Fixed-angle titanium rotor package/assembly, TLA-120.1
Leverantör: Beckman Coulter
Om denna produkt
Major applications: Pelleting of subcellularfractions in 5 to 30 minutes; plasmid DNA separation in 3 hours.
2 Alternativ tillgängliga nedan
Product Details & Documents
Major applications: Pelleting of subcellularfractions in 5 to 30 minutes; plasmid DNA separation in 3 hours.
Specifications for Product Family
Specifikationer
- Catalog No:
- 521-3913
- 521-3977
- Kapacitet:
- 7,0 ml
- 7,0 ml
- No. of tubes accepted:
- 14×0 ml / 8×34 mm
- 14×0 ml / 8×34 mm
- Radie:
- 38,9 mm
- 38,9 mm
- Max. RPM:
- 120000
- 120000
Specifikationer
Product Family Options
Rotor package
Produktinformation
- FörTillgänglighetPrice
- 521-3913TLA-120.1 fixed-angle titanium rotor package, includes rotor, 1 box (BECM343776) thickwall polycarbonate tubes, 1 each (BECM348304) tube rack, (BECM346133) rotor vise/stand, (BECM927208) hemostats, (BECM824412 and BECM854519) O-rings, (BECM306812) Spinkote lubricant and (BECM355148) vacuum greaseTLA-120.1 fixed-angle titanium rotor package, includes rotor, 1 box (BECM343776) thickwall polycarbonate tubes, 1 each (BECM348304) tube rack, (BECM346133) rotor vise/stand, (BECM927208) hemostats, (BECM824412 and BECM854519) O-rings, (BECM306812) Spinkote lubricant and (BECM355148) vacuum greaseOptima MAX-XP benchtop ultracentrifuge, Optima TLX personal micro-ultracentrifuges, Optima MAX high-capacity personal micro-ultracentrifuges, and the discontinued TL-100 and Optima TL personal micro-ultracentrifugesLog in för att kolla tillgänglighet och ert prisLog in för att kolla tillgänglighet och ert pris1 * 1 Items1 * 1 Items - 146 913,00 kr146 913,00 kr1 * 1 Items146 913,00 krSpecifikationer:
More
Specifications
Cat. No.521-3913Kapacitet7,0 mlNo. of tubes accepted14×0 ml / 8×34 mmRadie38,9 mmMax. RPM120000
Rotor assembly
Produktinformation
- FörTillgänglighetPrice
- 521-3977TLA-120.1 rotor assembly, fixed-angle rotor, titanium. Major applications: Pelleting of subcellularfractions in 5-30 minutes; plasmid DNA separation in 3 hoursTLA-120.1 rotor assembly, fixed-angle rotor, titanium. Major applications: Pelleting of subcellularfractions in 5-30 minutes; plasmid DNA separation in 3 hoursFor use in the Optima MAX-XP benchtop ultracentrifuge, Optima TLX personal micro-ultracentrifuges, Optima MAX high-capacity personal micro-ultracentrifuges, and the discontinued TL-100 and Optima TL personal micro-ultracentrifugesLog in för att kolla tillgänglighet och ert prisLog in för att kolla tillgänglighet och ert pris1 * 1 Items1 * 1 Items - 142 010,00 kr142 010,00 kr1 * 1 Items142 010,00 krSpecifikationer: