Ideal for low-flow, low-pressure applications where precision is needed.

  • Flow ranges from 0.05 uL/min up to 70.56 ml/min
  • Built-in program lets you enter up to eight commands to perform a variety of functions—you can even repeat commands up to ten times; all settings are stored in nonvolatile memory
  • Backlit alphanumeric LCD ste

Program flow rate hold, pause, and change of direction; each command can be set to run for up to 12 hours. You can even program infusion/withdrawal pumps to sequence operations: either withdrawal followed by infusion or infusion followed by withdrawal. Ch

Delivery information: Includes a 6-ft cord with grounded plug (U.S. standard plug on 115 VAC model and European plug on 230 VAC models).

Specifications for Product Family

Specifications

  • Model:
  • 74900-60
  • 74900-65
  • 74900-65
  • 74900-80
  • 74900-85
  • 74900-85
  • 74901-00
  • 74901-05
  • 74901-15
  • Accuracy:
  • ±1.0%
  • ±1.0%
  • ±1.0%
  • ±1.0%
  • ±1.0%
  • ±1.0%
  • ±0.5%
  • ±0.5%
  • ±0.5%
  • Input:
  • Baud rate: four settings up to 9600
  • Baud rate: four settings up to 9600
  • Baud rate: four settings up to 9600
  • Linear force:
  • 40 lbs.
  • 40 lbs.
  • 40 lbs.
  • 40 lbs.
  • 40 lbs.
  • 40 lbs.
  • 40 lbs.
  • 40 lbs.
  • 40 lbs.
  • Reproducibility:
  • ±0.1%
  • ±0.1%
  • ±0.1%
  • ±0.1%
  • ±0.1%
  • ±0.1%
  • ±0.2%
  • ±0.2%
  • ±0.2%
  • Syringe size accepted:
  • 10 µl - 140 ml
  • 10 µl - 140 ml
  • 10 µl - 140 ml
  • 10 µl - 140 ml
  • 10 µl - 140 ml
  • 10 µl - 140 ml
  • 10 µl - 140 ml
  • 10 µl - 140 ml
  • 10 µl - 140 ml
  • Syringe travel rate:
  • <126.7"
  • <126.7"
  • <126.7"
  • Warranty:
  • 1 year
  • 1 year
  • 1 year
  • 1 year
  • 1 year
  • 1 year
  • 1 year
  • 1 year

Specifications

Product Family Options

Product Information

  • Height
    Length
    Width
    Power
    Max. Flow Rate Per Syringe
    No. of Syringes
    Availability
    Price
  • DUP-DO-NOT-USE 490
    Infusion Pump, Dual-Syringe, Programmable; 115 VAC
    Infusion Pump, Dual-Syringe, Programmable; 115 VAC
    15.2 cm (6")
    27.94 cm (11")
    228.6 mm (9")
    115 VAC
    2
    Discontinued
    Specifications:
    More
    Specifications
    Cat. No.
    DUP-DO-NOT-USE 490
    Model
    74900-60
    Accuracy
    ±1.0%
    Input
    Linear force
    40 lbs.
    Reproducibility
    ±0.1%
    Syringe size accepted
    10 µl - 140 ml
    Syringe travel rate
    Warranty
    1 year
  • DUP-DO-NOT-USE 491
    Infusion Pump, Dual-Syringe, Programmable; 230 VAC
    Infusion Pump, Dual-Syringe, Programmable; 230 VAC
    15.2 cm (6")
    27.94 cm (11")
    228.6 mm (9")
    230 VAC
    2
    Discontinued
    Specifications:
    CE Compliant
    More
    Specifications
    Cat. No.
    DUP-DO-NOT-USE 491
    Model
    74900-65
    Accuracy
    ±1.0%
    Input
    Linear force
    40 lbs.
    Reproducibility
    ±0.1%
    Syringe size accepted
    10 µl - 140 ml
    Syringe travel rate
    Warranty
    1 year
    CE Compliant
  • MFLX74900-65
    Infusion Pump, Dual-Syringe, Programmable; 230 VAC
    Infusion Pump, Dual-Syringe, Programmable; 230 VAC
    15.2 cm (6")
    27.94 cm (11")
    228.6 mm (9")
    230 VAC
    2
    Log in for availability
    Log in for availability
    Each
    Each - $5,700.00
    $5,700.00
    Each
       $5,700.00

