These bench top meters with pH/ISE, conductivity and Dissolved Oxygen/RDO modules meet the most challenging applications for pH, ion concentration, conductivity, dissolved oxygen and temperature. The meters offer interchangeable measurement modules that allow multiple users to customise four separate channels to meet their specific requirements.
- Colour display with adjustable text sizes; numeric keypad; onscreen measurement stability indicator
- Auto-Read to hold a stable reading; ten password-protected methods per channel
- Audible alarms automatically notify users when a set offset value, high/low limit value, and calibration time interval are reached
- Uniformly mix solutions using up to two meter-controlled stirrer probes that are easy to position and can be quickly rinsed between samples
- Data log collects and date/time stamps up to 2000 measurement sets with optional electrode ID, sample ID and account ID
- Calibration log stores ten most recent calibrations per parameter with viewable graph for multipoint pH and ISE calibrations
- Meter facilitates data transfers to a computer via USB or RS232 connections
IP 54-rated housing resists dust and splashes and can be wall-mounted if table space is limited.
When used in conjunction with the Orion Navigator Pro software, the Orion Versa Star Pro meter is designed to create electronic data records and audit trails with password-protection, which can be used to assist with 21 CFR Part 11 requirements when paired with each laboratory’s proper IT protocols, SOPs and training records.*Orion Navigator Pro software offers multi-level system access for an administrator and up to 10 users. The system administrator can customize each user’s access level from full system access to basic data collection only. The Navigator Pro software controls all meter functions including meter settings, calibration, measurement, and reporting to help ensure data integrity and provide a complete audit trail.
Features and benefits
- Generates electronic records and signatures
- Creates audit trail report for electronic records
- Limits access to authorized individuals
- Password protection with system administrator and up to 10 users
- Full computer control of meter functions including setup, calibration and measurement
- Paperless record keeping system
Kits additionally include: 8157BNUMD ROSS Ultra Triode epoxy-body pH/ATC electrode, 013005MD Orion DuraProbe 4-cell (K=0,475) conductivity sensor, 083005MD Orion polarographic dissolved oxygen sensor, 096019 Orion Star stirrer probe, 810199 ROSS pH buffer and solution kit, 011007 Orion 1413 µS conductivity standard, 080513 DO maintenance kit, BOD adapter/funnel/stirrer.
- Catalog No:
- ORIOVSTAR90
- ORIOVSTAR91
- ORIOVSTAR92
- ORIOVSTAR93
- Model:
- Orion™ Versa Star Pro™
- Orion™ Versa Star Pro™
- Orion™ Versa Star Pro™
- Orion™ Versa Star Pro™
- pH range:
- −2000...+20000
- −2000...+20000
- −2000...+20000
- −2000...+20000
- pH resolution:
- 0,1/0,01/0,001
- 0,1/0,01/0,001
- 0,1/0,01/0,001
- 0,1/0,01/0,001
- pH accuracy:
- ±0,002
- ±0,002
- ±0,002
- ±0,002
- pH calibration:
- Up to 6 points
- Up to 6 points
- Up to 6 points
- Up to 6 points
- mV range:
- ±2000,0
- ±2000,0
- ±2000,0
- ±2000,0
- mV resolution:
- 0,1
- 0,1
- 0,1
- 0,1
- mV accuracy:
- ±0,2 or 0,05% of reading (whichever is greater)
- ±0,2 or 0,05% of reading (whichever is greater)
- ±0,2 or 0,05% of reading (whichever is greater)
- ±0,2 or 0,05% of reading (whichever is greater)
- mV calibration:
- 1 point
- 1 point
- 1 point
- 1 point
- ISE range:
- 0,0001 - 19990 ppm
- 0,0001 - 19990 ppm
- 0,0001 - 19990 ppm
- 0,0001 - 19990 ppm
- ISE resolution:
- 0,0001 minimum, 1 to 4 significant digits (user selectable)
- 0,0001 minimum, 1 to 4 significant digits (user selectable)
- 0,0001 minimum, 1 to 4 significant digits (user selectable)
- 0,0001 minimum, 1 to 4 significant digits (user selectable)
- ISE accuracy:
- ±0,2 mV or ±0,05% of reading (whichever is greater)
- ±0,2 mV or ±0,05% of reading (whichever is greater)
- ±0,2 mV or ±0,05% of reading (whichever is greater)
- ±0,2 mV or ±0,05% of reading (whichever is greater)
- ISE calibration:
- Up to 6 points
- Up to 6 points
- Up to 6 points
- Up to 6 points
- ISE units:
- ppm, Molar, mg/L, %, ppb or none
- ppm, Molar, mg/L, %, ppb or none
- ppm, Molar, mg/L, %, ppb or none
- ppm, Molar, mg/L, %, ppb or none
- Conductivity range:
- 0,001 µS/cm - 3000 mS/cm
- 0,001 µS/cm - 3000 mS/cm
- 0,001 µS/cm - 3000 mS/cm
- 0,001 µS/cm - 3000 mS/cm
- Conductivity resolution:
- 0,001 μS minimum, auto ranging up to 4 significant digits
- 0,001 μS minimum, auto ranging up to 4 significant digits
- 0,001 μS minimum, auto ranging up to 4 significant digits
- 0,001 μS minimum, auto ranging up to 4 significant digits
- Conductivity accuracy:
- 0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
- 0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
- 0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
- 0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
- Conductivity cell constant:
- 0,001 - 199,9 cm⁻¹
- 0,001 - 199,9 cm⁻¹
- 0,001 - 199,9 cm⁻¹
- 0,001 - 199,9 cm⁻¹
- Conductivity calibration:
- Up to 6 points
