Order Entry
Puerto Rico
ContactUsLinkComponent
n-Hexane ≥95%, Supelco®
Flammable
Health
Irritant
Environment
n-Hexane ≥95%, Supelco®
Supplier:  MilliporeSigma
Certificates
undefined
Flammable
Health
Irritant
Environment
n-Hexane ≥95%, Supelco®
Supplier:  MilliporeSigma
Certificates

Some Products May Appear Restricted

To ensure a smooth and speedy checkout, please log in to your account. Some items may show as restricted simply because you're not logged in.

If you do not have an account, you can register using our registration webform (https://www.avantorsciences.com/us/en/login/register)

 

If you're still seeing restrictions after logging in, certain products—like chemicals or medical devices—require additional account verification steps to be able to place an order. Some items may additionally require a specific license or customer documentation;  additional documentation will be requested for these items prior to shipment. 

Specification Test Results

  • Appearance:
    Clear liquid, free from particulates
  • Color (APHA):
    10 max
  • Residue after evaporation:
    5ppm max
  • Infrared spectrum:
    Conforms
  • Assay (n-hexane):
    95% min
  • Sulfur compounds (as S):
    0.005% max
  • Thiophene:
    To pass test
  • Water-soluble titrable acid:
    0.0003meq/g max
  • Assay (total hexane isomers + methylcyclopentane):
    99.0% min
  • UV Abs. at 200nm:
    1.0AU max
  • UV Abs. at 210 nm:
    0.30AU max
  • UV Abs. at 220 nm:
    0.10AU max
  • UV Abs. at 230 nm:
    0.05AU max
  • UV Abs. at 240 nm:
    0.04AU max
  • UV Abs. at 250 nm:
    0.02AU max
  • UV Abs. at 270 nm:
    0.01AU max
  • UV Abs. at 300 nm:
    0.01AU max
  • UV Abs. at 350 nm:
    0.01AU max
  • UV Cut-off:
    200nm max
  • Water (H2O):
    0.01% max

Specification Test Results