Order Entry
United Kingdom
ContactUsLinkComponent
 

You searched for: Chromatography Standards

Frequently used for calibration, the chromatography standards have a known concentration to test separating equipment for performance faults. Analytical equipment error would impact the dependability of retention time, purity, molecular weight, and compound identification conclusions. Improving data quality, the substances allow personnel to plot analyte signal ratios and obtain concentrations from a calibration curve. Chromatography standards verify instruments are suitable for intended ion exchange, gel filtration, and hydrophobic interaction procedures.

Poly(methacrylic acid sodium salt) analytical standards, for GPC, Supelco®

Supplier: Merck

GPC Standard, ~483000 Mw, Mw/Mn ~1,12, Supelco®

Expand 3 Items
Loading...

Poly(dimethylsiloxane), average Mw 95000 (Typical), average Mn 50000 (Typical), analytical standard, Supelco®

Supplier: Merck

GPC Standard, Poly(dimethylsiloxane), average Mw 95000 (Typical), average Mn 50000 (Typical), Supelco®, Analytical standard

Expand 1 Items
Loading...

Poly(α-methylstyrene) analytical standards, for GPC

Supplier: Merck

Poly(α-methylstyrene) may find applications as a radical producing agent, in the thermal degradation of polystyrene.

Expand 3 Items
Loading...

Nucleosides test mix, analytical standard, Supelco®

Supplier: Merck

HPLC Standard, Nucleosides Test Mix, Supelco®, in 1% sodium formate (varied conc.), Analytical standard, Pk Info: ampule of 1 mL

Expand 1 Items
Loading...

Poly(lauryl methacrylate) solution, Mw 570000 (Typical), average Mn 290000 (Typical), analytical standard, Supelco®

Supplier: Merck

GPC Standard, Poly(lauryl methacrylate) solution, Mw 570000 (Typical), average Mn 290000 (Typical), Supelco®, 25 wt. % in toluene, Analytical standard

Expand 1 Items
Loading...

Poly(ethylene glycol) analytical standards, for GPC, Supelco

Supplier: Merck

Poly(ethylene glycol) is the most widely used non-ionic, hydrophilic polymer, which can find wide applications in biomedical industry such as in drug delivery systems.

Expand 1 Items
Loading...

Polystyrene, average Mw 290000 (typical), average Mn 130000 (typical), analytical standard, Supelco®

Supplier: Merck

GPC Standard, Polystyrene, average Mw 290000 (typical), average Mn 130000 (typical), Supelco®, Analytical standard

Expand 1 Items
Loading...

Reversed phase test mix, in methanol: water (3:2) (varied conc.), certified reference material, Supelco®

Supplier: Merck

HPLC Standard, Reversed Phase Test Mix, in methanol: water (3:2) (varied conc.), TraceCERT®, Supelco®, Certified reference material, Pk Info: ampule of 1 mL

Expand 1 Items
Loading...

Poly(styrenesulfonic acid sodium salt) analytical standards for GPC

Supplier: Merck

GPC Standard, ~4300 Mw, Mw/Mn ~1,2, Supelco®

Expand 8 Items
Loading...

Poly(methyl methacrylate) PMMA, analytical standard, for GPC

Supplier: Merck

Poly(methyl methacrylate) is a rigid and transparent type of polymer material. It is obtained via polymerization of methyl methacrylate monomer.

Expand 10 Items
Loading...

Poly(vinyl chloride), average Mw 85000 (Typical), average Mn 40000 (Typical), analytical standard, Supelco®

Supplier: Merck

GPC Standard, Poly(vinyl chloride), average Mw 85000 (Typical), average Mn 40000 (Typical), Supelco®, Analytical standard

Expand 1 Items
Loading...

Polystyrene standard ReadyCal set Mp 400-2000000, analytical standards for GPC

Supplier: Merck

Set contains 12 different polystyrene standards with Mp ~374, ~1620, ~3420, ~9130, ~18100, ~32500, ~67500, ~128000, ~246000, ~659000, ~1000000, ~2180000; always 4 standards are lyophilised in a 1,5 ml vial (green, red or white); for 1 complete calibration use one of each of the green, red and white vials; 1 set contains 30 vials for 10 complete calibrations.

Expand 1 Items
Loading...

HPLC standards, LiChroTest®, Supelco®

Supplier: Merck

Standard samples for HPLC System Qualification.

Expand 6 Items
Loading...

Polyethylene glycol Standard ReadyCal Set Mp 200-1200000, for GPC, Supelco

Supplier: Merck

Set contains 10 different polyethylene glycol/polyethylene oxide standards with Mp ~194, ~970, ~2010, ~4450, ~15000, ~22100, ~62000, ~217000, ~490000, ~1190000; always 3 or 4 standards are lyophilised in a 1,5 ml vial (black, blue or yellow); for 1 complete calibration use one of each of the black, blue and yellow vials; 1 set contains 30 vials for 10 complete calibrations.

Expand 1 Items
Loading...

Poly(acrylic acid), average Mn 130000 (Typical), analytical standard, Supelco®

Supplier: Merck

GPC Standard, Poly(acrylic acid), average Mn 130000 (Typical), Supelco®, Analytical standard

Expand 1 Items
Loading...

