UV/Vis Calibration Standards
About this item
The Hellma® calibration standards comply with all necessary standards and regulations and thus offer the highest quality for recalibrating your spectrometer.
DAkkS calibration certificate*
- 30-year warranty
- All sets including relevant reference
- Traceable to NIST or PTB
- Resource-saving and sustainable
-
Compliant
Center height: 8,5 to 20 mm
Exterior dimension (H×W×D):45×12,5×12,5 mm
Hellma® calibration standards are 100% manufactured in Germany.
Compliant: The Hellma® calibration standards comply with the specifications of quality management. systems and pharmacopoeias (e.g. Ph. Eur. and USP) for the highest quality requirements and international comparability of the measurement results.
DAkkS calibration certificate*: Hellma® calibration standards are manufactured in the Hellma Analytics calibration laboratory, which is accredited by DAkkS* according to DIN EN ISO/IEC 17025, and are delivered with a DAkkS calibration certificate*.
Traceability: All measurement results of the Hellma® calibration standards can be traced back to calibration standards measured by the NIST (National Institute of Standards and Technology for Photometric Accuracy) or the PTB (Physikalisch-Technische Bundesanstalt für die Wellenlängengenauigkeit).
Resource-saving and sustainable: Hellma® calibration standards can be easily reused for years and remain in use for a long time. There is no need for repetitive, time-consuming preparation and production of calibration solutions, thus conserving resources, the environment and budget. A sustainable and environmentally friendly alternative!
30-year warranty: We trust in our quality and you can rely on reliable measurement results! If you recalibrate regularly – at least every two years – in the Hellma Analytics calibration laboratory, you will receive a 30-year manufacturer's warranty on all Hellma® calibration standards.
*) Note: Calibration laboratory accredited by DAkkS according to DIN EN ISO/IEC 17025. The accreditation is only valid for the scope of accreditation listed in the document annex D-K-18752-01-00.
Certifications: NIST SRM 1930, European Pharmacopoeia, USP 857.
Delivery information: The set, along with an empty mount, is supplied in a sturdy carrying case.
22 Options Available Below
Product Details & Documents
The Hellma® calibration standards comply with all necessary standards and regulations and thus offer the highest quality for recalibrating your spectrometer.
DAkkS calibration certificate*
- 30-year warranty
- All sets including relevant reference
- Traceable to NIST or PTB
- Resource-saving and sustainable
-
Compliant
Center height: 8,5 to 20 mm
Exterior dimension (H×W×D):45×12,5×12,5 mm
Hellma® calibration standards are 100% manufactured in Germany.
Compliant: The Hellma® calibration standards comply with the specifications of quality management. systems and pharmacopoeias (e.g. Ph. Eur. and USP) for the highest quality requirements and international comparability of the measurement results.
DAkkS calibration certificate*: Hellma® calibration standards are manufactured in the Hellma Analytics calibration laboratory, which is accredited by DAkkS* according to DIN EN ISO/IEC 17025, and are delivered with a DAkkS calibration certificate*.
Traceability: All measurement results of the Hellma® calibration standards can be traced back to calibration standards measured by the NIST (National Institute of Standards and Technology for Photometric Accuracy) or the PTB (Physikalisch-Technische Bundesanstalt für die Wellenlängengenauigkeit).
Resource-saving and sustainable: Hellma® calibration standards can be easily reused for years and remain in use for a long time. There is no need for repetitive, time-consuming preparation and production of calibration solutions, thus conserving resources, the environment and budget. A sustainable and environmentally friendly alternative!
30-year warranty: We trust in our quality and you can rely on reliable measurement results! If you recalibrate regularly – at least every two years – in the Hellma Analytics calibration laboratory, you will receive a 30-year manufacturer's warranty on all Hellma® calibration standards.
*) Note: Calibration laboratory accredited by DAkkS according to DIN EN ISO/IEC 17025. The accreditation is only valid for the scope of accreditation listed in the document annex D-K-18752-01-00.
Certifications: NIST SRM 1930, European Pharmacopoeia, USP 857.
Delivery information: The set, along with an empty mount, is supplied in a sturdy carrying case.
