You searched for: Chromatography Columns
Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.
Preparative HPLC columns, Ultra Biphenyl
Supplier: Restek
These biphenyl columns offer a greater degree of dispersion than conventional phenyls and a greater degree of polarizability than phenyl hexyls, creating higher selectivity and a greater range of usability. Because of these heightened interactions, this column shows substantial increases in retention—especially for dipolar, unsaturated, or conjugated solutes—and enhanced orthogonal selectivity when using methanol mobile phases.
Expand 3 Items
Capillary columns, CP-Chirasil Val
Supplier: VARIAN
The CP-Chirasil Val columns are designed for the separation of optically active compounds, especially amino acids. They have lower bleed levels than other phases with a Tmax of 200 °C, isothermally and programmed.
Expand 3 Items
Solid phase extraction cartridges, Bond Elut™ Mycotoxin
Supplier: VARIAN
Bond Elut™ Mycotoxin is a novel sorbent which cleans up food extracts for improved trichothecene and zearalenone analysis. Results are comparable or superior to competing methods, including immunoaffinity columns (IaC) and charcoal/alumina columns. The sorbent is a proprietary silica-based ion exchange material.
Expand 1 Items
Analytical HPLC columns, Ultra Amino (USP L8)
Supplier: Restek
Ultra amino columns are made of high-purity, spherical shaped type-B silica that minimises activity and creates high-density bonding. These columns are designed for selective and reliable HPLC applications. Aminopropylsilane provides reproducible retention and efficiency for normal-phase or HILIC analysis of simple sugars.
Expand 10 Items
HPLC columns, Polaris™ C18-ether
Supplier: VARIAN
Polaris™ C18-ether phase has a rapid high resolution separation based on ultra pure silica to which alkyl chains and polar modifications are attached.
Expand 26 Items
Solid phase extraction cartridges, Bond Elut™ AccuCAT
Supplier: VARIAN
Bond Elut AccuCAT cartridges are mixed bed SPE cartridges consisting of a strong cation exchange (SCX) and a strong anion exchange (SAX) sorbent packed into one bed. AccuCAT is effective for the extraction of acidic, basic and neutral analytes from urine and other biological samples. AccuCAT is particularly effective for catecholamine extraction from bio fluids.
Expand 6 Items
Solid phase extraction cartridges, Bond Elut™ CH
Supplier: VARIAN
Bond Elut™ CH is a mid-polarity sorbent that exhibits unique selectivities for certain analytes. When employed as a non-polar sorbent, CH has the approximate polarity of a C₂ sorbent. Bond Elut™ CH is often a good choice when non-polar sorbents such as C₁₈, C₈ or C₂ do not provide the desired selectivity.
Expand 5 Items
Solid phase extraction cartridges, Bond Elut™ C8
Supplier: VARIAN
Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.
Expand 23 Items
Capillary columns, CP-Chirasil-Dex CB
Supplier: VARIAN
The CP-Chirasil-Dex CB phase consists of cyclodextrin directly bonded to dimethylpolysiloxane. This bond prevents the cyclodextrin from migrating to different locations in the surface film, delivering homogeneous enantioselectivity throughout the phase.
Expand 3 Items
Capillary columns, CP-Sil
Supplier: VARIAN
The CP-Si™l line consists of a range of stationary phases which are based on a polysiloxane backbone. Functional groups are added to the polymer to introduce selectivity. Each polymer used for the CP-Sil line is manufactured in-house and is optimised to obtain highest degree of reproducibility.
Expand 190 Items
Solid phase extraction cartridges, EnvirElut™
Supplier: VARIAN
EnvirElut™ sorbents are specially designed for the extraction of a wide range of compounds from aqueous matrices. EnvirElut™ PAH and Pesticides are available in standard SPE straight barrel cartridges, which can be used on conventional vacuum manifolds such as the Vac Elut SPS 24.
Expand 6 Items
Capillary columns, Rxi®-5Sil MS (fused silica)
Supplier: Restek
Rxi®-5Sil MS stationary phase incorporates phenyl groups in the polymer backbone. This improves thermal stability, reduces bleed, and makes the phase less prone to oxidation. These columns are ideal for GC-MS applications requiring high sensitivity, including use in ion trap systems.
