33 results for Transfer Membranes

 

Transfer Membranes

Highly sensitive transfer membranes use capillary action methods to separate DNA, RNA, or protein fragments for detection. Working well with the gels and buffers required for transfer and immobilization steps, the transfer membranes are durable enough to be subjected to multiple stripping, reprobing, hybridization cycles. The high-binding discs, sheets, and rolls come in various pore sizes and charges to fit any blotting techniques in molecular biology and genetic research.

Sort By
Biodyne® Nylon Transfer Membranes, Cytiva (Formerly Pall Lab)

Biodyne® Nylon Transfer Membranes, Cytiva (Formerly Pall Lab)

Supplier: Cytiva

Biodyne® Transfer Membranes offer high sensitivity and low background for enhanced detection and resolution. They are ideal for nucleic acid detection.

Expand 11 Items
 
FluoroTrans® PVDF Transfer Membranes, Cytiva (Formerly Pall Lab)

FluoroTrans® PVDF Transfer Membranes, Cytiva (Formerly Pall Lab)

Supplier: Cytiva

Naturally hydrophobic PVDF, ideal for a wide variety of protein-analysis applications. The family of FluroTrans® media are white, microporous solid phase supports that bind proteins tenaciously via hydrophobic interactions. FluoroTrans® membrane is optimised for N-terminal protein sequencing. FluoroTrans® W membranes are optimised for Western transfer applications. They allow for sensitive protein detection with low background and very low protein burn-through. Immobilised proteins can be visually detected with Coomassie® Blue, Amido black, Ponceau S, and colloidal gold.

Expand 8 Items
 
Pre-Cut Western Blotting Membranes, Azure Biosystems

Pre-Cut Western Blotting Membranes, Azure Biosystems

Supplier: Azure Biosystems

Azure offers pre-cut PVDF and nitrocellulose membranes for Western blotting applications.

Expand 5 Items
 
Amersham™ Hybond™ LFP Western Blotting Membrane, 0.2 PVDF, Cytiva

Amersham™ Hybond™ LFP Western Blotting Membrane, 0.2 PVDF, Cytiva

Supplier: Cytiva

Amersham Hybond LFP 0.2 PVDF is a low-fluorescent, hydrophobic membrane, with 0.2 µm pore size, for protein transfer. Amersham Hybond LFP is optimized for fluorescent detection in Western blotting applications and for use with the Amersham ECL Plex detection system.

Expand 4 Items
 
Amersham™ Protran® Western Blotting Membranes, Nitrocellulose, Cytiva

Amersham™ Protran® Western Blotting Membranes, Nitrocellulose, Cytiva

Supplier: Cytiva

Amersham™ Protran® membranes are manufactured from 100% pure nitrocellulose to ensure the highest binding capacity possible. They are compatible with a variety of detection methods, including isotopic, chemiluminescent, colorimetric and fluorescent. No methanol pre-wetting step is required, making this the membrane of choice for proteins which prefer aqueous environments. Prior to transfer the membrane is simply wetted with water, and then placed in the transfer buffer. No other pretreatment steps are necessary.

Expand 26 Items
 
Amersham™ Hybond™ P Western Blotting Membrane, 0.45 PVDF, Cytiva

Amersham™ Hybond™ P Western Blotting Membrane, 0.45 PVDF, Cytiva

Supplier: Cytiva

Amersham Hybond P 0.45 PVDF is a 0.45 μm pore size hydrophobic membrane, with high physical strength, highly suitable for stripping and reprobing. Membranes provide excellent performance in fluorescent and chemiluminescent applications.

Expand 8 Items
 
Amersham™ Protran® Premium Western Blotting Membranes, Nitrocellulose, Cytiva

Amersham™ Protran® Premium Western Blotting Membranes, Nitrocellulose, Cytiva

Supplier: Cytiva

Amersham™ Protran® Premium nitrocellulose blotting membranes provide excellent sensitivity, resolution and low background in fluorescence Western blotting detection applications.

Expand 15 Items
 
Amersham™ Hybond™ P Western Blotting Membrane, 0.2 PVDF, Cytiva

Amersham™ Hybond™ P Western Blotting Membrane, 0.2 PVDF, Cytiva

Supplier: Cytiva

Amersham Hybond P 0.2 PVDF is a 0.2 μm pore size hydrophobic membrane with high physical strength. This results in significant handling advantages over unsupported nitrocellulose and makes the membrane highly suitable for stripping and reprobing. The small pore size of the membrane minimizes ‘blow-through’ and increases protein binding over a wide range of molecular weights. Ideal for use with standard colorimetric and chemiluminescent detection methods for proteins of

Expand 4 Items
 
Amersham™ Protran® Supported Nitrocellulose Western Blotting Membranes, Cytiva

Amersham™ Protran® Supported Nitrocellulose Western Blotting Membranes, Cytiva

Supplier: Cytiva

Amersham™ Protran® Supported is a robust protein blotting membrane, with 0,2 µm pore size, made of reinforced nitrocellulose for multiple reprobings.

