Capillary columns, PLOT
About this item
Aluminum oxide PLOT columns offer high selectivity for separating ppm levels of C1 to C5 hydrocarbons in a main stream of C1 to C5 hydrocarbons.
- High analytical capacity improves efficiency
- No need for sub-ambient cooling simplifies operation
- Choice of two polarities for a broad range of applications
These columns analyze more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. When compared to liquid stationary phases, the CP-Al₂O₃ PLOT column offers increased selectivity and allows all C1 to C5 hydrocarbon isomers to be separated.
Aluminium oxide PLOT columns are deactivated using very small salt crystals, providing a reproducible and stable deactivation up to 200 °C. Depending on the type of deactivation salt, the CP-Al₂O₃ PLOT column will show a particular selectivity. The KCl salt results in a relatively apolar Al₂O₃ surface, while Na₂SO₄ deactivation provides a polar surface. Unsaturated compounds such as ethylene and acetylene (ethyne) are retained longer.
10 Options Available Below
Product Details & Documents
Aluminum oxide PLOT columns offer high selectivity for separating ppm levels of C1 to C5 hydrocarbons in a main stream of C1 to C5 hydrocarbons.
- High analytical capacity improves efficiency
- No need for sub-ambient cooling simplifies operation
- Choice of two polarities for a broad range of applications
These columns analyze more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. When compared to liquid stationary phases, the CP-Al₂O₃ PLOT column offers increased selectivity and allows all C1 to C5 hydrocarbon isomers to be separated.
Aluminium oxide PLOT columns are deactivated using very small salt crystals, providing a reproducible and stable deactivation up to 200 °C. Depending on the type of deactivation salt, the CP-Al₂O₃ PLOT column will show a particular selectivity. The KCl salt results in a relatively apolar Al₂O₃ surface, while Na₂SO₄ deactivation provides a polar surface. Unsaturated compounds such as ethylene and acetylene (ethyne) are retained longer.
Product Family Options
CP-Aluminium oxide/Sodium sulfate UltiMetal
Product Information
- Column FormatFilm thicknessØ int.LengthAvailabilityPrice
- VARICP6968Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary10,00 µm0,53 mm50 mLog in for availability1 * 1 items2 107,38 €
CP-Aluminium oxide/Potassium chloride
Product Information
- Column FormatFilm thicknessØ int.LengthAvailabilityPrice
- VARICP7576Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary4,00 µm0,25 mm25 mLog in for availability1 * 1 items916,61 €
- VARICP7577Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary4,00 µm0,25 mm50 mLog in for availability1 * 1 items1 575,42 €
- VARICP7511Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary5,00 µm0,32 mm10 mLog in for availability1 * 1 items554,47 €
- VARICP7515I5Temperature limits -100 to 200/200 °C, 5 in cageTemperature limits -100 to 200/200 °C, 5 in cageCapillary5,00 µm0,32 mm25 mLog in for availability1 * 1 items1 913,01 €
- VARICP7515Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary5,00 µm0,32 mm50 mLog in for availability1 * 1 items1 708,41 €
- VARICP7519Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary5,00 µm0,32 mm50 mLog in for availability1 * 1 items986,17 €
- VARICP7517Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary10,00 µm0,53 mm25 mLog in for availability1 * 1 items916,61 €
- VARICP7518Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary10,00 µm0,53 mm50 mLog in for availability1 * 1 items1 759,56 €
CP-Aluminium oxide/Potassium chloride UltiMetal
Product Information
- Column FormatFilm thicknessØ int.LengthAvailabilityPrice
- VARICP6918Temperature limits -100 to 200/200 °C, 7 in cageTemperature limits -100 to 200/200 °C, 7 in cageCapillary10,00 µm0,53 mm50 mLog in for availability1 * 1 items2 107,38 €
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".
Otherwise, you will receive generic recommendations.