Expand 4 Items
UHPLC columns, Pinnacle® DB IBD UHPLC (USP L68)
Supplier: Restek
An intrinsically base-deactivated (IBD) phase, containing a polar group within, or intrinsic to, the hydrocarbon bonded phase. Unique selectivity and a high level of base deactivation, while reducing or eliminating the need for mobile phase additives.
Expand 3 Items
Solid phase extraction cartridges, Bond Elut™ PH
Supplier: VARIAN
Bond Elut™ PH is a non-polar bonded silica material which exhibits a different selectivity to alkyl or aliphatic functionalised phases such as C8 or cyclohexyl. The electron density present in the aromatic ring affords an enhancement in the retention of conjugated or aromatic ring-containing analytes due to desirable pi-pi interactions.
Expand 11 Items
HPLC columns, PLRP-S
Supplier: VARIAN
The PLRP-S family of products consists of a range of pore sizes and particle sizes, all with identical chemistry and fundamental adsorptive characteristics. The particles are inherently hydrophobic so there is no bonded phase, alkyl ligand required for reversed-phase separations. This gives a highly reproducible material that is free from silanols and heavy metal ions. Within the extensive product range are columns suitable for analytical separations and preparative purifications.
Expand 41 Items
UHPLC columns, Ultra Aqueous C18 (USP L1)
Supplier: Restek
Aqueous C18 is a rugged, reversed-phase column with a well-balanced retention profile. It can effectively retain more types of solutes than a conventional C18 and is ideal for multicomponent LC-MS analyses. The general-purpose Aqueous C18 boasts high reproducibility and compatibility with many mobile phase conditions - even 100% aqueous. And when used with a gradient, it eliminates the all-too-common issue of multiple compounds eluting near the column void time.
Expand 12 Items
Solid phase extraction cartridges, Bond Elut™ Sodium Sulphate Drying
Supplier: VARIAN
Bond Elut™ Jr cartridges have top and bottom Luer fittings allowing easy sample processing when used in conjunction with standard SPE cartridges. Bond Elut™ LRC cartridges have a large reservoir above the sorbent bed and are suitable for use on any standard SPE vacuum manifold.
Expand 5 Items
HPLC columns, Viva biphenyl (USP L11)
Supplier: Restek
These biphenyl coulmns have a greater degree of dispersion than conventional phenyls and a greater degree of polarisability than phenyl hexyls, creating higher selectivity and a greater range of usability. With heightened interactions shows substantial increases in retention for dipolar, unsaturated, or conjugated solutes and enhanced orthogonal selectivity when using methanol mobile phases.
Expand 26 Items
Solid phase extraction cartridges, Bond Elut™ CN-U
Supplier: VARIAN
Bond Elut CN-U is ideally suited for the extraction of polar compounds from a nonpolar matrix, such as hexane or oils. It is suitable for very polar analytes that may be irreversibly retained on SI or Diol (2OH) SPE phases.
Expand 4 Items
Solid phase extraction cartridges, Bond Elut™ Certify
Supplier: VARIAN
The Bond Elut™ Certify extraction cartridge utilises a packed bed consisting of a special, non-polar C8 sorbent and a strong cation exchanger (SCX). Certify is most commonly used to extract basic (cationic) drugs from urine and blood, but it is also very effective for extraction of a wide range of compounds from a diverse range of aqueous matrices.
Expand 33 Items
Solid phase extraction cartridges, Bond Elut™ PSA
Supplier: VARIAN
Bond Elut™ PSA is an alkylated amine sorbent that contains two different amino functionalities, one secondary and one primary. This gives a slightly higher pKa and ionic capacity compared to Bond Elut™ NH₂. The PSA functional group is a very effective bidentate ligand and is therefore an excellent sorbent for chelation applications. PSA has a significantly higher carbon load than most amino functional sorbents and thus is a better choice for polar compounds, which retain too strongly on Bond Elut™ NH₂.
