You searched for: Chromatography Standards
Frequently used for calibration, the chromatography standards have a known concentration to test separating equipment for performance faults. Analytical equipment error would impact the dependability of retention time, purity, molecular weight, and compound identification conclusions. Improving data quality, the substances allow personnel to plot analyte signal ratios and obtain concentrations from a calibration curve. Chromatography standards verify instruments are suitable for intended ion exchange, gel filtration, and hydrophobic interaction procedures.
Calibration reference materials for autosamplers, Diamond™ DSC
Supplier: PerkinElmer
DSC Standard, Reference material, Perkalloy, Diamond™
Expand 8 Items
Standards for ion chromatograpghy
Supplier: CPACHEM
Standard for Liqid Chromatography, Monoethanolamine 1000 mg/l in water
Expand 7 Items
Standards for liquid chromatography
Supplier: Agilent
Standard for Liqid Chromatography, OQ/PV sample for dissolution test, 150 mg/l, caffeine in water, 500 ml
Expand 2 Items
LC OQ standards kit
Supplier: Restek
Standard for Liqid Chromatography, LC OQ standards kit (acetone)
Expand 1 Items
LC OQ standards kit
Supplier: Restek
Standard for Liqid Chromatography, LC OQ standards kit
Expand 1 Items
LC OQ wavelength accuracy standard
Supplier: Restek
Erbium perchlorate, 14017-55-1
Expand 1 Items
Standards and test mixes for liquid chromatography
Supplier: Restek
Linear detector responses to concentration variations are an important part of operation qualification (OQ) for LC instruments. Kit of five aqueous solutions of caffeine can be used to generate simple plots of UV response versus concentration.
Expand 6 Items
Size exclusion chromatography protein standards, AdvanceBio SEC
Supplier: Agilent
Size Exclusion Standard, AdvanceBio SEC 300Å Protein Standard, lyophilized, 1.5 mL
Expand 2 Items
GC Qualitative standards
Supplier: Agilent
Standard for GC, PolyWax 655, 1 g, neat
Expand 14 Items
Standards for gas chromatography, OQ/PV headspace sample standard
Supplier: Agilent
OQ/PV headspace sample standard contains 0,2 to 0,3% t-butyl disulphide, 1,2-dichlorobenzene, and nitrobenzene in ethanol.
Expand 1 Items
Standards for LC performance, test mix, CRM
Supplier: Restek
Highly effective for characterising LC column parameters and tested against the NIST 870 standard.
Expand 1 Items
FID performance evaluation standard
Supplier: Restek
FID performance evaluation standard contains three components such as (C14) n-Tetradecane (629-59-4), (C15) n-Pentadecane (629-62-9) and (C16) n-Hexadecane (544-76-3).
Expand 1 Items
Test standards for agilent J&W GC column
Supplier: Agilent
GC column test standards contains components that test the column for resolution characteristics, efficiency and inertness.
Expand 8 Items
SEC standards, AdvanceBio
Supplier: Agilent
AdvanceBio SEC Protein Standards are uniquely designed for AdvanceBio SEC columns. The standards are manufactured from a select group of proteins and peptides optimized to deliver accurate, precise quantitation for mAb aggregation and protein analysis.
Expand 2 Items
GC/MS analyser kit standards
Supplier: Agilent
Standard for GC-MS, Butanetriol internal standard #1 for biodiesel
Expand 23 Items
Pre-prepared polystyrene kits, EasiCal™
Supplier: VARIAN
The EasiCal system for organic solvents consists of two different combs, each with ten detachable spatulas supporting a mixture of five polymer standards with MWs selected to provide equidistant calibration points for greater accuracy.
Expand 4 Items
Calibration mixture, Connecticut ETPH
Supplier: Restek
Certified reference materials (CRMs) manufactured and QC-tested in ISO-accredited labs.
Expand 1 Items
Carbohydrate LC performance check mix (5 components)
Supplier: Restek
This carbohydrate LC performance check mix consist of five components which performance qualification (PQ) determines the precision of the LC system.