Product Family Options
Glass filter set for checking the photometric accuracy
Product Information
- TypeRangePkAvailabilityPrice
- HELL666S002Neutral glass, absorptions: 0,25/0,5/1,0 AbsNeutral glass, absorptions: 0,25/0,5/1,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 SETLog in for availability1 * 1 SET1 180,00 €
- HELL666S300Neutral glass, conforms to NIST SRM 2930, absorptions: 0,04/2,5/3,0 AbsNeutral glass, conforms to NIST SRM 2930, absorptions: 0,04/2,5/3,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nmLog in for availability1 * 1 SET1 180,00 €
- HELL666S006Neutral glass, absorptions: 0,25/0,5/1,0 AbsNeutral glass, absorptions: 0,25/0,5/1,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nmLog in for availability1 * 1 SET1 240,00 €
- HELL666-S200Neutral glass, absorptions: 0,25/1,0/2,0 AbsNeutral glass, absorptions: 0,25/1,0/2,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nmLog in for availability1 * 1 SET1 180,00 €
- HELL666S004Neutral glass, conforms to NIST SRM 1930, absorptions: 0,3/1,5/2,0 AbsNeutral glass, conforms to NIST SRM 1930, absorptions: 0,3/1,5/2,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nm1 SETLog in for availability1 * 1 SET1 240,00 €
Glass filter to check the wavelength accuracy
Product Information
- TypeRangePkAvailabilityPrice
- 634-9693Holmium oxide glassHolmium oxide glassStandard wavelengths: 279, 361, 453, 536, 638 nmLog in for availability1 * 1 items418,00 €
- HELL666F7W-323Didymium glassDidymium glassStandard wavelengths: 329, 472, 512, 681, 875 nmLog in for availability1 * 1 items446,00 €
Glass filter to check the photometric accuracy
Product Information
- TypeRangePkAvailabilityPrice
- 634-9694Neutral glass, absorptions: 0,25 AbsNeutral glass, absorptions: 0,25 AbsNG 11Standard wavelengths: 440, 465, 546.1, 590, 635 nm1Log in for availability1 * 1 items418,00 €
- 634-9696Neutral glass, absorptions: 1,0 AbsNeutral glass, absorptions: 1,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nmLog in for availability1 * 1 items418,00 €
- HELL666F202-36Neutral glass, absorptions: 1,5 AbsNeutral glass, absorptions: 1,5 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nmLog in for availability1 * 1 items418,00 €
- HELL666F203-36Neutral glass, absorptions: 2,0 AbsNeutral glass, absorptions: 2,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nmLog in for availability1 * 1 items418,00 €
- HELL666F201-39Neutral glass, absorptions: 0,3 AbsNeutral glass, absorptions: 0,3 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nmLog in for availability1 * 1 items418,00 €
- HELL666F390-25Optical glass, absorptions: 0,04 AbsOptical glass, absorptions: 0,04 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nmLog in for availability1 * 1 items418,00 €
- HELL666F301-361Neutral glass, absorptions: 2,5 AbsNeutral glass, absorptions: 2,5 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nmLog in for availability1 * 1 items418,00 €
- HELL666F303-361Neutral glass, absorptions: 3,0 AbsNeutral glass, absorptions: 3,0 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nmLog in for availability1 * 1 items418,00 €
- HELL666F204-37Neutral glass, absorptions: 0,7 AbsNeutral glass, absorptions: 0,7 AbsStandard wavelengths: 440, 465, 546.1, 590, 635 nmLog in for availability1 * 1 items418,00 €
- 634-9695Neutral glass, absorptions: 0,5 AbsNeutral glass, absorptions: 0,5 AbsNG 5Standard wavelengths: 440, 465, 546.1, 590, 635 nm1Log in for availability1 * 1 items418,00 €
Calibration plate for checking the wavelength (W) and photometric (A) accuracy
Product Information
- TypeRangePkAvailabilityPrice
- HELL666R113Neutral glass and reference, Column 1+2: empty - reference; Column 3+4: ND with 0.5 Abs; Column 5+6: ND with 1.0 Abs; Column 7+8: ND with 1.5 Abs; Column 9+10: ND with 2.0 Abs; Column 11+12: Holmium glassNeutral glass and reference, Column 1+2: empty - reference; Column 3+4: ND with 0.5 Abs; Column 5+6: ND with 1.0 Abs; Column 7+8: ND with 1.5 Abs; Column 9+10: ND with 2.0 Abs; Column 11+12: Holmium glassStandard wavelengths: A: 405, 450, 490, 650 mm W: 279, 361, 453, 536, 638 nmLog in for availability1 * 1 items2 800,00 €
Blank frame
Product Information
- TypeRangePkAvailabilityPrice
Calibration plate for checking the photometric accuracy
Product Information
- TypeRangePkAvailabilityPrice
- 634-0999Neutral glass and reference, Column 1+2: empty - reference; Column 3+4: ND with 0.25 Abs; Column 5+6: ND with 0.5 Abs; Column 7+8: ND with 1.0 Abs; Column +10: ND with 1.5 Abs; Column 11+12: ND with 2.5 AbsNeutral glass and reference, Column 1+2: empty - reference; Column 3+4: ND with 0.25 Abs; Column 5+6: ND with 0.5 Abs; Column 7+8: ND with 1.0 Abs; Column +10: ND with 1.5 Abs; Column 11+12: ND with 2.5 Abs666.013Standard wavelengths: 405, 450, 490, 650 nm1Log in for availability1 * 1 items2 480,00 €
Glass filter set for checking the wavelength (W) and photometric (A) accuracy
Product Information
- TypeRangePkAvailabilityPrice
- 634-9691Holmium- and neutral glass, absorptions: 0,25 /0,5/1,0 AbsHolmium- and neutral glass, absorptions: 0,25 /0,5/1,0 AbsStandard wavelengths: A: 440; 465; 546,1; 590; 635 nm W: 279; 361; 453; 536; 638 nm1 SETLog in for availability1 * 1 SET1 550,00 €
- HELL666S005Holmium- and neutral glass, absorptions: 0,5/1,0 AbsHolmium- and neutral glass, absorptions: 0,5/1,0 AbsStandard wavelengths: A: 440; 465; 546,1; 590; 635 nm, W: 279; 361; 453; 536; 638 nm1 SETLog in for availability1 * 1 SET1 240,00 €
Accessories
Product Information
- Catalog #AvailabilityPrice
- Pelicase with inlay for 5 filters
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".
Otherwise, you will receive generic recommendations.