Order Entry
Singapore
Orders LinkContactUsLinkComponent
 

"HAMILTON BONADUZ"

 
 
pH buffers, DuraCal

pH buffers, DuraCal

Supplier: HAMILTON BONADUZ

For full information concerning health and safety data please contact Avantor or Hamilton directly.

Expand 6 Items
 
Syringes, Neuros™

Syringes, Neuros™

Supplier: HAMILTON BONADUZ

Developed specifically for the neurosciences, these syringes minimise injection site damage by increasing needle rigidity and delivering a micro volume of liquid to an exact location.

Expand 4 Items
 
Anion exchange HPLC columns, PRP-X100

Anion exchange HPLC columns, PRP-X100

Supplier: HAMILTON BONADUZ

The PRP-X100 is a polymeric column packing for separation of inorganic and organic anions from 10 to 500 ppm. These columns can be used to separate ions at concentrations from 1 to 1000 ppm without suppression or elaborate preconcentration techniques. The highly inert polymeric support resists chemical attack from organic solvents and aqueous buffers (0 - 100% aqueous or organic; pH 1 to 13), effectively lengthening column life.

Expand 2 Items
 
Needle cleaning concentrate and wires

Needle cleaning concentrate and wires

Supplier: HAMILTON BONADUZ

To clean syringes it is best to use a solvent known to be effective in solvating. Ideally the solvent would be non-alkaline, non-phosphate, and non-detergent based.

Expand 2 Items
 
Microliter™ 700 series syringes

Microliter™ 700 series syringes

Supplier: HAMILTON BONADUZ

The 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0,5 to 500 µl. The stainless steel plunger is manufactured to fit the glass barrel with a tolerance smaller than 100 millionths of an inch, resulting in unsurpassed syringe life. Each syringe is manufactured to achieve the highest level of accuracy and precision possible.

Expand 17 Items
 
Miniature inert valves, HV series

Miniature inert valves, HV series

Supplier: HAMILTON BONADUZ

HV plug valves provide an economical and flexible method of custom-building a fluid flow control system, from a simple on/off valve to a more complex multi-valve arrangement, using a combination of loop and distribution valves.

Expand 3 Items
 
GC autosampler syringes for Bruker Varian Chrompack

GC autosampler syringes for Bruker Varian Chrompack

Supplier: HAMILTON BONADUZ

These GC syringes are suitable for Bruker Varian Chrompack autosamplers.

Expand 1 Items
 
Modified syringes Microliter™7000 series

Modified syringes Microliter™7000 series

Supplier: HAMILTON BONADUZ

Suitable for applications such as GC, TLC and micro pipetting. Manufactured according to the principle of dead volume by positive pressure. A tungsten piston is introduced into the syringe as far as the tip of the needle. Needle and piston are calibrated against each other and must be changed at the same time in the event of replacement.

Expand 4 Items
 
Microlitre™ syringes for manual HPLC injections on Rheodyne and Valco valves

Microlitre™ syringes for manual HPLC injections on Rheodyne and Valco valves

Supplier: HAMILTON BONADUZ

NR = Rheodyne needle
RNR = Replacement Rheodyne needle

Expand 10 Items
 
600 series Microliter™ syringes

600 series Microliter™ syringes

Supplier: HAMILTON BONADUZ

The 600 series syringes are a half stroke version of the original 700 series syringes. This series of syringes is ideal for dispensing volumes from 0,25 μl up to 5 μl. The 600 series is often used in applications that require one handed operation because of the short stroke length and the reinforced plunger.

Expand 2 Items
 
Compression fittings

Compression fittings

Supplier: HAMILTON BONADUZ

The compression fittings and adaptors are designed to connect Hamilton removable needle (RN) and knurled hub (KH) syringes to glass capillary tubing and PEEK tubing. The connectors can be combined in a variety of different configurations to meet most connection needs.

Expand 3 Items
 
Anion exchange HPLC columns, RCX-30

Anion exchange HPLC columns, RCX-30

Supplier: HAMILTON BONADUZ

RCX-30 carbohydrate analysis columns are designed for the isocratic or gradient separation of carbohydrates. When an isocratic method is used with a conductivity, refractive index, ultraviolet, or pulsed amperometric detector (PAD), mono and disaccharides such as glucose, fructose, sucrose and lactose can be quickly determined.

Expand 1 Items
 
Syringes for thin layer chromatography

Syringes for thin layer chromatography

Supplier: HAMILTON BONADUZ

The needle points of these thin layer chromatography syringes are covered with a PTFE coating which reduces the surface tension between the needle and the liquid making it ideal for reproducible sample spotting.

Expand 2 Items
 
Gastight® 1800 series syringes

Gastight® 1800 series syringes

Supplier: HAMILTON BONADUZ

The 1800 series is the reinforced plunger version of the 1700 series syringe. Attached to the flange of the syringe is a removable blue syringe holder that prevents heat transfer, dispense inaccuracies and plunger blow outs. It also provides support to small volume plungers that are prone to bending during injection.

Expand 1 Items
 
Repeating dispensing system, PB600-1

Repeating dispensing system, PB600-1

Supplier: HAMILTON BONADUZ

The PB600-1 works with Microliter™ or Gastight® syringes from 10 µl to 2,5 ml. Use the repeating dispenser with cemented needles (N), removable needles (RN), Luer tip (LT), or PTFE Luer lock (TLL) syringes.

Expand 1 Items
 
Syringes for HPLC autosamplers, PerkinElmer instruments

Syringes for HPLC autosamplers, PerkinElmer instruments

Supplier: HAMILTON BONADUZ

Gastight syringes for use with gases or liquids. Designed with or without ChemSeal (C) termination.

Expand 2 Items