Expand 1 Items
QuEChERS quality control standards for GC-MS analysis
Supplier: Restek
Pesticide analysis is fast and simple using QuEChERS methods. Use these cost-effective QuEChERS standards for even greaterlab efficiency. Standards are compatible with all major methods, including mini-multiresidue, AOAC, and European procedures.
Expand 2 Items
Pre-weighted calibration kits, EasiVial™
Supplier: VARIAN
The quickest and most convenient method to deliver an accurate 12 point column calibration for organic and aqueous GPC/SEC column calibration.
Expand 18 Items
NPI-1000 column test mix (8 components)
Supplier: Restek
The mix consists of (C9:0) methyl nonanoate, (C13) n-tridecane, (C15) n-pentadecane, acenaphthylene, 4-chlorophenol, 1,6-hexanediol, 4-propylaniline and 1-undecanol.
Expand 1 Items
Polystyrene standards, GPC/SEC columns calibration
Supplier: VARIAN
Polystyrene standards for many organic solvents either for conventional GPC column calibration or for calibrating light scattering and viscosity detectors that provide equidistant calibration points for greater accuracy.
Expand 67 Items
Polymethylmethacrylate standards, GPC/SEC columns calibration
Supplier: VARIAN
Polymethylmethacrylate (PMMA) standards are extremely versatile as they can be used for organic GPC with a wide range of medium polarity eluents, such as tetrahydrofuran, toluene, methyl ethyl ketone and ethyl acetate.
Expand 43 Items
Polyethylene glycol/oxide standards
Supplier: VARIAN
These hydrophilic polymers are suitable for both aqueous SEC and organic GPC using the majority of polar organic solvents. The two types are chemically similar that can be used together across a wider molecular weight range with aqueous and organic polymers.
Expand 58 Items
XERT-500 column test mix (8 components)
Supplier: Restek
This contains (C9:0 FAME) methyl nonanoate, (C13) n-tridecane, (C15) n-pentadecane, acenaphthylene, 4-chlorophenol, n-decylamine, 1,6-hexanediol and 1-undecanol (112-42-5).
Expand 1 Items
Amine column test mix (GC) (8 components)
Supplier: Restek
The amine column test mix consists of (C10) decane (0,60 mg/ml), (C12) dodecane (0.60 mg/ml, 1,2-butanediol (0.60 mg/ml), diethanolamine (DEA) (1.20 mg/ml), diethylenetriamine (1.20 mg/ml), 2,6-dimethylaniline (0.60 mg/ml), 2-nonanol (0.60 mg/ml), pyridine(0.60 mg/ml).
Expand 1 Items
Test mix for NPI-350 column (8 components)
Supplier: Restek
This test mix for NPI-350 column contains: (C9:0 FAME) Methyl nonanoate (1731-84-6); (C13) n-Tridecane (629-50-5); (C15) n-Pentadecane (629-62-9); Acenaphthylene (208-96-8); 4-Chlorophenol (106-48-9); 1,6-Hexanediol (629-11-8); 4-Propylaniline (2696-84-6); 1-Undecanol (112-42-5).
Expand 1 Items
Chiral column test mix (9 components)
Supplier: Restek
The mix consists of (C10:0) Methyl decanoate (210 μg/ml), (C11:0) methyl undecanoate (210 μg/ml), (C12) n-dodecane 150 μg/ml, (C12:0) methyl dodecanoate (210 μg/ml), 2,3-butanediol (+/-) (500 μg/ml), 1-heptanol (180 μg/ml), 3-methylphenol (m-cresol) (160 μg/ml), 1-phenylethanol (+/-) (500 μg/ml) and α-pinene (+/-) (500 μg/ml).
Expand 1 Items
Positive electrophoretic mobility standard, NIST-1980
Supplier: LGC Standards PROMOCHEM
This Standard Reference Material (SRM) is intended for use in the evaluation of equipment, and the validation of methodology used to measure electrophoretic mobility.