Order Entry
Sweden
ContactUsLinkComponent
201 resultat för "Solid Phase Extraction"

201 Resultat för: "Solid Phase Extraction"

Sortera efter

SPE plates, 96-well, HyperSep™, Silica

Supplier: Thermo Fisher Scientific

Thermo Scientific™ HyperSep Silica SPE 96-Well Plates and Individual Wells feature a polar sorbent primarily used to retain analytes in non polar matrices, and can effectively separate compounds of very similar structure.

Expand 4 Items
Laddar...

Specialty solid phase extraction cartridges, Bond Elut™ Carbon/NH₂

Supplier: VARIAN

These specialty solid phase extraction cartridges provide higher retention of small organics, including those that are too polar to retain on C18 or polymeric SPE.

Expand 7 Items
Laddar...

SPE plates, 96-well, HyperSep™, Aminopropyl

Supplier: Thermo Fisher Scientific

Thermo Scientific™ HyperSep Aminopropyl SPE 96-Well Plates and Individual Wells feature a polar sorbent that allows both polar and anion exchange interactions. The chemistry offers good retention of drugs, metabolites and structural isomers.

Expand 3 Items
Laddar...

Solid phase extraction disks, Resprep®

Supplier: Restek

These glass fiber disks are embedded with C18 or C8 bonded silica. Deep-pore design reduces clogging and allows faster flow rates. Semivolatile organic compounds can be etracted.

Expand 1 Items
Laddar...

SPE plates, 96-well, HyperSep™, C18

Supplier: Thermo Fisher Scientific

Thermo Scientific HyperSep™ C18 SPE 96-well plates and individual wells feature a highly retentive alkyl-bonded phase for non polar to moderately polar compounds. The hydrophobic reversed phase material is retentive for most nonpolar compounds, and retains most organic analytes from aqueous matrices.

Expand 5 Items
Laddar...

Solid phase extraction cartridges, EnvirElut™

Supplier: VARIAN

EnvirElut™ sorbents are specially designed for the extraction of a wide range of compounds from aqueous matrices. EnvirElut™ PAH and Pesticides are available in standard SPE straight barrel cartridges, which can be used on conventional vacuum manifolds such as the Vac Elut SPS 24.

Expand 6 Items
Laddar...

SPE plates, 96-well, HyperSep™ C8

Supplier: Thermo Fisher Scientific

HyperSep C8 SPE Well Plates and Individual Wells provide excellent performance characteristics for moderately polar analytes. They also offer the potential for polar interactions greater than with C18.

Expand 4 Items
Laddar...

SPE plates, 96-well, HyperSep™ Diol

Supplier: Thermo Fisher Scientific

The sorbent used in Thermo Scientific™ HyperSep™ Diol Plates features short alkyl chains with polar functional groups, and are ideal for the isolation of polar compounds.

Expand 4 Items
Laddar...
Solid phase extraction cartridges, HyperSep™ Diol

Solid phase extraction cartridges, HyperSep™ Diol

Supplier: Thermo Fisher Scientific

A short alkyl chains with polar functional groups are ideal for the isolation of polar compounds.

Expand 9 Items
Laddar...

Solid phase extraction cartridges, HyperSep™ Aminopropyl

Supplier: Thermo Fisher Scientific

A polar sorbent for both polar and anion exchange interactions.

Expand 9 Items
Laddar...

Solid phase extraction cartridges, Bond Elut™ CN-U

Supplier: VARIAN

Bond Elut CN-U is ideally suited for the extraction of polar compounds from a nonpolar matrix, such as hexane or oils. It is suitable for very polar analytes that may be irreversibly retained on SI or Diol (2OH) SPE phases.

Expand 4 Items
Laddar...
Solid phase extraction cartridges, HyperSep™ SCX

Solid phase extraction cartridges, HyperSep™ SCX

Supplier: Thermo Fisher Scientific

A strong cation exchange sorbent for extraction of charged basic compounds.

Expand 10 Items
Laddar...

Solid phase extraction cartridges, Bond Elut™ CN-E

Supplier: VARIAN

A medium polarity sorbent with many uses, Bond Elut™ CN-E is ideal for applications in which extremely non-polar compounds would be irreversibly retained on high carbon load sorbents such as C₈ and C₁₈. This endcapped version of the cyano sorbent is best utilised when extracting analytes from an aqueous matrix.

Expand 4 Items
Laddar...

Solid phase extraction cartridges, Bond Elut™ Mycotoxin

Supplier: VARIAN

Bond Elut™ Mycotoxin is a novel sorbent which cleans up food extracts for improved trichothecene and zearalenone analysis. Results are comparable or superior to competing methods, including immunoaffinity columns (IaC) and charcoal/alumina columns. The sorbent is a proprietary silica-based ion exchange material.

Expand 1 Items
Laddar...
Solid phase extraction cartridges, HyperSep™ C8

Solid phase extraction cartridges, HyperSep™ C8

Supplier: Thermo Fisher Scientific

HyperSep™ C8 cartridges, less retentive alternative to C18 for polar and nonpolar compounds.

Expand 8 Items
Laddar...
Solid phase extraction cartridges, Bond Elut™ C1

Solid phase extraction cartridges, Bond Elut™ C1

Supplier: VARIAN

Due to the methyl group and subsequent low carbon load, Bond Elut™ C1 is the least retentive of all alkyl group bonded phases for non-polar compounds. However, due to the extensive end capping of this sorbent to mask polar silanol activity, retention and elution of polar and multi-functional analytes can still be achieved. Typical applications include plasma, urine and aqueous samples.

