Order Entry
Puerto Rico
ContactUsLinkComponent
SevenExcellence™ Dissolved Oxygen Meters, S900, Bench, METTLER TOLEDO®
SevenExcellence™ Dissolved Oxygen Meters, S900, Bench, METTLER TOLEDO®
Supplier:  Mettler Toledo
Certificates
undefined
SevenExcellence™ Dissolved Oxygen Meters, S900, Bench, METTLER TOLEDO®
Supplier:  Mettler Toledo

Specifications

  • Catalog No:
  • 10803-066
  • 10803-060
  • 10803-064
  • 10803-062
  • Model:
  • S900
  • S600
  • S900
  • S900
  • DO Accuracy:
  • With InLab® OptiOx: ±0.1 mg/L (0 - 8); ±0.2 mg/L (8 - 20); ±10% (20 - 50)
    With InLab® 605-ISM: ±0.5%
  • With InLab® OptiOx: ±0.1 mg/L (0 - 8); ±0.2 mg/L (8 - 20); ±10% (20 - 50)
    With InLab® 605-ISM: ±0.5%
  • With InLab® OptiOx: ±0.1 mg/L (0 - 8); ±0.2 mg/L (8 - 20); ±10% (20 - 50)
    With InLab® 605-ISM: ±0.5%
  • With InLab® OptiOx: ±0.1 mg/L (0 - 8); ±0.2 mg/L (8 - 20); ±10% (20 - 50)
    With InLab® 605-ISM: ±0.5%
  • DO Concentration:
  • 0.000 - 50 mg/L (with InLab® OptiOx); 0.00 - 99 mg/L (with InLab® 605-ISM)
  • 0.000 - 50 mg/L (with InLab® OptiOx); 0.00 - 99 mg/L (with InLab® 605-ISM)
  • 0.000 - 50 mg/L (with InLab® OptiOx); 0.00 - 99 mg/L (with InLab® 605-ISM)
  • 0.000 - 50 mg/L (with InLab® OptiOx); 0.00 - 99 mg/L (with InLab® 605-ISM)
  • DO Resolution:
  • 0.001/0.01/0.1 mg/L
  • 0.001/0.01/0.1 mg/L
  • 0.001/0.01/0.1 mg/L
  • 0.001/0.01/0.1 mg/L
  • DO Saturation:
  • 0.0 - 500% (with InLab® OptiOx); 0.0 - 600% (with InLab® 605-ISM)
  • 0.0 - 500% (with InLab® OptiOx); 0.0 - 600% (with InLab® 605-ISM)
  • 0.0 - 500% (with InLab® OptiOx); 0.0 - 600% (with InLab® 605-ISM)
  • 0.0 - 500% (with InLab® OptiOx); 0.0 - 600% (with InLab® 605-ISM)
  • DO Barometric Pressure Range:
  • 7.25 - 15.95 psi
  • 7.25 - 15.95 psi
  • 7.25 - 15.95 psi
  • 7.25 - 15.95 psi
  • DO Calibration:
  • 2 points (2 pre-defined standards and 1 user-defined standard)
  • 2 points (2 pre-defined standards and 1 user-defined standard)
  • 2 points (2 pre-defined standards and 1 user-defined standard)
  • 2 points (2 pre-defined standards and 1 user-defined standard)
  • Temperature Range:
  • 0.0...+50 °C (with InLab® OptiOx); 0.0...+60 (with InLab® 605-ISM)
  • 0.0...+50 °C (with InLab® OptiOx); 0.0...+60 (with InLab® 605-ISM)
  • 0.0...+50 °C (with InLab® OptiOx); 0.0...+60 (with InLab® 605-ISM)
  • 0.0...+50 °C (with InLab® OptiOx); 0.0...+60 (with InLab® 605-ISM)
  • Temperature Resolution:
  • 0.1 °C
  • 0.1 °C
  • 0.1 °C
  • 0.1 °C
  • Temperature Accuracy:
  • ±0.1 °C
  • ±0.1 °C
  • ±0.1 °C
  • ±0.1 °C
  • Temperature Compensation:
  • Linear, non linear, off
  • Linear, non linear, off
  • Linear, non linear, off
  • Linear, non linear, off
  • Reference temperature:
  • 20 °C or 25 °C
  • 20 °C or 25 °C
  • 20 °C or 25 °C
  • 20 °C or 25 °C
  • Display:
  • Colour TFT
  • Colour TFT
  • Colour TFT
  • Colour TFT
  • Connections:
  • Optical (Mini-LTW) or polarographic (BNC)
  • Optical (Mini-LTW) or polarographic (BNC)
  • Optical (Mini-LTW) or polarographic (BNC)
  • Optical (Mini-LTW) or polarographic (BNC)
  • Outputs:
  • RS232, USB-A, USB-B, LAN
  • RS232, USB-A, USB-B, LAN
  • RS232, USB-A, USB-B, LAN
  • RS232, USB-A, USB-B, LAN
  • Power supply:
  • DC 12V - 10W
  • DC 12V - 10W
  • DC 12V - 10W
  • DC 12V - 10W
  • Data Logging Capacity:
  • At least 20 000 data points, 250 analyses
  • At least 20 000 data points, 250 analyses
  • At least 20 000 data points, 250 analyses
  • At least 20 000 data points, 250 analyses
  • W×D×H:
  • 235×188×75 mm
  • 235×188×75 mm
  • 235×188×75 mm
  • 235×188×75 mm
  • Weight:
  • 1.12 kg
  • 1.12 kg
  • 1.12 kg
  • 1.12 kg

Specifications

Related Information