    Specifications:
    CE Compliant
    Irregular Voltage
    More
    Specifications
    Cat. No.
    MFLX74900-65
    Model
    74900-65
    Accuracy
    ±1.0%
    Input
    Linear force
    40 lbs.
    Reproducibility
    ±0.1%
    Syringe size accepted
    10 µl - 140 ml
    Syringe travel rate
    Warranty
    1 year
    CE Compliant
    Irregular Voltage
  • DUP-DO-NOT-USE 080
    Infusion Pump, Ten-Syringe Capacity; 115 VAC 50/60 Hz
    Infusion Pump, Ten-Syringe Capacity; 115 VAC 50/60 Hz
    15.2 cm (6")
    27.94 cm (11")
    304.8 mm (12")
    115 VAC
    10
    Discontinued
    Specifications:
    More
    Specifications
    Cat. No.
    DUP-DO-NOT-USE 080
    Model
    74900-80
    Accuracy
    ±1.0%
    Input
    Linear force
    40 lbs.
    Reproducibility
    ±0.1%
    Syringe size accepted
    10 µl - 140 ml
    Syringe travel rate
    Warranty
    1 year
  • DUP-DO-NOT-USE 085
    Infusion Pump, Ten-Syringe Capacity; 230 VAC 50/60 Hz
    Infusion Pump, Ten-Syringe Capacity; 230 VAC 50/60 Hz
    15.2 cm (6")
    27.94 cm (11")
    304.8 mm (12")
    230 VAC
    10
    Discontinued
    Specifications:
    CE Compliant
    More
    Specifications
    Cat. No.
    DUP-DO-NOT-USE 085
    Model
    74900-85
    Accuracy
    ±1.0%
    Input
    Linear force
    40 lbs.
    Reproducibility
    ±0.1%
    Syringe size accepted
    10 µl - 140 ml
    Syringe travel rate
    Warranty
    1 year
    CE Compliant
  • MFLX74900-85
    Infusion Pump, Ten-Syringe Capacity; 230 VAC 50/60 Hz
    Infusion Pump, Ten-Syringe Capacity; 230 VAC 50/60 Hz
    15.2 cm (6")
    27.94 cm (11")
    304.8 mm (12")
    230 VAC
    10
    Discontinued
    Specifications:
    CE Compliant
    Irregular Voltage
    More
    Specifications
    Cat. No.
    MFLX74900-85
    Model
    74900-85
    Accuracy
    ±1.0%
    Input
    Linear force
    40 lbs.
    Reproducibility
    ±0.1%
    Syringe size accepted
    10 µl - 140 ml
    Syringe travel rate
    Warranty
    1 year
    CE Compliant
    Irregular Voltage
  • DUP-DO-NOT-USE 010
    Infusion/Withdrawal Pump, Dual-Syringe, Programmable; 115 VAC
    Infusion/Withdrawal Pump, Dual-Syringe, Programmable; 115 VAC
    23.5 cm (9.25")
    27.94 cm (11")
    127 mm (5")
    115 VAC
    147 ml/min
    2
    Discontinued
    Specifications:
    More
    Specifications
    Cat. No.
    DUP-DO-NOT-USE 010
    Model
    74901-00
    Accuracy
    ±0.5%
    Input
    Baud rate: four settings up to 9600
    Linear force
    40 lbs.
    Reproducibility
    ±0.2%
    Syringe size accepted
    10 µl - 140 ml
    Syringe travel rate
    <126.7"
    Warranty
    1 year
  • MFLX74901-05
    Infusion/Withdrawal pump, Dual-Syringe, Programmable; 230 VAC
    Infusion/Withdrawal pump, Dual-Syringe, Programmable; 230 VAC
    23.5 cm (9.25")
    27.94 cm (11")
    127 mm (5")
    230 VAC
    147 ml/min
    2
    Discontinued
    Specifications:
    CE Compliant
    Irregular Voltage
    More
    Specifications
    Cat. No.
    MFLX74901-05
    Model
    74901-05
    Accuracy
    ±0.5%
    Input
    Baud rate: four settings up to 9600
    Linear force
    40 lbs.
    Reproducibility
    ±0.2%
    Syringe size accepted
    10 µl - 140 ml
    Syringe travel rate
    <126.7"
    Warranty
    CE Compliant
    Irregular Voltage
  • MFLX74901-15
    Infusion/Withdrawal Pump, Ten-Syringe, Programmable; 230 VAC
    Infusion/Withdrawal Pump, Ten-Syringe, Programmable; 230 VAC
    30.48 cm (12")
    27.94 cm (11")
    127 mm (5")
    230 VAC
    147 ml/min
    10
    Discontinued
    Specifications:
    CE Compliant
    More
    Specifications
    Cat. No.
    MFLX74901-15
    Model
    74901-15
    Accuracy
    ±0.5%
    Input
    Baud rate: four settings up to 9600
    Linear force
    40 lbs.
    Reproducibility
    ±0.2%
    Syringe size accepted
    10 µl - 140 ml
    Syringe travel rate
    <126.7"
    Warranty
    1 year
    CE Compliant
Accessories

Product Information

  • Catalog #
    Availability
    Price
  • Pumps, Syringe Pumps Daisy Chain Cable for 74901-80 Dual Drive Syringe Pump
    Pumps, Syringe Pumps Daisy Chain Cable for 74901-80 Dual Drive Syringe Pump
    MFLX74901-87
    Log in for availability
    Each - $92.20

Product Information

  • Catalog #
    Availability
    Price
  • Pumps, Syringe Pumps RS-232 Connector Cable for 74901-80 Dual Drive Syringe Pump
    Pumps, Syringe Pumps RS-232 Connector Cable for 74901-80 Dual Drive Syringe Pump
    MFLX74901-88
    Log in for availability
    Each - $229.00