Expand 3 Items
Laddar...
Solid phase extraction cartridges, HyperSep™ C18

Solid phase extraction cartridges, HyperSep™ C18

Supplier: Thermo Fisher Scientific

These columns feature a highly retentive alkyl-bonded phase for non polar to moderately polar compounds.

Expand 12 Items
Laddar...
Solid phase extraction cartridges, HyperSep™ Florisil

Solid phase extraction cartridges, HyperSep™ Florisil

Supplier: Thermo Fisher Scientific

Ideal for the isolation of polar compounds from non polar matrices.

Expand 9 Items
Laddar...
Solid phase extraction cartridges, HyperSep™ SAX

Solid phase extraction cartridges, HyperSep™ SAX

Supplier: Thermo Fisher Scientific

Strong anion exchange sorbent for extraction of weak acids.

Expand 9 Items
Laddar...

QuEChERS Dispersive Solid Phase Extraction (SPE) Kit

Supplier: Thermo Fisher Scientific

The QuEChERS Extraction Kit is designed for the efficient extraction of pesticides from food samples, ensuring compliance with the 2025 China Pharmacopeia.

Expand 1 Items
Laddar...

Solid phase extraction cartridges, Bond Elut™ PBA

Supplier: VARIAN

PBA is a unique sorbent consisting of a phenylboronic acid covalently linked to a silica gel surface. Covalent processes result in a higher retention to the sorbent surface than other mechanisms, resulting in superior clean-up. The boronate group has a high specificity for cis-diol containing compounds such as catechols, nucleic acids, low molecular weight proteins and carbohydrates.

Expand 6 Items
Laddar...
Solid phase extraction cartridges, Bond Elut™ AccuCAT

Solid phase extraction cartridges, Bond Elut™ AccuCAT

Supplier: VARIAN

Bond Elut AccuCAT cartridges are mixed bed SPE cartridges consisting of a strong cation exchange (SCX) and a strong anion exchange (SAX) sorbent packed into one bed. AccuCAT is effective for the extraction of acidic, basic and neutral analytes from urine and other biological samples. AccuCAT is particularly effective for catecholamine extraction from bio fluids.

Expand 6 Items
Laddar...

Solid phase extraction cartridges, Bond Elut™ PRS

Supplier: VARIAN

Bond Elut™ PRS is a strong cation exchange sorbent that is also relatively high in polarity. With no appreciable degree of hydrophobicity, in non-polar solvents, PRS is capable of polar and hydrogen bonding interactions. Due to the very low pKa of PRS, a high ionic strength eluent must be used, and so the use of PRS is recommended for weaker cationic species such as pyridinium compounds.

Expand 7 Items
Laddar...

Solid phase extraction cartridges, Bond Elut™ Plexa

Supplier: VARIAN

The water-wettable, hydroxylated exterior allows excellent flow, even with biological fluids. A gradient of polarity on the polymer surface shunts small analytes to the more hydrophobic centre of the polymer bead, where they are retained prior to the washing and elution steps. Plexa provides these performance enhancements due to a unique polymeric architecture with a non-retentive, hydroxylated, amide-free surface and a non-polar PS/DVB core for retaining small molecules.

Expand 11 Items
Laddar...

Solid phase extraction cartridges, Bond Elut™ CBA

Supplier: VARIAN

CBA is a mid-polarity sorbent and weak cation exchanger (pKa 4,8). It can be used with a wider range of counter-ions than lower pKa sorbents like SCX and will demonstrate easier elution of quaternary amine functionalised analytes.

Expand 8 Items
Laddar...

Solid phase extraction cartridges, Bond Elut™ PSA

Supplier: VARIAN

Bond Elut™ PSA is an alkylated amine sorbent that contains two different amino functionalities, one secondary and one primary. This gives a slightly higher pKa and ionic capacity compared to Bond Elut™ NH₂. The PSA functional group is a very effective bidentate ligand and is therefore an excellent sorbent for chelation applications. PSA has a significantly higher carbon load than most amino functional sorbents and thus is a better choice for polar compounds, which retain too strongly on Bond Elut™ NH₂.

Expand 8 Items
Laddar...
Empty solid phase extraction cartridges, Bond Elut™

Empty solid phase extraction cartridges, Bond Elut™

Supplier: VARIAN

Bond Elut empty SPE cartridges are made with high purity polypropylene for cleaner extracts.

Expand 6 Items
Laddar...
Accessories for empty solid phase extraction columns CHROMABOND®

Accessories for empty solid phase extraction columns CHROMABOND®

Supplier: MACHEREY-NAGEL

CHROMABOND®, Adapters (PVDF) for glass columns (3 and 6 ml)

Expand 16 Items
Laddar...

Solid phase extraction cartridges, Bond Elut™ Florisil

Supplier: VARIAN

Florisil is a magnesia-loaded silica gel, extremely polar in nature and ideal for the isolation of polar compounds from non-polar matrices.

Expand 15 Items
Laddar...
Solid phase extraction cartridges, Bond Elut™ C2

Solid phase extraction cartridges, Bond Elut™ C2

Supplier: VARIAN

Bond Elut™ C2 is a fairly non-polar sorbent because of the short chain length of the functional group. C2 is often used during the process of method development if analytes are retained too strongly on a C8 or C18 phase. The polarity of C2 is slightly lower than a cyano phase for polar interactions.

Expand 10 Items
Laddar...
Sortera efter