Expand 8 Items
Solid phase extraction cartridges, Bond Elut™ Diol
Supplier: VARIAN
Bond Elut™ Diol (2OH) resembles unbonded silica in its tendency for strong hydrogen bonding with analytes. 2OH can also be employed in the non-polar mode because the hydrocarbon spacer on its functional group provides enough non-polar character for retention of hydrophobic analytes. Bond Elut™ Diol is a listed SPE device for the DIN 14333-1 method on benzimidazole fungicides.
Expand 6 Items
Solid phase extraction cartridges, Bond Elut™ LMS
Supplier: VARIAN
Bond Elut™ LMS polymeric sorbent lets you elute without having to add amine modifiers, buffers, or acids. The elimination of secondary interactions means that elution of analytes can be achieved with pure organic solvents or HPLC mobile phase-compatible solvent mixtures of low ionic strength. These characteristics are crucial to allow compatibility with LC/MS or other delicate analytical techniques.
Expand 6 Items
High temperature columns, VF-5ht and VF-5ht Ultimetal
Supplier: VARIAN
The VF-5ht improves the analysis of high boiling compounds by exhibiting low bleed, even at high temperatures. Based on ultra-low bleed FactorFour technology, VF-5ht provides unmatched selectivity, sensitivity, and accuracy for the analysis of high-molecular weight compounds.
Expand 14 Items
Solid phase extraction cartridges, Bond Elut™ CN-E
Supplier: VARIAN
A medium polarity sorbent with many uses, Bond Elut™ CN-E is ideal for applications in which extremely non-polar compounds would be irreversibly retained on high carbon load sorbents such as C₈ and C₁₈. This endcapped version of the cyano sorbent is best utilised when extracting analytes from an aqueous matrix.
Expand 4 Items
Solid phase extraction cartridges, Bond Elut™ DEA
Supplier: VARIAN
Bond Elut™ DEA bears some resemblance to Bond Elut™ NH₂ in its properties but with a slightly lower capacity as an anion exchange sorbent. DEA has a moderately non-polar character due to the alkyl side chains on the amino functionality. These groups still afford a medium level of polarity, higher than C₈ but less polar than C₂ or CN-E.
Expand 11 Items
Solid phase extraction cartridges, Bond Elut™ Plexa PCX
Supplier: VARIAN
Bond Elut™ Plexa PCX uses a polymeric cation exchange resin that combines the outstanding properties of Bond Elut™ Plexa - superior flow characteristics and improved analytical performance - with strong cation exchange functionalities. This mixed-mode SPE sorbent removes neutral and acidic interferences from the matrix, concentrates basic analytes and therefore improves sensitivity in the determination of basic compounds.
Expand 11 Items
Solid phase extraction cartridges, Bond Elut™ C18
Supplier: VARIAN
Bond Elut™ C18 is the most hydrophobic, bonded silica sorbent in the Bond Elut™ range. It is the most popular SPE sorbent because of its extremely retentive nature for non-polar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices. When analysing small to intermediate molecules, Bond Elut™ C18 can be used for desalting aqueous matrices prior to ion exchange, as salts pass through the sorbent unretained.
Expand 43 Items
Solid phase extraction cartridges, Bond Elut™ PBA
Supplier: VARIAN
PBA is a unique sorbent consisting of a phenylboronic acid covalently linked to a silica gel surface. Covalent processes result in a higher retention to the sorbent surface than other mechanisms, resulting in superior clean-up. The boronate group has a high specificity for cis-diol containing compounds such as catechols, nucleic acids, low molecular weight proteins and carbohydrates.
Expand 5 Items
Solid phase extraction cartridges, Bond Elut™ PRS
Supplier: VARIAN
Bond Elut™ PRS is a strong cation exchange sorbent that is also relatively high in polarity. With no appreciable degree of hydrophobicity, in non-polar solvents, PRS is capable of polar and hydrogen bonding interactions. Due to the very low pKa of PRS, a high ionic strength eluent must be used, and so the use of PRS is recommended for weaker cationic species such as pyridinium compounds.