You searched for: Rotors
Complete any centrifuge or microcentrifuge sample processing equipment with the appropriate powerful rotor. Both swinging bucket and fixed-angle models securely hold samples at a constant and controlled angle and are flexible with inserted tubes or plates capacity. Ruggedly built to last despite every day usage, rotors are capable of different maximum speeds. Optional bucket covers maximize sealed conditions and minimize leakage or contamination. Autoclavable rotors are manufactured for specific centrifuge compatibility.
Rotor package, Avanti JCF-Z
Supplier: Beckman Coulter
Particles sediment out of the flowing stream, which then emerges from the rotor as a particle-depleted effluent. This process continues until the particle containing capacity of the rotor is reached, or until the starting material (sample) is completely processed. Thus the amount of sample that can be processed in one run is determined by the sample’s volume and concentration of particles.
Expand 2 Items
Electron microscopy rotor, EM-90, Optima
Supplier: Beckman Coulter
Optima™, EM-90 electron microscopy rotor 600 µl, 90000 rpm, 118000 ×g. Major applications: Sedimenting particles onto filter membranes, glass cover slides, and micropscope grids. For use in Airfuge; Air driven micro-ultracentrifuges, For: Ultracentrifugation
Expand 1 Items
Fixed-angle rotor package/assembly, TLA-100
Supplier: Beckman Coulter
Major applications: Pelleting of subcellular fractions; proteins; RNA.
Expand 2 Items

Avantor in the heart of every lab!
Discover our special offers on laboratory products from Consumables to Equipment used in every lab!
Rotors for Sorvall™ BIOS 16 centrifuges
Supplier: Thermo Fisher Scientific
Swinging bucket rotor, 6×1000 ml, 5400 min-1, 8500 ×g, incl. round buckets and 1000 ml bottles, For: Sorvall™ BIOS 16
Expand 4 Items
Fixed-angle titanium rotor, Type 70 Ti, Optima
Supplier: Beckman Coulter
Optima™, Type 70 Ti fixed angle titanium rotor. For use in instruments classified: HRS; Major applications: Differential centrifugation of subcellular particles, For: Ultracentrifugation
Expand 1 Items
Rotor assembly, Avanti JS-7.5
Supplier: Beckman Coulter
JS-7.5 swinging bucket (high performance) rotor for 7500 rpm operation. Includes 4×250 ml buckets. Multitube carriers available separately. Tubes and bottles not included
Expand 1 Items
Fixed-angle aluminum rotor assembly, Type 19, Optima
Supplier: Beckman Coulter
Optima™, Type 19 fixed angle aluminum rotor assembly. Major applications: Differential centrifugation of large volumes of viruses and large subcellular particles, For: Ultracentrifugation
Expand 1 Items
Fixed-angle aluminium rotor, Avanti JA-18.1
Supplier: Beckman Coulter
JA-14.50 fixed angle (high performance) aluminium rotor, with BioSafe dual-locking lid, 16×50 ml conical, 14000 rpm, 35000×g for use in Avanti J Series centrifuges
Expand 2 Items
Fixed-angle rotor, A-100/18, Optima
Supplier: Beckman Coulter
Optima™, A-100/18 fixed angle rotor, 6×175 µl, 95000 rpm, 149000 ×g. Major applications: Fast pelleting of very small samples. For use in Airfuge; Air driven micro ultracentrifuges, For: Ultracentrifugation
Expand 1 Items
Rotors and accessories for RC3BP Plus low-speed centrifuge
Supplier: SORVALL
Swinging bucket rotor H-6000A, for 6×1000 ml tubes (98×175 mm), 5000 min-1, 7277 ×g, including six buckets, For: RC3 series
Expand 2 Items
Fixed-angle aluminium rotor, Avanti JA-25.15
Supplier: Beckman Coulter
JA-25.15 fixed angle (high performance) aluminium rotor with single locked lid, 24×15 ml, 25000 rpm, 74200×g, for Avanti J Series centrifuges (except Avanti J-E) and J2 Series centrifuges
Expand 1 Items
Rotor assembly, Avanti JS-4.0
Supplier: Beckman Coulter
Unshielded, four-place rotor with aluminium rotor yoke and removable aluminium swinging buckets. Buckets are interchangeable with microplate carriers for spinning microtitre plates and minitube racks. Holds up to four litres, four blood bags or four microtitre plate carriers. Accepts all multi-disc adapters except 339119. Note: requires tie-down kit (367045) for use with Avanti J-26 XP Series centrifuges.