- Up to 6 points
- Up to 6 points
- Up to 6 points
- Resistivity range:
- 2 Ω/cm - 100,0 MΩ/cm
- 2 Ω/cm - 100,0 MΩ/cm
- 2 Ω/cm - 100,0 MΩ/cm
- 2 Ω/cm - 100,0 MΩ/cm
- Resistivity accuracy:
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- Resistivity resolution:
- 1 Ω/cm/0,1 MΩ/cm
- 1 Ω/cm/0,1 MΩ/cm
- 1 Ω/cm/0,1 MΩ/cm
- 1 Ω/cm/0,1 MΩ/cm
- Salinity range:
- 0,06 - 80,00 psu/0,05 - 42,00 ppt
- 0,06 - 80,00 psu/0,05 - 42,00 ppt
- 0,06 - 80,00 psu/0,05 - 42,00 ppt
- 0,06 - 80,00 psu/0,05 - 42,00 ppt
- Salinity resolution:
- 0,01 psu or 0,01 ppt minimum, auto ranging
- 0,01 psu or 0,01 ppt minimum, auto ranging
- 0,01 psu or 0,01 ppt minimum, auto ranging
- 0,01 psu or 0,01 ppt minimum, auto ranging
- Salinity accuracy:
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- TDS range:
- 0,001 - 200,0 ppm
- 0,001 - 200,0 ppm
- 0,001 - 200,0 ppm
- 0,001 - 200,0 ppm
- TDS resolution:
- 0,001 ppm minimum, auto ranging up to 4 significant digits
- 0,001 ppm minimum, auto ranging up to 4 significant digits
- 0,001 ppm minimum, auto ranging up to 4 significant digits
- 0,001 ppm minimum, auto ranging up to 4 significant digits
- TDS accuracy:
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- TDS conversion factor:
- Linear (0,02 - 9,99)
- Linear (0,02 - 9,99)
- Linear (0,02 - 9,99)
- Linear (0,02 - 9,99)
- DO concentration:
- DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
- DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
- DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
- DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
- DO concentration resolution:
- 0,01/0,1 mg/L
- 0,01/0,1 mg/L
- 0,01/0,1 mg/L
- 0,01/0,1 mg/L
- DO saturation:
- 0,0 - 600,0 %
- 0,0 - 600,0 %
- 0,0 - 600,0 %
- 0,0 - 600,0 %
- DO accuracy:
- DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
±2 % saturation or ±2% of reading whichever is greater - DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
±2 % saturation or ±2% of reading whichever is greater - DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
±2 % saturation or ±2% of reading whichever is greater - DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
±2 % saturation or ±2% of reading whichever is greater
- DO barometric pressure range:
- 400 - 850 mmHg
- 400 - 850 mmHg
- 400 - 850 mmHg
- 400 - 850 mmHg
- Temperature range:
- −5,0...+105,0 °C
- −5,0...+105,0 °C
- −5,0...+105,0 °C
- −5,0...+105,0 °C
- Temperature resolution:
- 0,1 °C
- 0,1 °C
- 0,1 °C
- 0,1 °C
- Temperature accuracy:
- ±0,1 °C
- ±0,1 °C
- ±0,1 °C
- ±0,1 °C
- Temperature calibration:
- 1 point offset
- 1 point offset
- 1 point offset
- 1 point offset
- Temperature compensation:
- Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
- Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
- Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
- Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
- Display:
- Colour graphic LCD with backlight
- Colour graphic LCD with backlight
- Colour graphic LCD with backlight
- Colour graphic LCD with backlight
- Power supply:
- Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
- Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
- Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
- Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
- Compliance:
- IP 54
- IP 54
- IP 54
- IP 54
- Operating temperature range:
- 5...45 °C (ambient)
- 5...45 °C (ambient)
- 5...45 °C (ambient)
- 5...45 °C (ambient)
- Data logging - log function:
- Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
- Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
- Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
- Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
- Data logging capacity:
- 2000 points
- 2000 points
- 2000 points
- 2000 points
- Languages:
- English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
- English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
- English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
- English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
- Connections:
- BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
- BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
- BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
- BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
- Outputs:
- RS232, USB (2)
- RS232, USB (2)
- RS232, USB (2)
- RS232, USB (2)
- No. of channels:
- 4 - customisable with modules
- 4 - customisable with modules
- 4 - customisable with modules
- 4 - customisable with modules
- Calibration:
- pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
- pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
- pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
- pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
- Calibration points:
- 1 point relative mV (RmV) mode, 1 point ORP mode
- 1 point relative mV (RmV) mode, 1 point ORP mode
- 1 point relative mV (RmV) mode, 1 point ORP mode
- 1 point relative mV (RmV) mode, 1 point ORP mode
- W×D×H:
- 280×240×100 mm
- 280×240×100 mm
- 280×240×100 mm
- 280×240×100 mm
- Weight:
- 1,2 kg (modules add 0,2 kg each)
- 1,2 kg (modules add 0,2 kg each)
- 1,2 kg (modules add 0,2 kg each)
- 1,2 kg (modules add 0,2 kg each)