Order Entry
Slovenia
ContactUsLinkComponent
11477 results for "4-Chlorobutane-1-sulphonyl+chloride"

11477 Results for: "4-Chlorobutane-1-sulphonyl+chloride"

Titrators, Karl Fisher, EasyPlus™

Supplier: Mettler - Toledo

This versatile titrator is suitable for a range of determinations making it ideal for simple titrations of most sample types. The simple 'App' style user interface reduces training time while increasing work speed and simplicity. iTitrate Intelligence’s guided set-up assists in method programming to ensure samples are tested consistently, regardless of operator, and with minimal effort. Ideal for KF titrations of a wide range of samples from any industry.

Expand 1 Items
Loading...
SOM01.1 SVOA MegaMix standard, revised (65 components)

SOM01.1 SVOA MegaMix standard, revised (65 components)

Supplier: Restek

Consists of 65 components, those are acenaphthene, acenaphthylene, acetophenone, anthracene, benzanthracene, benzopyrene, benzofluoranthene, benzoperylene, benzofluoranthene, benzyl butyl phthalate, biphenyl, bismethane, bisether, bisphthalate, 4-bromophenyl-phenylether, carbazole, 4-chloroaniline, 4-chloro-3-methylphenol, 2-chloronaphthalene, 2-chlorophenol, 4-chlorophenyl-phenylether, chrysene, dibenzanthracene, dibenzofuran, 3,3'-dichlorobenzidine, 2,4-dichlorophenol, diethylphthalate, 2,4-dimethylphenol, dimethylphthalate, di-n-butylphthalate, 4,6-dinitro-2-methylphenol , 2,4-dinitrophenol, 2,4-dinitrotoluene, 2,6-dinitrotoluene, di-n-octyl phthalate, diphenylamine *,fluoranthene, fluorene, hexachlorobenzene, hexachloro-1,3-butadiene , hexachlorocyclopentadiene, hexachloroethane, indenopyrene, isophorone, 2-methylnaphthalene, 2-methylphenol , 3-methylphenol, 4-methylphenol , naphthalene, 2-nitroaniline, 3-nitroaniline, 4-nitroaniline, nitrobenzene, 2-nitrophenol, 4-nitrophenol, n-nitroso-di-n-propylamine, 2,2'-oxybis, pentachlorophenol, phenanthrene, phenol, pyrene, 1,2,4,5-tetrachlorobenzene, 2,3,4,6-tetrachlorophenol, 2,4,5-trichlorophenol and 2,4,6-trichlorophenol.

Expand 1 Items
Loading...

Anti-ANO1 Mouse Monoclonal Antibody [clone: DG1/1486]

Supplier: ProSci Inc.

Expression of DOG-1 protein is elevated in the gastrointestinal stromal tumors (GIST s), c-kit signaling-driven mesenchymal tumors of the GI tract. DOG-1 is rarely expressed in other soft tissue tumors, which, due to appearance, may be difficult to diagnose. Immunoreactivity for DOG-1 has been reported in 97.8 percent of scorable GIST s, including all c-kit negative GIST s. Overexpression of DOG-1 has been suggested to aid in the identification of GISTs, including Platelet-Derived Growth Factor Receptor Alpha mutants that fail to express c-kit antigen. The overall sensitivity of DOG1 and c-kit in GIST s is nearly identical: 94,4% vs. 94,7%.

Expand 1 Items
Loading...

Chromium(III) potassium sulphate dodecahydrate, black crystals ACS

Supplier: MP Biomedicals

Chromium potassium sulfate is the potassium double sulfate of chromium.

Expand 1 Items
Loading...

AlbumiNZ™ Bovine serum albumin (BSA), MP Biomedicals

Supplier: MP Biomedicals

Albumins are a group of acidic proteins which occur in the body fluids and tissues of mammals and in some plant seeds. Serum and plasma albumin is carbohydrate-free and comprises 55 to 62% of the protein present. However, only about 40% of the total albumin in the body is in the circulating plasma at one time with the remainder being in extracellular spaces with which there is, in general, equilibration about every 24 hours.

Expand 1 Items
Loading...
VWR® VisiScope® IT600 FLD, Fluorescence Microscope, Inverted Trinocular

VWR® VisiScope® IT600 FLD, Fluorescence Microscope, Inverted Trinocular

Supplier: VWR Collection

Routine inverted fluorescence microscopes for transmitted brightfield, darkfield, phase contrast and fluorescence observations. Ideal for tissue culture research in clinical and biotechnology laboratories.

Expand 1 Items
Loading...
pH combination electrodes, Orion™ 8102BN ROSS™

pH combination electrodes, Orion™ 8102BN ROSS™

Supplier: Thermo Orion

ROSS pH electrodes offer unmatched benefits that users will not find in any other pH electrode. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...

