Order Entry
Portugal
ContactUsLinkComponent
 

You searched for: Chromatography Columns

Chromatography Columns

Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.

Solid phase extraction cartridges, Bond Elut™ AccuCAT

Solid phase extraction cartridges, Bond Elut™ AccuCAT

Supplier: VARIAN

Bond Elut AccuCAT cartridges are mixed bed SPE cartridges consisting of a strong cation exchange (SCX) and a strong anion exchange (SAX) sorbent packed into one bed. AccuCAT is effective for the extraction of acidic, basic and neutral analytes from urine and other biological samples. AccuCAT is particularly effective for catecholamine extraction from bio fluids.

Expand 6 Items
Loading...
Capillary columns, Rxi®-5Sil MS (fused silica)

Capillary columns, Rxi®-5Sil MS (fused silica)

Supplier: Restek

Rxi®-5Sil MS stationary phase incorporates phenyl groups in the polymer backbone. This improves thermal stability, reduces bleed, and makes the phase less prone to oxidation. These columns are ideal for GC-MS applications requiring high sensitivity, including use in ion trap systems.

Expand 4 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ CH

Supplier: VARIAN

Bond Elut™ CH is a mid-polarity sorbent that exhibits unique selectivities for certain analytes. When employed as a non-polar sorbent, CH has the approximate polarity of a C₂ sorbent. Bond Elut™ CH is often a good choice when non-polar sorbents such as C₁₈, C₈ or C₂ do not provide the desired selectivity.

Expand 5 Items
Loading...
Preparative HPLC columns, Ultra Biphenyl

Preparative HPLC columns, Ultra Biphenyl

Supplier: Restek

These biphenyl columns offer a greater degree of dispersion than conventional phenyls and a greater degree of polarizability than phenyl hexyls, creating higher selectivity and a greater range of usability. Because of these heightened interactions, this column shows substantial increases in retention—especially for dipolar, unsaturated, or conjugated solutes—and enhanced orthogonal selectivity when using methanol mobile phases.

Expand 3 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ SI

Supplier: VARIAN

Native silica is generally regarded as the most polar SPE sorbent available. Bond Elut™ SI is particularly effective at separating compounds with a very similar structure. Applying the analytes in a non-polar solvent, then increasing the solvent polarity by increasing the concentration of a polar modifier, such as THF or ethyl acetate, delivers effective separations.

Expand 18 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ NH₂

Supplier: VARIAN

Bond Elut™ NH₂ is a weaker anion exchanger than sorbents such as SAX (a quaternary amine sorbent that is always charged) and is therefore a better choice for retention of very strong anions, such as sulfonic acids, which may retain irreversibly on a SAX sorbent. Similar to Diol and SI sorbents, Bond Elut™ NH₂ is excellent for the separation of structural isomers.

Expand 24 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ SAX

Supplier: VARIAN

Bond Elut™ SAX is a strong anion exchange sorbent ideally suited for the extraction of compounds such as carboxylic acids, which may not retain effectively on weak anion exchange sorbents. The sorbent is supplied in the chloride counter ion form. You can modify the selectivity of the phase by replacing the chloride ion with other anions, such as acetate and hydroxide.

Expand 29 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ C18 OH

Supplier: VARIAN

Bond Elut™ C18 OH is a non-end capped version of the octadecyl bonded phases that enables the silanols on the silica surface to be more active. This low-load C18 has well-controlled silanol activity that permits the fractionation of metabolites and enhances retention of basic compounds compared to an endcapped C18. The pore size makes it a good choice for peptide extraction.

Expand 4 Items
Loading...
Capillary columns, CP-Chirasil-Dex CB

Capillary columns, CP-Chirasil-Dex CB

Supplier: VARIAN

The CP-Chirasil-Dex CB phase consists of cyclodextrin directly bonded to dimethylpolysiloxane. This bond prevents the cyclodextrin from migrating to different locations in the surface film, delivering homogeneous enantioselectivity throughout the phase.

Expand 3 Items
Loading...
Capillary columns, CP-Sil

Capillary columns, CP-Sil

Supplier: VARIAN

The CP-Si™l line consists of a range of stationary phases which are based on a polysiloxane backbone. Functional groups are added to the polymer to introduce selectivity. Each polymer used for the CP-Sil line is manufactured in-house and is optimised to obtain highest degree of reproducibility.

