2381 Results for: "GC Columns"
Chromosorb PAW 10 % OV-101, 80/100, preconditioned, 41.28 mm coil, 2 feet (0.61 m) x 1/8 inch, 2.1 mm, UltiMetal, packed GC column, for large valve oven 1 * 1 items
Supplier: Agilent
Chromosorb PAW 10 % OV-101, 80/100, preconditioned, 41.28 mm coil, 2 feet (0.61 m) x 1/8 inch, 2.1 mm, UltiMetal, packed GC column, for large valve oven 1 * 1 items
Expand 1 Items
Chromosorb PAW 12% UC W982, 80/100, preconditioned, 25 mm coil, 2 feet (0.61 m) x 1/8 inch, 2.1 mm, UltiMetal, packed GC column, for Large Valve Oven 1 * 1 items
Supplier: Agilent
Chromosorb PAW 12% UC W982, 80/100, preconditioned, 25 mm coil, 2 feet (0.61 m) x 1/8 inch, 2.1 mm, UltiMetal, packed GC column, for Large Valve Oven 1 * 1 items
Expand 1 Items
Thermolite® septa
Supplier: Restek
These septa are preconditioned and ready to use.
Expand 15 Items
GC capillary column ROTI®CAP-WAX Polyethyleneglycol (PEG) 20000 Daltons • Polar • recommended for the solvent analytics of alcohols • suitable for aequous solutions • high temperature stability Length:,,30 m Ø interior 0,25 mm layer thickness 0,25 µm 1 * 1 items
Supplier: Roth Carl
GC capillary column ROTI®CAP-WAX Polyethyleneglycol (PEG) 20000 Daltons • Polar • recommended for the solvent analytics of alcohols • suitable for aequous solutions • high temperature stability Length:,,30 m Ø interior 0,25 mm layer thickness 0,25 µm 1 * 1 items
Expand 1 Items
Gas Chromatograph with FID (GC-FID)
Supplier: LUCIDITY
Compact, economical, fully functional gas chromatograph.
Expand 1 Items
One-piece front and back ferrules, GVF
Supplier: Trajan Scientific and Medical
These ferrules are made from 15% graphite and 85% Vespel®. They have a temperature limit of 350 °C and cannot be re-used with another capillary column.
Expand 4 Items
Backpressure regulator kit
Supplier: Restek
This backpressure regulator kit increases the versatility of Agilent 5890 GC by replacing the existing 0,06 bar (207 kPa) backpressure regulator and gauge with a 4,14 bar regulator.
Expand 1 Items
Capillary installation gauges
Supplier: Restek
These capillary installation gauges for Agilent GCs are made from high-quality stainless steel.
Expand 4 Items
Gas purifiers
Supplier: Trajan Scientific and Medical
Gas purifiers are designed to provide fast stabilisation times to reduce gas consumption and provide clean gas to GC and GC/MS systems.
Expand 8 Items
Ferrules, GRAPHPACK®
Supplier: Restek
GRAPHPACK® technology provides a complete system that quickly and reliably makes a leak-tight, low-dead-volume connection.
Expand 2 Items
Capillary tubing
Supplier: Trajan Scientific and Medical
Non deactivated fused silica capillary tubing.
Used in a wide range of capillary GC, HPLC and bioanalytical applications
Made from high quality fused silica
Tubing protected with a high temperature polyimide resin
Expand 72 Items
Gas clean purification system
Supplier: Agilent
The Gas Clean Filter System delivers clean gases, reducing the risks of column damage, sensitivity loss, and instrument downtime.
Expand 1 Items
Ferrules for gas chromatography
Supplier: VARIAN
Vespel/graphite and precision graphite ferrules for chromatography applications.
Expand 5 Items
Inlet base seals
Supplier: Thermo Fisher Scientific
Ideal for analysis of active compounds such as pesticides, polychlorinated biphenyls (PCBs) and phenol.
Expand 3 Items
Capillary adaptable FID jet
Supplier: Restek
These capillary adaptable FID replacement jets are engineered with a fluted tip to guide the capillary column into the jet.
Expand 4 Items
Capillary tubings, stainless steel, J&W UltiMetal plus
Supplier: VARIAN
UltiMetal Plus Stainless Steel Capillary Tubing products are the preferred choice for most applications due to its inertness and robustness.
Expand 7 Items
SGE OptChem™ Tapered FocusLiner Inlet Liners
Supplier: Trajan Scientific and Medical
The SGE inlet liner range aims to make it simple for all gas chromatographers to select the correct liner. Choosing the right inlet liner and injection parameters can increase peak areas and reduce detection limits by up to 300%.
Expand 4 Items
Fragrance allergen standards kit
Supplier: Restek
Ideal for GC-MS analysis following IFRA methodology.
Expand 1 Items
Gas purifiers/filters, Big Trap
Supplier: Trajan Scientific and Medical
Big Trap gas purifiers are designed for bulk purification applications, or where several instruments are plumbed from a single source.
Expand 8 Items
Long-Chain Cis/Trans Isomer Fatty Acid Methyl Ester Mixture
Supplier: Cayman Chemical
Long-chain cis/trans isomer fatty acid methyl ester mixture contains cis and trans isomers of several fatty acids. It is intended for use as a reference standard for the detection of long-chain fatty acids in various sample types by GC-MS.
Expand 1 Items
Gas filter connecting units
Supplier: Trajan Scientific and Medical
A connecting unit with inlet and outlet connectors for the gas lines.
Expand 8 Items
One-piece front and back ferrules, OGF
Supplier: Trajan Scientific and Medical
These reusable ferrules are made from 100% graphite. They have a temperature limit of 450 °C.
Expand 25 Items
SGE OptChem™ Double Taper Inlet Liners
Supplier: Trajan Scientific and Medical
The SGE inlet liner range aims to make it simple for all gas chromatographers to select the correct liner.
Expand 3 Items
SGE OptChem™ ConnecTite Inlet Liners
Supplier: Trajan Scientific and Medical
The SGE inlet liner range aims to make it simple for all gas chromatographers to select the correct liner.
Expand 6 Items
Fragrance materials test mix (12 components)
Supplier: Restek
This fragrance materials test mix idela to performance evaluation for essential oils and fragrance chemicals.
Expand 1 Items
Rethreading tool
Supplier: Restek
These rethreading tools are suitable for repairing worn or damaged threads that come as a result of consistent use and temperature changes.
Expand 4 Items
Organochlorine pesticide system evaluation mix (2 components)
Supplier: Restek
Contains two components, those are 4,4'-DDT and endrin.
Expand 1 Items
GC septa, low bleed high temperature
Supplier: HAMILTON BONADUZ
Low bleed high temperature septa are designed for the lowest bleed possible at temperatures of up to 400 °C. They can be used in combination with Mass Spectrometers or in applications where septa bleed interferes with trace analysis. These septa are typically used for manual injection applications.
Expand 9 Items
EFSA PAH4 Standard
Supplier: Restek
Organic Standard, EFSA PAH4 Standard,1 ml/Ampule
Expand 1 Items
UHP nitrogen generator, NG5000
Supplier: PEAK SCIENTIFIC
The NG5000 delivers ultra high purity nitrogen at trace detection limits through Pressure Swing Adsorption technology at flows of up to 5 L/min for GC, DSC and DMA applications as well as other laboratory. This generator requires a high quality source of in-house air to supply the unit.