Get premium performance and ultimate flexibility with this Orion™ Versa Star Pro™ Benchtop Meter with pH/LogR Module for pH, mV, ORP, and LogR temperature technology.
- Interchangeable measurement modules allow multiple users to customize four separate channels to meet specific requirements
- Onscreen measurement stability indicator lets users know exactly when measurements are ready
- Auto-Read holds a stable reading, Continuous shows changing readings, Timed logs data at specific intervals, and Single-Shot holds a reading after a preset time is reached
- Easily access, update, and switch preferred measurement settings, using ten password-protected methods per channel
- Three-year meter and module warranty
Get high accuracy, premium performance and ultimate flexibility with the Orion™ Versa Star Pro™ pH/LogR™ Benchtop Meter.
Calibration log stores ten most recent calibrations per parameter with viewable graph for multipoint pH and ISE calibrations. Ensure measurement integrity by viewing the active calibration log while taking readings. Audible alarms automatically notify users when a set offset value, high/low limit value, and calibration time interval are reached. Perform up to a six point pH calibration using automatic buffer recognition of NIST, DIN, or user-defined buffer groups with choice to manually enter custom buffer values. Calibration editing option allows individual points to be fixed without a full recalibration. Customize measurements to show calibration history and pH electrode condition or simplify to show an extra large pH reading. Non-volatile meter memory preserves data and settings, even in the event of power loss. IP54-rated housing resists dust and splashes, and can be wall-mounted if table space is limited.
Meet the most challenging applications for pH, mV, ORP, and LogR temperature. Easily view measurements on the stunning color display and customize the four meter channels with interchangeable modules. Use LogR technology to measure both pH and temperature using the glass-bulb of most pH electrodes. Log up to 2000 data point sets with time/date stamp and easily transfer calibration and data logs via USB or RS232 to a printer or computer.
To order chemicals, medical devices, or other restricted products please provide ID that includes your business name & shipping address via email [email protected] or fax 484.881.5997 referencing your VWR account number. Acceptable forms of ID are:
- • State issued document with your organization's Federal Tax ID Number
- • State issued document with your organization's Resale Tax ID Number
- • City or County issued Business License
- • State Department of Health Services License
- • Any other ID issued by the State that includes the business name & address
* ATTN: California Customers may require additional documentation as part of the CA Health & Safety Code. Products that fall under this regulation will be placed on a mandatory 21-day hold after documentation is received. Avantor will not lift restrictions for residential shipping addresses.
- Catalog No:
- 89206-402
- 89206-404
- 76076-762
- pH Range:
- -2.000 to 20.000 pH
- -2.000 to 20.000 pH
- -2.000 to 20.000 pH
- pH Resolution:
- 0.1, 0.01, 0.001 pH
- 0.1, 0.01, 0.001 pH
- 0.1, 0.01, 0.001 pH
- pH Accuracy:
- ±0.002 pH
- ±0.002 pH
- ±0.002 pH
- mV range:
- ±2000.0 mV
- ±2000.0 mV
- ±2000.0 mV
- mV resolution:
- 0.1 mV
- 0.1 mV
- 0.1 mV
- mV accuracy:
- ±0.2 mV or ±0.05% of reading whichever is greater
- ±0.2 mV or ±0.05% of reading whichever is greater
- ±0.2 mV or ±0.05% of reading whichever is greater
- Temperature Resolution:
- 0.1°C, 0.1°F
- 0.1°C, 0.1°F
- 0.1°C, 0.1°F
- Temperature Accuracy:
- ±0.1°C
- ±0.1°C
- ±0.1°C
- Display:
- Color graphic LCD with user-customizable options
- Color graphic LCD with user-customizable options
- Color graphic LCD with user-customizable options
- Power supply:
- Universal AC adapter (included)
- Universal AC adapter (included)
- Universal AC adapter (included)
- Operating Temperature Range:
- 5…45 °C (41…113 °F)
- 5…45 °C (41…113 °F)
- 5…45 °C (41…113 °F)
- Data Logging Capacity:
- 2000 with time/date stamp
- 2000 with time/date stamp
- 2000 with time/date stamp
- Memory:
- Non-volatile memory preserves data log, calibration log and meter settings
- Non-volatile memory preserves data log, calibration log and meter settings
- Non-volatile memory preserves data log, calibration log and meter settings
- Languages:
- English, Spanish, French, Italian, German, Chinese, Portuguese, and Korean
- English, Spanish, French, Italian, German, Chinese, Portuguese, and Korean
- English, Spanish, French, Italian, German, Chinese, Portuguese, and Korean
- IP Rating:
- IP-54
- IP-54
- IP-54
- Dimensions:
- 28L x 24W x 10H cm (11 x 9.5 x 3.9"), modules add ≤ 2cm (0.8") L & H
- 28L x 24W x 10H cm (11 x 9.5 x 3.9"), modules add ≤ 2cm (0.8") L & H
- 28L x 24W x 10H cm (11 x 9.5 x 3.9"), modules add ≤ 2cm (0.8") L & H
- Outputs:
- USB (2), RS232
- USB (2), RS232
- USB (2), RS232
- Input:
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 2 stirrer inputs (stirrer probe)
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 2 stirrer inputs (stirrer probe)
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 2 stirrer inputs (stirrer probe)
- Alarm:
- Set point alarm, high/low limit alarm, calibration due alarm
- Set point alarm, high/low limit alarm, calibration due alarm
- Set point alarm, high/low limit alarm, calibration due alarm
- No. of Channels:
- 4 - Customizable with modules
- 4 - Customizable with modules
- 4 - Customizable with modules
- Calibration:
- pH with calibration editing option, relative mV (RmV), ORP, LogR temperature and temperature
- pH with calibration editing option, relative mV (RmV), ORP, LogR temperature and temperature
- pH with calibration editing option, relative mV (RmV), ORP, LogR temperature and temperature
- Calibration Points:
- 1 point relative mV (RmV) mode; 1 point ORP mode; 1 to 6 pH mode
- 1 point relative mV (RmV) mode; 1 point ORP mode; 1 to 6 pH mode
- 1 point relative mV (RmV) mode; 1 point ORP mode; 1 to 6 pH mode
- Weight:
- 1.2kg (2.5lbs.), modules add 0.2kg (0.5lb.) each
- 1.2kg (2.5lbs.), modules add 0.2kg (0.5lb.) each