Expand 1 Items
Fixed-angle rotor with biosafe lid, Avanti JA-25.15
Supplier: Beckman Coulter
JA-25.15 fixed angle (high performance) aluminium rotor with Biosafety lid, 24×15 ml, 25000 rpm, 74200×g for Avanti J Series centrifuges (except Avanti J-E) and J2 Series
Expand 1 Items
Fixed-angle rotor, A-110, Optima
Supplier: Beckman Coulter
Optima™, A-110 fixed angle rotor, 6×180 µl, 110000 rpm, 199000 ×g. Major applications: Fast pelleting of very small samples. For use in Airfuge; Air driven micro ultracentrifuge, For: Ultracentrifugation
Expand 1 Items
Rotor package, Avanti JA-30.50
Supplier: Beckman Coulter
JA-30.50 Ti fixed angle (high performance) titanium rotor, with Biosafety lid, 8×50 ml, 30000 rpm, 108860 ×g. For use in Avanti J Series centrifuges (except Avanti J-E and J-HC) and J2 Series centrifuges
Expand 2 Items
Rotor package, Avanti JLA 8.1000
Supplier: Beckman Coulter
J-LITE JLA-8.1000 fixed angle (high performance) aluminium rotor package, 6×1000 ml, 8000 rpm, 15970 ×g. Package includes JLA-8.1000 Rotor (969328, 969329); lid with removable canisters (363563, 363686) cap/closure with PC auto vent plug assembly (363680, A98812), labware kit includes: Bottle rack, spatula, bottle grip and wrench (392574). For use in Avanti J-26 XP Series and Avanti J-26S Series centrifuges
Expand 1 Items
Swinging-bucket rotor, MLS-50, Optima
Supplier: Beckman Coulter
Optima™, MLS-50 swinging bucket rotor, 4×5 ml, 50000 rpm. Major applications: Rate-zonal separation of subcellular organelles, pelleting and isopycnic separations of RNA. For use in Optima MAX-XP benchtop ultracentrifuge, For: Ultracentrifugation
Expand 1 Items
Rotor assembly, Avanti JLA-10.500
Supplier: Beckman Coulter
J-LITE JLA-10.500 fixed angle (high performance) aluminium rotor, 6×500 ml, 10000 rpm, 18600 ×g. Includes 6 Biosafety liquid canisters with secondary liquid closures. For use in Avanti J Series and J2 Series centrifuges
Expand 1 Items
Rotor assembly with labware kit, Avanti JS-5
Supplier: Beckman Coulter
JS-5.0 swinging bucket (high performance) rotor package. For use in Avanti J-HC centrifuges. Package includes rotor body and lid with four removable buckets and labware kit: Red ccover gaskets, for use without liners (369257 set of 4); green cover gaskets with liners (369261 set of 4); air vent filters (368148 set of 60); spatulas (367891 set of 2), 2× cup racks 4 J-wide cups and cup covers with plugs
Expand 1 Items
Rotor package, MLN-80 NVT, Optima
Supplier: Beckman Coulter
Optima™, MLN-80 NVT rotor package, 80000 rpm, 389000 ×g, 8×8 ml. Major applications: Rapid contamination-free isopycnic isolation of plasmid DNA. For use in Optima MAX-XP benchtop ultracentrifuges and Optima MAX ultracentrifuges, For: Ultracentrifugation
Expand 1 Items
Fixed-angle titanium rotor package, MLA-150
Supplier: Beckman Coulter
Major applications: Separation of subcellular particles (pelleting, rate-zonal gradient), viruses (pelleting, rate-zonal gradient), protein purification/isolation (pelleting, rate-zonal gradient), DNA (pelleting, CsCl isopycnic), RNA (CsCl pelleting, density gradient), lipoproteins (differential flotation or gradient).
Expand 1 Items
Rotor assembly, Avanti JS-24.38
Supplier: Beckman Coulter
JS-24.38 swinging bucket (high performance) aluminium rotor, titanium buckets. For use in Avanti J Series centrifuges (except Avanti J-E). Reaches 24000 rpm in the Avanti J-30I centrifuge only. Not recommended for use in Avanti J-25 Series (max. speed 10,000 rpm), or Avanti J-20XP Series (max. speed 10000 rpm). Incompatible with all J2 Series
Expand 1 Items
Swinging-bucket rotor, SW 41 Ti, Optima
Supplier: Beckman Coulter
Optima™, SW 41 Ti swinging bucket rotor, For: Ultracentrifugation
Expand 1 Items
Fixed-angle aluminium rotor, MLA-50
Supplier: Beckman Coulter
MLA-50 fixed-angle aluminum rotor, major applications: Subcellular isolations
Expand 1 Items
Rotors for cell washer
Supplier: Thermo Scientific
Meets protocol requirements with the flexibility to run 12 or 24 samples and finish washing in as little as 3 minutes with Thermo Scientific™ cell washer rotors.
Expand 2 Items
Fixed-angle titanium rotor, Type 50.4 Ti, Optima
Supplier: Beckman Coulter
Optima™, Type 50.4 Ti fixed angle titanium rotor, For: Ultracentrifugation
Expand 1 Items
Near-vertical rotor, NVT 65.2, Optima
Supplier: Beckman Coulter
Optima™, NVT 65.2 titanium near-vertical rotor assembly, 65000 rpm, 416000 ×g, 16×5,1 ml. Includes: Vise (342705), Torque Wrench (858121), Torx Plug-Wrench Adapter (976959), Spinkote Lubricant (306812) and overspeed disks, 65000 rpm (330338). For use in Optima series ultracentrifuges and/or instruments classified: HRS, For: Ultracentrifugation
Expand 1 Items
HAEMAFlex™ 6/8 Swinging Bucket Rotors
Supplier: Thermo Scientific
Address lab’s regular- to medium-throughput blood processing needs with the Thermo Scientific™ HAEMAFlex™ six swinging bucket rotor with 6×550 ml blood bag capacity or, utilising the same bucket system, upgrade to 8×550 ml bags with the Thermo Scientific™ HAEMAFlex™ eight swinging bucket rotor.
Expand 2 Items
Rotor assembly, Avanti JS24.15
Supplier: Beckman Coulter
JS-24.15 swinging bucket (high performance) aluminium rotor, titanium buckets. For use in Avanti J Series centrifuges (except Avanti J-E and Avanti J-HC). Reaches 24000 rpm in the Avanti J-30I centrifuge only. Not recommended for use in Avanti J-25 Series (max speed 10000 rpm), or Avanti J-26 XP Series (max. speed 10000 rpm). Incompatible with all J2 Series
Expand 1 Items
Fixed-angle titanium rotor package/assembly, TLA-120.1
Supplier: Beckman Coulter
Major applications: Pelleting of subcellularfractions in 5 to 30 minutes; plasmid DNA separation in 3 hours.