Combination pH electrode, Orion™ 815600 ROSS™

Supplier: Thermo Orion

ROSS pH electrodes offer unmatched benefits that users will not find in any other pH electrode. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...

Anti-ANO1 Mouse Monoclonal Antibody [clone: tDAN4]

Supplier: ProSci Inc.

Expression of TMEM16A (DOG1) protein is elevated in the gastrointestinal stromal tumors (GIST’s), c-kit signaling-driven mesenchymal tumors of the GI tract. It is rarely expressed in other soft tissue tumors, which, due to appearance, may be difficult to diagnose. Immunoreactivity for DOG11 has been reported in 97,8 percent of scorable GIST’s, including all c-kit negative GIST’s. Overexpression has been suggested to aid in the identification of GISTs, including Platelet-Derived Growth Factor Receptor Alpha (PDGFR alpha) mutants that fail to express c-kit antigen. The overall sensitivity of TMEM16A and c-kit in GIST’s is nearly identical: 94,4% vs. 94,7%.

Expand 1 Items
Loading...
pH electrode, half-cell, Orion™ ROSS™ 8101BNWP

pH electrode, half-cell, Orion™ ROSS™ 8101BNWP

Supplier: Thermo Orion

This half-cell electrode provides stable readings to 0,01 pH in less than 30 seconds. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...

Anti-ANO1 Mouse Monoclonal Antibody [clone: SPM580]

Supplier: ProSci Inc.

Expression of DOG-1/ANO1/TMEM16A protein is elevated in the gastrointestinal stromal tumors (GISTs), c-kit signaling-driven mesenchymal tumors of the GI tract. ANO1 is rarely expressed in other soft tissue tumors, which, due to appearance, may be difficult to diagnose. Immunoreactivity has been reported in 97.8 percent of scorable GISTs, including all c-kit negative GISTs. Overexpression has been suggested to aid in the identification of GISTs, including Platelet-Derived Growth Factor Receptor Alpha mutants that fail to express c-kit antigen. The overall sensitivity of DOG-1/ANO1 and c-kit in GISTs is nearly identical: 94,4% vs. 94,7%.

Expand 1 Items
Loading...
Safety wash bottles, right-to-understand, Nalgene®

Safety wash bottles, right-to-understand, Nalgene®

Supplier: Thermo Fisher Scientific

Narrow, cylindrical FEP bottle with ETFE dispensing cap. New globally harmonised chemical labeling rules have been enacted to protect workers who come into contact with hazardous chemicals.

   Sustainable Options Available
Expand 6 Items
Loading...
Orion™ Lab Star PH111 Bench pH Meters

Orion™ Lab Star PH111 Bench pH Meters

Supplier: Thermo Orion

Measure pH or ORP simultaneously with mV and temperature using the Orion Lab Star PH111 pH/mV meter. Featuring a large, backlit display for easy viewability and small footprint to save bench space, this pH meter is ideal for simplified, budget-friendly lab testing. Use the onscreen stabilizing and ready indicators to help identify when pH meter and ORP meter readings are complete. View active pH, ORP and temperature calibration logs with date and time stamp, record key measurements using the 500-point data log with date and time stamp, and output all logs to a printer or computer.

Expand 5 Items
Loading...

Anti-ANO1 Mouse Monoclonal Antibody [clone: DG1/447]

Supplier: ProSci Inc.

Expression of TMEM16A (DOG1) protein is elevated in the gastrointestinal stromal tumors (GIST’s), c-kit signaling-driven mesenchymal tumors of the GI tract. It is rarely expressed in other soft tissue tumors, which, due to appearance, may be difficult to diagnose. Immunoreactivity for TMEM16A has been reported in 97,8 percent of scorable GIST’s, including all c-kit negative GIST’s. Overexpression has been suggested to aid in the identification of GISTs, including Platelet-Derived Growth Factor Receptor Alpha (PDGFR alpha) mutants that fail to express c-kit antigen. The overall sensitivity of TMEM16A and c-kit in GIST’s is nearly identical: 94,4% vs. 94,7%.

Expand 1 Items
Loading...
Hot melt adhesive 3764, 3M™

Hot melt adhesive 3764, 3M™

Supplier: 3M

The 3M™ Hot Melt Adhesive 3764 is a clear, 100% solids thermoplastic adhesive capable of bonding to many plastics, including polyolefin. Formulated to be flexible at low temperatures, this hot melt adhesive is designed to deliver exceptional performance for a wide range of applications and industries.

Expand 1 Items
Loading...
Pierce™ BupH™ Wash Buffers, Dry Blend Pack

Pierce™ BupH™ Wash Buffers, Dry Blend Pack

Supplier: Thermo Fisher Scientific

BupH packs are pre-blended and pre-measured dry mixtures of buffers that are easy to prepare and used in protein purification and common laboratory techniques.

