Order Entry
Sweden
Orders LinkContactUsLinkComponent
238 resultat för "Solid Phase Extraction"

"Solid Phase Extraction"

238 Resultat
Sortera efter

Solid phase extraction cartridges, Bond Elut™ PBA

Supplier: VARIAN

PBA is a unique sorbent consisting of a phenylboronic acid covalently linked to a silica gel surface. Covalent processes result in a higher retention to the sorbent surface than other mechanisms, resulting in superior clean-up. The boronate group has a high specificity for cis-diol containing compounds such as catechols, nucleic acids, low molecular weight proteins and carbohydrates.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ PRS

Supplier: VARIAN

Bond Elut™ PRS is a strong cation exchange sorbent that is also relatively high in polarity. With no appreciable degree of hydrophobicity, in non-polar solvents, PRS is capable of polar and hydrogen bonding interactions. Due to the very low pKa of PRS, a high ionic strength eluent must be used, and so the use of PRS is recommended for weaker cationic species such as pyridinium compounds.

Expand 7 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ PSA

Supplier: VARIAN

Bond Elut™ PSA is an alkylated amine sorbent that contains two different amino functionalities, one secondary and one primary. This gives a slightly higher pKa and ionic capacity compared to Bond Elut™ NH₂. The PSA functional group is a very effective bidentate ligand and is therefore an excellent sorbent for chelation applications. PSA has a significantly higher carbon load than most amino functional sorbents and thus is a better choice for polar compounds, which retain too strongly on Bond Elut™ NH₂.

Expand 8 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Diol

Supplier: VARIAN

Bond Elut™ Diol (2OH) resembles unbonded silica in its tendency for strong hydrogen bonding with analytes. 2OH can also be employed in the non-polar mode because the hydrocarbon spacer on its functional group provides enough non-polar character for retention of hydrophobic analytes. Bond Elut™ Diol is a listed SPE device for the DIN 14333-1 method on benzimidazole fungicides.

Expand 6 Items
Loading...
Accessories for empty solid phase extraction columns CHROMABOND®

Accessories for empty solid phase extraction columns CHROMABOND®

Supplier: MACHEREY-NAGEL

CHROMABOND®, Adapters (PP) for PP columns (1, 3 and 6 ml)

Expand 16 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ NH₂

Supplier: VARIAN

Bond Elut™ NH₂ is a weaker anion exchanger than sorbents such as SAX (a quaternary amine sorbent that is always charged) and is therefore a better choice for retention of very strong anions, such as sulfonic acids, which may retain irreversibly on a SAX sorbent. Similar to Diol and SI sorbents, Bond Elut™ NH₂ is excellent for the separation of structural isomers.

Expand 24 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ C8

Supplier: VARIAN

Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.

Expand 23 Items
Loading...
Empty solid phase extraction cartridges with two frits, Bond Elut™

Empty solid phase extraction cartridges with two frits, Bond Elut™

Supplier: VARIAN

Clean PP reservoirs contain two PP frits pre-inserted, an ideal configuration for simple filtration.

Expand 7 Items
Loading...
Solid phase extraction cartridges, Bond Elut™ C18

Solid phase extraction cartridges, Bond Elut™ C18

Supplier: VARIAN

Bond Elut™ C18 is the most hydrophobic, bonded silica sorbent in the Bond Elut™ range. It is the most popular SPE sorbent because of its extremely retentive nature for non-polar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices. When analysing small to intermediate molecules, Bond Elut™ C18 can be used for desalting aqueous matrices prior to ion exchange, as salts pass through the sorbent unretained.

Expand 18 Items
Loading...

Accessories for solid phase extraction cartridges, Bond Elut™ SPEC

Supplier: VARIAN

Bond Elut™, Environmental disk manifold

Expand 3 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ NEXUS and NEXUS WCX

Supplier: VARIAN

Bond Elut™ NEXUS is an ultra-clean polymeric sorbent which has bi-modal porosity and a high surface area. NEXUS offers a nonpolar retention mechanism with no pre-conditioning required. The large particle size makes NEXUS ideal for extractions from highly viscous samples, such as horse urine.

Based on the same base polymer technology, Bond Elut™ NEXUS WCX is a weak cation exchange sorbent that offers extra selectivity for analytes, such as quaternary ammonium drugs and anabolic steroids.

Expand 8 Items
Loading...
Hazardous Waste Filtration System

Hazardous Waste Filtration System

Supplier: Merck

If your waste samples contain non-volatile or semi-volatile substances or metals, use this hazardous waste filtration system for saparation, extratction, and filtration. Developed in collaboration with the US Environmental Protection Agency (EPA), the system is designed specifically for the US EPA Extraction Procedure (EP) Toxicity Test and Toxicity Characteristic Leaching Procedure (TCLP). The device separates solid and liquid phases of waste samples for analysis.

Expand 3 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Plexa PCX

Supplier: VARIAN

Bond Elut™ Plexa PCX uses a polymeric cation exchange resin that combines the outstanding properties of Bond Elut™ Plexa - superior flow characteristics and improved analytical performance - with strong cation exchange functionalities. This mixed-mode SPE sorbent removes neutral and acidic interferences from the matrix, concentrates basic analytes and therefore improves sensitivity in the determination of basic compounds.

Expand 11 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ SCX

Supplier: VARIAN

Bond Elut™ SCX is a strong cation exchanger with a very low pKa. Although the pKa is similar to Bond Elut™ PRS, the presence of the benzene ring in the functional group increases the potential for non-polar interactions. This non-polar characteristic becomes particularly important when conducting ion-exchange from aqueous systems, where selectivity towards compounds exhibiting cationic and non-polar character is seen.

Expand 24 Items
Loading...

Supelco® TraceCERT® Organic Reference Standard, Tebufenpyrad

Supplier: Merck

Profenofos CRM may also be used as given below: Evaluation of 250 pesticide residues extracted by QuEChERS method from 103 processed fruit samples using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS. Gas chromatography-tandem mass spectrometry (GC-MS/MS) based analysis of 213 pesticide residues in soybean after their extraction by QuEChERS procedure. Detection of 252 pesticides extracted from surface water samples by solid-phase extraction (SPE) using liquid chromatography quadrupole-orbitrap high-resolution tandem mass spectrometry. Multi-residue analysis of 160 multiclass pesticides using ethyl acetate (EtAC)/n. hexane mixture for extraction from chamomile thyme and marjoram samples and their analysis by gas chromatography-tandem mass spectrometry (GC-MS/MS). Simultaneous determination of 34 pesticides in various environmental water samples by dispersive liquid-liquid microextraction (DLLME) technique in combination with gas chromatography-mass spectrometry(GC-MS/MS). Quantitation of 40 multi-class insecticides and fungicides in 81 apple samples by using gas- and liquid- chromatography-mass following a QuEChERS-based extraction.

Expand 1 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Sodium Sulphate Drying

Supplier: VARIAN

Bond Elut™ Jr cartridges have top and bottom Luer fittings allowing easy sample processing when used in conjunction with standard SPE cartridges. Bond Elut™ LRC cartridges have a large reservoir above the sorbent bed and are suitable for use on any standard SPE vacuum manifold.

Expand 5 Items
Loading...
Sortera efter
Recommendations

Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".

Otherwise, you will receive generic recommendations.