Order Entry
Sweden
ContactUsLinkComponent
13 results for Autoradiografifilmer

You searched for: Autoradiografifilmer

Autoradiografifilmer

The autoradiography films and cassettes detect chemiluminescent labelled samples. These sheets provide maximum clarity and sensitivity, with great signal-to-noise ratios for increased detection effectiveness. Used for storage and transportation of the autoradiography films, the hard cassettes provide light-tight exposures at temperatures down to -70°C. Cassettes provide maximum contact between films and samples, and advanced emulsion technology in the films maximizes image resolution and background clarity.

Sort By
Film, CL-XPosure™

Film, CL-XPosure™

Supplier: Thermo Fisher Scientific

CL-XPosure™ Film is a clear blue X-ray film recommended for the detection and documentation of blotting assays.

Expand 2 Items
Loading...

Photographic step tablet

Supplier: Cytiva

Autoradiografifilm, Photographic step tablet

Expand 1 Items
Loading...
Film, Kodak BioMax® XAR

Film, Kodak BioMax® XAR

Supplier: CARESTREAM HEALTH

BioMax® XAR-film är en autoradiografifilm som är avsedd för användning med alla vanliga isotoper och kemiluminiscensmärkningar. Filmen har en emulsionsbestrykning på båda sidor av ett genomskinligt skikt och är lämplig för både direkt autoradiografi och exponering med förstärkningsskärmar, inklusive BioMax®-förstärkningsskärmar.

Expand 4 Items
Loading...
Film, Kodak BioMax® MS

Film, Kodak BioMax® MS

Supplier: CARESTREAM HEALTH

BioMax® MS-film är en autoradiografifilm med höga prestanda och maximal känslighet för allmänt bruk. Vid användning tillsammans med BioMax® TranScreen HE intensifierande skärm ger den 4 till 8 gånger bättre känslighet vid identifiering av ³²P jämfört med andra kombinationer av autoradiografifilm och intensifierande skärmar. Den här film/skärmkombinationen är idealisk för identifiering av Northern, Southern och dot blot-tillämpningar, i synnerhet om identifiering av lågintensiva prover eller minskad exponeringstid krävs.

Expand 1 Items
Loading...
Intensifying screens, BioMax® MS

Intensifying screens, BioMax® MS

Supplier: CARESTREAM HEALTH

The BioMax® MS intensifying screen is optimised for use with BioMax® MS film to maximise sensitivity for detection of ³²P and ¹²⁵I labelled samples.

Expand 2 Items
Loading...
Film, Kodak X-OMAT® LS

Film, Kodak X-OMAT® LS

Supplier: CARESTREAM HEALTH

X-OMAT® LS är en prisvärd, blåtonad film som är lämplig när den maximala prestandan hos BioMax® MR-, BioMax® MS- eller X-OMAT® AR-film inte är nödvändig. X-OMAT® LS-film är lämplig att användas med alla vanliga radioisotoper och kemiluminescenta givare. Filmen har dock en betydligt mindre detektionskänslighet än BioMax® autoradiografifilmer, vilket resulterar i längre exponeringstider.

Expand 2 Items
Loading...
Intensifying screens, BioMax® TranScreen HE

Intensifying screens, BioMax® TranScreen HE

Supplier: CARESTREAM HEALTH

Designed for use with gamma emitters such as ¹²⁵I and high-energy beta emitters, such as ³²P, the BioMax™ TranScreen HE intensifying screen offers the greatest sensitivity. When used in conjunction with the BioMax™ MS film, the system equals or exceeds the image quality of conventional autoradiography screen/film systems. By minimising the distances between the radioisotope and phosphor layer, it presents the phosphor to the emitting particles immediately, for less scattering and better spatial resolution.

Expand 4 Items
Loading...
Film för kemiluminiscent bildtagning, Kodak BioMax® Light

Film för kemiluminiscent bildtagning, Kodak BioMax® Light

Supplier: CARESTREAM HEALTH

BioMax® Light is a double emulsion film that provides maximum clarity and sensitivity for detection of chemiluminescent-labelled samples. BioMax® Light produces the highest signal-to-noise ratio of any Kodak film for detection of chemiluminescence. This film performs well with all brands of chemiluminescent kits. BioMax® Light film is suitable for direct and intensifying screen exposures with commonly used isotopes, though it provides lower sensitivity resulting in longer exposure times compared to BioMax® MS, and X-OMAT AR films for radioisotope detection.

Expand 4 Items
Loading...
Film, Amersham Hyperfilm™ MP

Film, Amersham Hyperfilm™ MP

Supplier: Cytiva

Amersham Hyperfilm™ MP is a multipurpose film constructed from a clear base coated on both sides with a photographic emulsion that is protected by an anti-scratch layer. The anti-scratch coating reduces the risk of visible artefacts (e.g., plastic wrap marks) and the clear colourless base results in easy reading of images, without compromising on sensitivity.

Expand 6 Items
Loading...
Film, Amersham Hyperfilm™ ECL™

Film, Amersham Hyperfilm™ ECL™

Supplier: Cytiva

Amersham™ Hyperfilm™ ECL™ is constructed from a clear base coated on both sides with a photographic emulsion that is protected by an anti-scratch layer. The anti-scratch coating reduces the risk of visible artefacts (e.g., plastic wrap marks) and the clear colourless base results in easy reading of images without compromising on sensitivity.

Expand 5 Items
Loading...
Kodak BioMax® MR

Kodak BioMax® MR

Supplier: CARESTREAM HEALTH

BioMax® MR är en enkelemulsionsfilm som ger maximal upplösning och känslighet för detektering av ³⁵S-, ³²P- och ¹⁴C-märkta prover. En emulsionsbestrykning på ena sidan av ett klart skikt ger maximal upplösning och bakgrundsklarhet i detekteringen av alla märkningar, vilket ger allmänt enklare och mer tillförlitlig avläsning av sekvenseringsgeler. BioMax®-film ger även maximal upplösning för direkt detektering av ³²P-märkta prov, vilket ger skarpare, klarare bandsignaler som möjliggör granskning av ytterst små detaljer. BioMax® MR-film är även lämplig för detektering av de flesta kemiluminiscensmärkta prover. BioMax® MR-film är inte lika känslig som BioMax® MS men ger maximal upplösning och rekommenderas för Western blot-tillämpningar med kemiluminiscens med relativt kortvarig exponering.

Expand 1 Items
Loading...

Storage phosphor screens and cassettes

Supplier: Cytiva

Storage phosphor screens capture latent images produced by ionising radiation (X-ray, β, and γ emissions from isotopes such as 14C, 3H, 125I, 131I, 32P, 35S, 33P, and more.). Upon laser-induced stimulation, light is emitted from the storage phosphor screen in proportion to the amount of radioactivity in the sample. The resulting digital image allows for quantitation of subtle signal intensity differences over a wide dynamic range using storage phosphor imaging systems such as Typhoon, Storm, and PhosphorImager. Typically, 50% to 90% less exposure time is required compared with an equivalent exposure to conventional film. Publication quality images are often obtained in a single exposure. They are reusable and are not degraded by repeated exposure to laboratory levels of radioactivity.

Expand 9 Items
Loading...

Electron micrography films, Kodak

Supplier: CARESTREAM HEALTH

These micrography films offer considerable latitude in performance and flexibility for most electron microscopy applications. They are suitable for medium-energy electrons (40 to 100 ky) and acceptable results can also be obtained at higher electron levels.

Expand 4 Items
Loading...
Sort By