About this item
To measure the 'spot concentrations' of mercaptan for use with an Accuro® pump. Uses include determination and measurement of concentration peaks, personal exposure in the inhalation area, detection of leaks in pipelines or gas installations, air analysis in sewers, shafts and confined spaces.
One stroke is equivalent to a volume of 100 ±5 ml of gas passing through the tube.
The standard measuring range is calibrated at 20 °C and 1013 hPa.
3 Options Available Below
Product Details & Documents
To measure the 'spot concentrations' of mercaptan for use with an Accuro® pump. Uses include determination and measurement of concentration peaks, personal exposure in the inhalation area, detection of leaks in pipelines or gas installations, air analysis in sewers, shafts and confined spaces.
One stroke is equivalent to a volume of 100 ±5 ml of gas passing through the tube.
The standard measuring range is calibrated at 20 °C and 1013 hPa.
Specifications for Product Family
Specifications
- Catalog No:
- 118-0322
- 151-0160
- 151-0182
- Model:
- Mercaptan 0.1/a
- Mercaptan 0.5/a
- Mercaptan 20/a
- Colour change:
- Yellow to red
- White to yellow
- White to yellow brown
- Humidity:
- 2 - 40 mg/l H₂O
- 3 - 15 mg/l H₂O
- 3 - 30 mg/l H₂O
- Measurement time:
- 3 minutes/40 seconds
- 8 minutes
- 2,5 minutes
- No. of strokes:
- 10 / 2
- 20
- 10
- Standard deviation:
- ±10 - 15 %
- ±10 - 15 %
- ±10 - 15 %
- Standard range:
- 0,1 - 2,5 / 3 - 15 ppm
- 0,5 - 5 ppm
- 2 - 100 ppm
- Temperature range:
- 5…40 °C
- 10…40 °C
- 0…50 °C
Specifications
Product Family Options
Product Information
- Parameter(s)RangeAvailabilityPrice
- 118-0322Mercaptan 0,1/aSpecifications:
More
Specifications
Cat. No.118-0322ModelMercaptan 0.1/aColour changeYellow to redHumidity2 - 40 mg/l H₂OMeasurement time3 minutes/40 secondsNo. of strokes10 / 2Standard deviation±10 - 15 %Standard range0,1 - 2,5 / 3 - 15 ppmTemperature range5…40 °C - 151-0160Mercaptan 0,5/aSpecifications:
More
Specifications
Cat. No.151-0160ModelMercaptan 0.5/aColour changeWhite to yellowHumidity3 - 15 mg/l H₂OMeasurement time8 minutesNo. of strokes20Standard deviation±10 - 15 %Standard range0,5 - 5 ppmTemperature range10…40 °C - 151-0182Mercaptan 20/aSpecifications:
More
Specifications
Cat. No.151-0182ModelMercaptan 20/aColour changeWhite to yellow brownHumidity3 - 30 mg/l H₂OMeasurement time2,5 minutesNo. of strokes10Standard deviation±10 - 15 %Standard range2 - 100 ppmTemperature range0…50 °C