33325 Results for: "Self-Tightening Column Nuts for GC"
Capillary column nuts, finger-tight
Supplier: Restek
These finger-tight capillary column nuts made from high-quality stainless steel are an alternative to conventional column nuts. These fittings work best with graphite type ferrules and help prevent over tightening, which can cause graphite material to exude into the inlet.
Expand 2 Items
Fingertight capillary column nuts
Supplier: Restek
These fingertight capillary column nuts rapidly tighten without wrenches and can be used with 0,25, 0,32, or 0,53 mm ID columns.
Expand 2 Items
GC capillary column connectors
Supplier: Trajan Scientific and Medical
Nut, 1/8" hole, stainless steel, Stainless steel
Expand 36 Items
Graphite GC Ferrules
Supplier: Trajan Scientific and Medical
Graphite ferrules are commonly used in GC systems on the inlet and detector ends because they don’t stick to the column, and can be removed and reinserted easily. They should not be used with GC/MS instruments because of permeability to air.
Expand 46 Items
Wrenches, Upchurch Scientific®
Supplier: UPCHURCH SCIENTIFIC
These standard size wrenches can be used to tighten most nuts into unions.
Expand 3 Items
Extender tools
Supplier: UPCHURCH SCIENTIFIC
These tools made from aluminium or Delrin® can be used to tighten most knurled nuts in hard to reach places. For precise tightening, the extender tools listed with ¼" hex drives are designed to adapt to any torque wrench with a female ¼" socket.
Expand 9 Items
Pressure-relief valve with manual ventilation, BOLA
Supplier: Bohlender
Valve made from PPS with flow body made from PTFE. Can be used as a pressure relief valve with adjustable control of pressure or as a valve to prevent a fall in pressure during the filling process. Flow body with 2 GL 18 threaded connectors and valve with toggle for manual venting by tightening, set screw and lock nut to adjust and fix the application pressure in the range from 0,1 to 10 bar (factory setting 1,5 bar).
Expand 1 Items
GC ferrules, SilTite™ FingerTite
Supplier: Trajan Scientific and Medical
Designed to be installed only with the force of your fingers delivering an easy, leak-free installation for capillary columns without the use of any tools. Developed with the unique, leak- and air-free properties of SilTite™ ferrules, which results in superior air tightness to reduce background noise in sensitive MS applications.
Expand 22 Items
Flangeless fingertight nuts
Supplier: VICI JOUR RESEARCH
PEEK flangeless nuts in combination with the inverted ferrule do not require flanging tools. A hand tightening procedure makes leak free seals. The inert ETFE ferrule is the only part, besides the tubing, which is in contact with the fluid, the nut is never in contact with the fluid stream.
Expand 2 Items
Nuts and ferrules for flangeless connections
Supplier: VICI JOUR RESEARCH
Polyacetal flangeless nuts in combination with the inverted ferrule do not require flanging tools. A hand tightening procedure makes leak free seals. The inert ETFE ferrule is the only part, besides the tubing, which is in contact with the fluid, the nut is never in contact with the fluid stream.
Expand 16 Items
Consumables for Shimadzu autosamplers
Supplier: Trajan Scientific and Medical
Autosampler syringes for AOC14, AOC17 and AOC20.
Expand 72 Items
CrossLab supplies for GC systems: for Thermo Scientific
Supplier: Agilent
CrossLab, Column nut, Brass
Expand 88 Items
Capillary column nuts for Agilent GCs
Supplier: Restek
These nuts are designed for Agilent 5890/6850/6890/7890 GCs. Nuts for use with standard ¹/₁₆" type ferrules are designed to fit a wider variety of ¹/₁₆" ferrules.
Expand 4 Items
Consumables for PerkinElmer autosamplers
Supplier: Trajan Scientific and Medical
Autosampler syringes for PerkinElmer AutoSystem.
Expand 32 Items
Interface systems, for GC capillary columns, SWAP-IT
Supplier: Thermo Fisher Scientific
Nut, transfer line
Expand 7 Items
CrossLab supplies for GC systems: for Shimadzu
Supplier: Agilent
CrossLab, Column nut, slotted, 6-sided
Expand 45 Items
CrossLab supplies for GC systems: for PerkinElmer
Supplier: Agilent
CrossLab, Column nut, 1/16"
Expand 42 Items
GC capillary column connectors, SilTite
Supplier: Thermo Fisher Scientific
For use with GC capillary columns and fused silica capillary columns.
Expand 4 Items
Capillary column nuts for Bruker/Varian GCs
Supplier: Restek
These capillary nuts are made from brass or stainless steel.
Expand 2 Items
CrossLab supplies for GC systems: for Bruker, Varian
Supplier: Agilent
CrossLab, Column nut, for injector 1093, Stainless steel
Expand 70 Items
Accessories for GPC columns
Supplier: VARIAN
Column connecting nuts, 1/16 in. tube
Expand 21 Items
Accessories for Clarus® 500 GC
Supplier: PerkinElmer
Replacement column nut, 1/16", connects capillary column to adapter
Expand 1 Items
ValvTool
Supplier: VICI JOUR RESEARCH
For opening and tightening ¹/₄'' nuts.
Expand 1 Items
GC capillary column connectors, Swagelok®
Supplier: PerkinElmer
Connector nuts, plugs and unions for GC instrumentation.
Expand 26 Items
Gas Chromatography 3-Port SilFlow Device
Supplier: Thermo Fisher Scientific
This SilFlow 3-port device allows column switching in GC-MS without the need to vent.
Expand 7 Items
Accessories for HPLC columns
Supplier: MACHEREY-NAGEL
Accessories for stainless steel columns, PEEK fittings and capillaries.
Expand 21 Items
Accessories for ChromCart® cartridge system
Supplier: MACHEREY-NAGEL
CC connecting kit, with 2 nuts of end fittings, two sleeves and two guide rings
Expand 2 Items
Direct injection liner adapter
Supplier: Restek
This direct injection liner adapter uses standard 1,59 mm capillary nut and ferrules. Can be used with Agilent or Restek direct injection glass inserts or Restek direct injection uniliner liners for an Agilent 5890 packed column GC.
Expand 1 Items
Flame ionisation detector (FID) supplies
Supplier: Agilent
Before ordering parts for FID maintenance, determine which type of FID is installed on your GC. The FID is available in two versions: Dedicated, capillary optimized: for capillary columns only. Adaptable: for packed or capillary columns.
Expand 29 Items
Vu-tight installation fittings kit
Supplier: Restek
This kit includes a ¹/₄" stainless steel nut and graphite ferrule for attaching the liner to the GC inlet and a ¹/₄ to ¹/₁₆" stainless steel reducer, plus a ¹/₄" and 0,5 mm ID graphite ferrule for attaching the column to the liner.