Expand 8 Items
Loading...
Combination pH electrodes, semi-micro, Orion™ 8103BN ROSS™

Combination pH electrodes, semi-micro, Orion™ 8103BN ROSS™

Supplier: Thermo Orion

These pH electrodes with semi-micro tip are ideal for use in clinical, pharmaceutical, and food labs, wherever sample size is a constraint. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...
pH electrode, Orion™ 8156BNUWP ROSS Ultra™

pH electrode, Orion™ 8156BNUWP ROSS Ultra™

Supplier: Thermo Orion

This top performance pH electrode can be used to precisely perform pH determinations. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...
Orion Star™ T940 All-in-One Titrators

Orion Star™ T940 All-in-One Titrators

Supplier: Thermo Orion

Use the Orion Star T940 all-in-one titrator for flexible pH, redox and ion concentration titrations including equivalence point titrations, preset pH or mV endpoint titrations plus multiple known addition (MKA) mode for automated known addition of various ions.

Expand 3 Items
Loading...
Trypan blue 0.4% in PBS, dark blue solution

Trypan blue 0.4% in PBS, dark blue solution

Supplier: MP Biomedicals

Trypan Blue is a blue acid dye with a strong affinity for cellulose containing substrates such as cotton; less affinity for proteinaceous materials. Trypan blue solution may be used in trypan blue based cytotoxicity and proliferation assays.
Trypan Blue is used as a vital dye which is especially important because it is taken up by the reticuloendothelial system.

Expand 1 Items
Loading...
pH electrode, Orion™ 8102BNUWP ROSS Ultra™

pH electrode, Orion™ 8102BNUWP ROSS Ultra™

Supplier: Thermo Orion

This general purpose combination electrode with toughened bulb and top-performance glass body can be used for precise pH determinations. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...
pH combination electrode, semi-micro, Orion™ 8115BNUWP ROSS Ultra™

pH combination electrode, semi-micro, Orion™ 8115BNUWP ROSS Ultra™

Supplier: Thermo Orion

This durable combination pH electrode with semi-micro tip helps users to measure pH in micro volume aqueous solutions. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...
pH electrode, Orion™ 8165BNWP ROSS™ Sure-Flow™

pH electrode, Orion™ 8165BNWP ROSS™ Sure-Flow™

Supplier: Thermo Orion

This pH electrode is ideal for meaurement in thick or viscous samples, but compatible with all sample types. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...
Combination pH electrodes with flat surface tip, Orion™ 8135 ROSS™

Combination pH electrodes with flat surface tip, Orion™ 8135 ROSS™

Supplier: Thermo Orion

The ROSS combination flat surface pH electrodes measure pH of soft, moist surfaces — both solid and semi-solid — such as agar gel plates, meats, bread dough and similar samples. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...
pH combination electrode, Orion™ ROSS Ultra™ refillable pH/ATC Triode™

pH combination electrode, Orion™ ROSS Ultra™ refillable pH/ATC Triode™

Supplier: Thermo Orion

This electrode with built-in temperature sensor is ideal for any application where the use of metallic reference electrodes would contaminate the samples. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...
Combination pH electrode, spear tip, Orion™ 8163BNWP ROSS™

Combination pH electrode, spear tip, Orion™ 8163BNWP ROSS™

Supplier: Thermo Orion

Its spear tip makes this electrode ideal for pH measurement in semi-solid food material such as cheese, meat, fruit, bread and other similar samples. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...
pH electrode, Orion™ 8104BNUWP ROSS Ultra™

pH electrode, Orion™ 8104BNUWP ROSS Ultra™

Supplier: Thermo Orion

This general purpose combination electrode with toughened bulb and top-performance glass body can be used for precise pH determinations. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...
Combination pH micro electrode, Orion™ PerpHecT™ ROSS™

Combination pH micro electrode, Orion™ PerpHecT™ ROSS™

Supplier: Thermo Orion

This pH electrode is ideal for measuring micro volume samples. A PTFE protective sleeve over the glass stem provides greater durability than conventional micro pH electrodes and allows pH and temperature measurement of samples in 384 well plates or samples.
Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...
Orion™ ROSS Ultra™ Triode™ pH/ATC Combination Electrode

Orion™ ROSS Ultra™ Triode™ pH/ATC Combination Electrode

Supplier: Thermo Orion

This Triode™ electrode has a built-in temperature sensor allowing users to measure pH and temperature with only one electrode. Ideal for complex samples, such as biological media, foods and pharmaceuticals. Compared to conventional electrodes, the proven ROSS reference system exhibits superior stability in measurements, faster response, greater accuracy and precision when measuring samples that vary in temperature or when calibrating in temperatures that differ from the samples.

Expand 1 Items
Loading...

White to off-white powder. 1 * 100 g

Supplier: MP Biomedicals

White to off-white powder. 1 * 100 g

Expand 1 Items
Loading...
Recommended for You