Order Entry
Puerto Rico
ContactUsLinkComponent
FiveEasy™ / FiveEasy Plus™ Benchtop Conductivity Meters, METTLER TOLEDO®
FiveEasy™ / FiveEasy Plus™ Benchtop Conductivity Meters, METTLER TOLEDO®
Supplier:  Mettler Toledo
Certificates
undefined
FiveEasy™ / FiveEasy Plus™ Benchtop Conductivity Meters, METTLER TOLEDO®
Supplier:  Mettler Toledo

Specifications

  • Catalog No:
  • 10821-426
  • 10821-424
  • 10821-422
  • 10821-420
  • Model:
  • FiveEasy Plus FP30-standard kit with LE703 sensor, conductivity; USB, RS232 interfaces
  • FiveEasy Plus™ FP30-meter (meter only), conductivity; USB, RS232 interfaces
  • FiveEasy F30-standard kit with LE703 sensor, conductivity
  • F30
  • Conductivity Range:
  • 0.00 µS/cm…500.0 mS/cm
  • 0.00 µS/cm…500.0 mS/cm
  • 0.00 µS/cm…200.0 mS/cm
  • 0.00 µS/cm…200.0 mS/cm
  • Conductivity Resolution:
  • Automatic range
  • Automatic range
  • Automatic range
  • Automatic range
  • Conductivity Accuracy:
  • ±0.5% of the measured value
  • ±0.5% of the measured value
  • ±0.5% of the measured value
  • ±0.5% of the measured value
  • Conductivity Calibration:
  • 1 point, 3 predefined standards, manual cell constant input
  • 1 point, 3 predefined standards, manual cell constant input
  • 1 point, 3 predefined standards
  • 1 point, 3 predefined standards
  • Conductivity Reference Temperature:
  • 20 or 25 °C
  • 20 or 25 °C
  • 20 or 25 °C
  • 20 or 25 °C
  • Salinity Range:
  • 0.00…42.00 psu
  • 0.00…42.00 psu
  • Salinity Resolution:
  • 0.01 psu
  • 0.01 psu
  • Salinity Accuracy:
  • ±0.5% of the measured value
  • ±0.5% of the measured value
  • TDS Range:
  • 0.0 mg/L…300.0 g/L
  • 0.0 mg/L…300.0 g/L
  • 0.00 mg/L…200.0 g/L
  • 0.00 mg/L…200.0 g/L
  • TDS Resolution:
  • Automatic range
  • Automatic range
  • Automatic range
  • Automatic range
  • TDS Accuracy:
  • ±0.5% of the measured value
  • ±0.5% of the measured value
  • ±0.5% of the measured value
  • ±0.5% of the measured value
  • Temperature Range:
  • −5.0…105.0 °C (23.0…221.0 °F)
  • −5.0…105.0 °C (23.0…221.0 °F)
  • 0.0…100 °C (32.0…212.0 °F)
  • 0.0…100 °C (32.0…212.0 °F)
  • Temperature Resolution:
  • 0.1 °C
  • 0.1 °C
  • 0.1 °C
  • 0.1 °C
  • Temperature Accuracy:
  • ±0.3 °C
  • ±0.3 °C
  • ±0.5 °C
  • ±0.5 °C
  • Temperature Compensation:
  • Linear correction factor: 0.00…10.00%/°C
  • Linear correction factor: 0.00…10.00%/°C
  • Linear correction factor: 0.00…10.00%/°C
  • Linear correction factor: 0.00…10.00%/°C
  • Data Logging Capacity:
  • 200 measurements, current calibration
  • 200 measurements, current calibration
  • Current calibration
  • Current calibration
  • Connections:
  • Mini-DIN (NTC 30 kΩ), RS232, USB
  • Mini-DIN (NTC 30 kΩ), RS232, USB
  • Mini-DIN (NTC 30 kΩ)
  • Mini-DIN (NTC 30 kΩ)
  • Power supply:
  • 100…240 V/50…60 Hz, 12 VDC
  • 100…240 V/50…60 Hz, 12 VDC
  • 100…240 V/50…60 Hz, 12 VDC
  • 100…240 V/50…60 Hz, 12 VDC
  • Display:
  • 4.3" segmented LCD
  • 4.3" segmented LCD
  • 4.3" segmented LCD
  • 4.3" segmented LCD
  • Alarm:
  • Acoustic/visual
  • Acoustic/visual
  • Acoustic/visual
  • Acoustic/visual
  • Dimensions:
  • 227 × 147 × 70 mm
  • 227 × 147 × 70 mm
  • 227 × 147 × 70 mm
  • 227 × 147 × 70 mm
  • Weight:
  • 0.63 kg
  • 0.63 kg
  • 0.63 kg
  • 0.63 kg

Specifications