels
- Graphic TFT display, 320×240 pixels
- Keypad:
- Polyester coated
- Polyester coated
- Dosing accuracy:
- Accuracy: 0,15%
Precision: 0,05 - 0,07%
(depending on the interchangeable unit used) - Accuracy: 0,15%
Precision: 0,05 - 0,07%
(depending on the interchangeable unit used)
- Dosing volume:
- 5/10/20/50 ml
- 5 / 10 / 20 / 50 ml
- Burette resolution:
- 10000 steps
- 10000 steps
- Functions:
- Solution preparation, titration to mV and pH endpoints, dynamic and linear titration to inflection points (EQ) mV and pH, non aqueous titrations, 'dead stop' titration, pH-stat-titration, water determination according to KF volumetry
- Solution preparation, titration to mV and pH endpoints, dynamic and linear titration to inflection points (EQ) mV and pH, non aqueous titrations, 'dead stop' titration, pH-stat-titration, water determination according to KF volumetry
- pH range:
- −3...+18
- −3...+18
- pH accuracy:
- 0,002 ±1 digit (without sensor)
- 0,002 ±1 digit (without sensor)
- pH resolution:
- 0,001
- 0,001
- mV range:
- ±2000
- ±2000
- mV resolution:
- 0,1
- 0,1
- Measuring input electrode:
- pH / mV electrode with DIN or BNC socket; double-platinum electrode (µA)
- pH / mV electrode with DIN or BNC socket; double-platinum electrode (µA)
- mV accuracy:
- 0,1 ±1 digit
- 0,1 ±1 digit
- Measuring input PT1000:
- Temperature sensor PT1000 (connection sockets 2×4 mm)
- Temperature sensor PT1000 (connection sockets 2×4 mm)
- Connections:
- 2× USB-A, 1× USB-B, 2× RS232
- 2× USB-A, 1× USB-B, 2× RS232
- Operating temperature:
- 10...40 °C
- 10...40 °C
- W×D×H:
- 153×296×450 mm
- 153×296×450 mm
- Weight:
- 2,3 kg
- 2,3 kg
Frequently Bought Together