Expand 190 Items
Loading...

Solid phase extraction cartridges, EnvirElut™

Supplier: VARIAN

EnvirElut™ sorbents are specially designed for the extraction of a wide range of compounds from aqueous matrices. EnvirElut™ PAH and Pesticides are available in standard SPE straight barrel cartridges, which can be used on conventional vacuum manifolds such as the Vac Elut SPS 24.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ PH

Supplier: VARIAN

Bond Elut™ PH is a non-polar bonded silica material which exhibits a different selectivity to alkyl or aliphatic functionalised phases such as C8 or cyclohexyl. The electron density present in the aromatic ring affords an enhancement in the retention of conjugated or aromatic ring-containing analytes due to desirable pi-pi interactions.

Expand 11 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ CN-U

Supplier: VARIAN

Bond Elut CN-U is ideally suited for the extraction of polar compounds from a nonpolar matrix, such as hexane or oils. It is suitable for very polar analytes that may be irreversibly retained on SI or Diol (2OH) SPE phases.

Expand 4 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ C8

Supplier: VARIAN

Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.

Expand 23 Items
Loading...

UHPLC columns, Pinnacle® DB IBD UHPLC (USP L68)

Supplier: Restek

An intrinsically base-deactivated (IBD) phase, containing a polar group within, or intrinsic to, the hydrocarbon bonded phase. Unique selectivity and a high level of base deactivation, while reducing or eliminating the need for mobile phase additives.

Expand 3 Items
Loading...
HPLC columns, PLRP-S

HPLC columns, PLRP-S

Supplier: VARIAN

The PLRP-S family of products consists of a range of pore sizes and particle sizes, all with identical chemistry and fundamental adsorptive characteristics. The particles are inherently hydrophobic so there is no bonded phase, alkyl ligand required for reversed-phase separations. This gives a highly reproducible material that is free from silanols and heavy metal ions. Within the extensive product range are columns suitable for analytical separations and preparative purifications.

Expand 41 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Sodium Sulphate Drying

Supplier: VARIAN

Bond Elut™ Jr cartridges have top and bottom Luer fittings allowing easy sample processing when used in conjunction with standard SPE cartridges. Bond Elut™ LRC cartridges have a large reservoir above the sorbent bed and are suitable for use on any standard SPE vacuum manifold.

Expand 5 Items
Loading...
UHPLC columns, Ultra Aqueous C18 (USP L1)

UHPLC columns, Ultra Aqueous C18 (USP L1)

Supplier: Restek

Aqueous C18 is a rugged, reversed-phase column with a well-balanced retention profile. It can effectively retain more types of solutes than a conventional C18 and is ideal for multicomponent LC-MS analyses. The general-purpose Aqueous C18 boasts high reproducibility and compatibility with many mobile phase conditions - even 100% aqueous. And when used with a gradient, it eliminates the all-too-common issue of multiple compounds eluting near the column void time.

Expand 12 Items
Loading...
HPLC columns, Viva biphenyl (USP L11)

HPLC columns, Viva biphenyl (USP L11)

Supplier: Restek

These biphenyl coulmns have a greater degree of dispersion than conventional phenyls and a greater degree of polarisability than phenyl hexyls, creating higher selectivity and a greater range of usability. With heightened interactions shows substantial increases in retention for dipolar, unsaturated, or conjugated solutes and enhanced orthogonal selectivity when using methanol mobile phases.

Expand 26 Items
Loading...
High temperature columns, VF-5ht and VF-5ht Ultimetal

High temperature columns, VF-5ht and VF-5ht Ultimetal

Supplier: VARIAN

The VF-5ht improves the analysis of high boiling compounds by exhibiting low bleed, even at high temperatures. Based on ultra-low bleed FactorFour technology, VF-5ht provides unmatched selectivity, sensitivity, and accuracy for the analysis of high-molecular weight compounds.

Expand 14 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ PSA

Supplier: VARIAN

Bond Elut™ PSA is an alkylated amine sorbent that contains two different amino functionalities, one secondary and one primary. This gives a slightly higher pKa and ionic capacity compared to Bond Elut™ NH₂. The PSA functional group is a very effective bidentate ligand and is therefore an excellent sorbent for chelation applications. PSA has a significantly higher carbon load than most amino functional sorbents and thus is a better choice for polar compounds, which retain too strongly on Bond Elut™ NH₂.