Poly(butyl acrylate) solution, Mw 60000 (Typical), average Mn 20000 (Typical), analytical standard, Supelco®

Supplier: Merck

GPC Standard, Poly(butyl acrylate) solution, Mw 60000 (Typical), average Mn 20000 (Typical), Supelco®, 25 wt. % in toluene, Analytical standard

Expand 1 Items
Loading...

Peptide and protein MALDI-MS calibration kit, ProteoMass™, Supelco®

Supplier: Merck

This kit features a convenient selection of pre-qualified standard peptides, proteins, matrices, and solvents for calibrating and testing matrix assisted laser desorption ionisation (MALDI) mass spectrometers.

Expand 1 Items
Loading...

HPLC isocratic systems diagnostics mix, in methanol: water (3:2) (varied concentration), certified reference material, Supelco®

Supplier: Merck

This formulation is designed for evaluating how reliably a chromatographic system is providing such fundamentally important parameters as flow rate, proportioning, and mixing.

Expand 1 Items
Loading...

Poly(acrylic acid sodium salt) analytical standards, for GPC

Supplier: Merck

Poly(acrylic acid sodium salt) is a hydrophilic polymer, which can find wide applications in the production of consumer product like diapers, because of its ability to absorb many more times its mass in water.

Expand 3 Items
Loading...

HPLC gradient system diagnostics mix, in methanol: water (3:2) (varied concentration), certified reference material, Supelco®

Supplier: Merck

This formulation is designed for evaluating how reliably a chromatographic system is providing such fundamentally important parameters as flow rate, proportioning, and mixing.

Expand 1 Items
Loading...

Polar column test mix, certified reference material, Supelco®

Supplier: Merck

Polar Column Test Mix, TraceCERT®, Supelco®, 500 mug/mL each component in dichloromethane, Certified reference material, Pk Info: ampule of 2 mL

Expand 1 Items
Loading...

Poly(Bisphenol A carbonate) analytical standards kit, molecular weight series, for GPC

Supplier: Merck

Poly(Bisphenol A carbonate) (PC) is a thermoplastic material. It is injected in molding operations and is majorly studied to understand its thermal behaviour, especially thermal degradation property.

Expand 1 Items
Loading...

Nonpolar column test mix, certified reference material, Supelco®

Supplier: Merck

Nonpolar Column Test Mix, TraceCERT®, Supelco®, 500 mug/mL in dichloromethane, Certified reference material, Pk Info: ampule of 2 mL

Expand 1 Items
Loading...

Polyethylene glycol Standard ReadyCal Set Mp 102-40′000, for GPC

Supplier: Merck

Set contains 12 different polyethyleneglycol standards with Mp ~106, ~330, ~420, ~600, ~1500, ~2010, ~3120, ~6240, ~8600, ~12000, ~23000, ~40000; always 4 standards are lyophilised in a 1,5 ml vial (green, red or white); for 1 complete calibration use one of each of the green, red and white vials; 1 set contains 30 vials for 10 complete calibrations

Expand 1 Items
Loading...
Reference substances for GC analysis, Supelco®

Reference substances for GC analysis, Supelco®

Supplier: Merck

Reference substances can be used for the identification of unknown compounds in a gas chromatogram or as standards in quantitative GC analysis. They serve also for the characterisation of GC column properties.

Expand 3 Items
Loading...

Poly(dimethylsiloxane) analytical standard, for GPC

Supplier: Merck

Poly(dimethylsiloxane) [PDMS] is a polymer. It is a stable silicone rubber. It has been used as ion selective membrane for ion-sensitive field-effect transistors, as spring material in accelerometers, elastomer on a tactile sensor and as flexible encapsulation material in decouple sensors.

Expand 1 Items
Loading...

Programmed test mix, in dichloromethane (varied conc.), certified reference material, Supelco®

Supplier: Merck

This test mix is based on the comprehensive mix developed by Grob (Grob, et al., J. Chromatogr. 156 (1978) p. 1)

Expand 1 Items
Loading...

MALDI validation set polystyrene Mp ~700 - 70000, certified reference material, Supelco®

Supplier: Merck

MALDI Standards are suitable for the validation and comparison of MALDI-ToF instruments. Certificates provide MALDI spectra including Mw, Mn and Mp values of select narrow polymers, which differ in molar mass.

Expand 1 Items
Loading...

Standards for saturated/monounsaturated fatty acids, LC-MS mixture

Supplier: Cayman Chemical

Saturated or monounsaturated fatty acid LC-MS mixture contains various saturated or unsaturated fatty acids. The mixture is supplied in an amber ampule in which the headspace has been purged with argon to prevent lipid oxidation. This product has been designed for direct use in LC-MS applications.

Expand 1 Items
Loading...

Polystyrene (low molecular) Standard ReadyCal Set M(p) 250-70000 for GPC

Supplier: Merck

Set contains 12 different polystyrene standards with Mp ~266, Mp ~374, Mp~1100, Mp~1920, Mp~2950, Mp ~4870, Mp ~7200, Mp~10400, Mp ~15700, Mp ~19600, Mp ~34800, Mp ~67500; always 4 standards are lyophilised in a 1,5ml vial (yellow, blue or black); for 1 complete calibration use one of each of the yellow, blue and black vials; 1 set contains 30 vials for 10 complete calibrations.

Expand 1 Items
Loading...
Recommended for You