Expand 8 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Certify

Supplier: VARIAN

The Bond Elut™ Certify extraction cartridge utilises a packed bed consisting of a special, non-polar C8 sorbent and a strong cation exchanger (SCX). Certify is most commonly used to extract basic (cationic) drugs from urine and blood, but it is also very effective for extraction of a wide range of compounds from a diverse range of aqueous matrices.

Expand 33 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Diol

Supplier: VARIAN

Bond Elut™ Diol (2OH) resembles unbonded silica in its tendency for strong hydrogen bonding with analytes. 2OH can also be employed in the non-polar mode because the hydrocarbon spacer on its functional group provides enough non-polar character for retention of hydrophobic analytes. Bond Elut™ Diol is a listed SPE device for the DIN 14333-1 method on benzimidazole fungicides.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ CN-E

Supplier: VARIAN

A medium polarity sorbent with many uses, Bond Elut™ CN-E is ideal for applications in which extremely non-polar compounds would be irreversibly retained on high carbon load sorbents such as C₈ and C₁₈. This endcapped version of the cyano sorbent is best utilised when extracting analytes from an aqueous matrix.

Expand 4 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ LMS

Supplier: VARIAN

Bond Elut™ LMS polymeric sorbent lets you elute without having to add amine modifiers, buffers, or acids. The elimination of secondary interactions means that elution of analytes can be achieved with pure organic solvents or HPLC mobile phase-compatible solvent mixtures of low ionic strength. These characteristics are crucial to allow compatibility with LC/MS or other delicate analytical techniques.

Expand 6 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ DEA

Supplier: VARIAN

Bond Elut™ DEA bears some resemblance to Bond Elut™ NH₂ in its properties but with a slightly lower capacity as an anion exchange sorbent. DEA has a moderately non-polar character due to the alkyl side chains on the amino functionality. These groups still afford a medium level of polarity, higher than C₈ but less polar than C₂ or CN-E.

Expand 11 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ Plexa PCX

Supplier: VARIAN

Bond Elut™ Plexa PCX uses a polymeric cation exchange resin that combines the outstanding properties of Bond Elut™ Plexa - superior flow characteristics and improved analytical performance - with strong cation exchange functionalities. This mixed-mode SPE sorbent removes neutral and acidic interferences from the matrix, concentrates basic analytes and therefore improves sensitivity in the determination of basic compounds.

Expand 11 Items
Loading...
Capillary columns, CP-Al₂O₃/Na₂SO₄

Capillary columns, CP-Al₂O₃/Na₂SO₄

Supplier: VARIAN

CP-Al₂O₃/Na₂SO₄ is an aluminum oxide PLOT column that offers high selectivity for separating ppm levels of C₁ to C₅ hydrocarbons in a main stream of C₁ to C₅ hydrocarbons. The Na₂SO₄ deactivation salt provides a polar Al₂O₃ surface, so that unsaturated compounds such as ethylene and acetylene are retained longer. These columns analyse more compounds in a single run than packed columns, while still delivering higher resolution and faster analysis times. When compared to liquid stationary phases, CP-Al₂O₃ provides increased selectivity and allows all C₁ to C₅ hydrocarbon isomers to be separated. CP-Al₂O₃ operates without the need for sub-ambient cooling.

Expand 6 Items
Loading...
Solid phase extraction cartridges, Bond Elut™ C18

Solid phase extraction cartridges, Bond Elut™ C18

Supplier: VARIAN

Bond Elut™ C18 is the most hydrophobic, bonded silica sorbent in the Bond Elut™ range. It is the most popular SPE sorbent because of its extremely retentive nature for non-polar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices. When analysing small to intermediate molecules, Bond Elut™ C18 can be used for desalting aqueous matrices prior to ion exchange, as salts pass through the sorbent unretained.

Expand 43 Items
Loading...

Solid phase extraction cartridges, Bond Elut™ PBA

Supplier: VARIAN

PBA is a unique sorbent consisting of a phenylboronic acid covalently linked to a silica gel surface. Covalent processes result in a higher retention to the sorbent surface than other mechanisms, resulting in superior clean-up. The boronate group has a high specificity for cis-diol containing compounds such as catechols, nucleic acids, low molecular weight proteins and carbohydrates.

Expand 5 Items
Loading...
Recommended for You