Expand 11 Items
 
Amersham™ Hybond™ SEQ Western Blotting Membrane, 0.2 PVDF, Cytiva

Amersham™ Hybond™ SEQ Western Blotting Membrane, 0.2 PVDF, Cytiva

Supplier: Cytiva

0.2 µm pore size for higher surface area, resulting in better binding of low molecular weight proteins. Amersham Hybond SEQ 0.2 PVDF is a 0.2 µm pore size hydrophobic membrane designed specifically for protein sequencing applications. The small pore size of this membrane minimizes ‘blow-through’ and increases protein binding over a wide range of molecular weights.

Expand 1 Items
 
Blotting Membranes, Amersham Hybond™ ECL™, Cytiva

Blotting Membranes, Amersham Hybond™ ECL™, Cytiva

Supplier: Cytiva

Hybond™ ECL™ gives excellent sensitivity, resolution, and low background for all labelling and detection systems (radioactive, non radioactive, and chromogenic), especially when used with ECL™, ECL™ Prime, and ECL™ Plex Western Blotting Detection kits and reagents. Special packaging features include interleaf on both sides of the membrane and air-tight resealable aluminium bag with label space for marking the 'opened on' date.

Expand 2 Items
 
Owl™ Immobilon™-P Transfer Membranes, PVDF, Thermo Scientific

Owl™ Immobilon™-P Transfer Membranes, PVDF, Thermo Scientific

Supplier: Thermo Fisher Scientific

Hydrophobic polyvinylidene fluoride transfer membrane has a high signal-to-noise ratio, which allows for the use of mild blocking procedures

Expand 3 Items
 
Whatman™ Protran® BA85 & BA83 NC Western Blotting Membranes, Nitrocellulose, Cytiva

Whatman™ Protran® BA85 & BA83 NC Western Blotting Membranes, Nitrocellulose, Cytiva

Supplier: Cytiva

Protran® membranes are manufactured from 100% pure nitrocellulose to ensure the highest binding capacity possible. They are compatible with a variety of detection methods, including isotopic, chemiluminescent, colorimetric and fluorescent. No methanol pre-wetting step is required, making this the membrane of choice for proteins which prefer aqueous environments. Prior to transfer the membrane is simply wetted with water, and then placed in the transfer buffer. No other pre treatment steps are necessary.

Expand 6 Items
 
Whatman™ Nytran N Blotting Membranes, Whatman products (Cytiva)

Whatman™ Nytran N Blotting Membranes, Whatman products (Cytiva)

Supplier: Cytiva

Whatman Nytran nylon membranes are available in two formats: Nytran N is moderately charged and Nytran SuPerCharge (SPC) has a very high positive charge.

Expand 2 Items
 
Whatman™ Nytran SuPerCharge (SPC) Blotting Membranes, Whatman products (Cytiva)

Whatman™ Nytran SuPerCharge (SPC) Blotting Membranes, Whatman products (Cytiva)

Supplier: Cytiva

Nytran® SuPerCharge (SPC) nylon membranes have a very high positive charge and a higher density of nylon per unit area. Available as circles, sheets or rolls for microplates.

Expand 3 Items
 

PVDF Pure Transfer Membranes, GVS Filter Technology

Supplier: GVS FILTER TECHNOLOGY

PVDF transfer membranes.

Expand 5 Items
 
MagnaNeutral™ Transfer Membrane, GVS

MagnaNeutral™ Transfer Membrane, GVS

Supplier: GVS FILTER TECHNOLOGY

Neutral nylon transfer membrane.

Expand 3 Items
 

Transfer Membranes, NuSep

Supplier: NuSep

Transfer membranes are 7x8.5cm (23/4x35/16").

Expand 4 Items
 
NitroPure Transfer Membranes, GVS Filter Technology

NitroPure Transfer Membranes, GVS Filter Technology

Supplier: GVS FILTER TECHNOLOGY

Nitrocellulose membranes.

Expand 12 Items
 
NitroPlus Transfer Membranes, GVS Filter Technology

NitroPlus Transfer Membranes, GVS Filter Technology

Supplier: GVS FILTER TECHNOLOGY

Supported Nitrocellulose (MCE) membranes.

Expand 14 Items
 
Advansta Transfer Membranes

Advansta Transfer Membranes

Supplier: Advansta

Convenient pre-cut nitrocellulose and PVDF membranes for Western blotting. Advansta offers convenient pre-cut membranes for Western blotting, sized for protein minigels and available in both nitrocellulose and PVDF. Save time and avoid concerns about membrane contamination from dirty scissors by using quality-controlled, pre-cut membranes. 10 Sheets.

Expand 5 Items
 
Pierce™ Transfer Membranes, PVDF, Thermo Scientific

Pierce™ Transfer Membranes, PVDF, Thermo Scientific

Supplier: Invitrogen

Hydrophobic transfer membranes made of high quality PVDF, which provides high binding capacity for proteins and nucleic acids.

Expand 4 Items
 

Transfer Membranes, Advansta

Supplier: ADVANSTA INC MS

Nitrocellulose and PVDF membranes for Western blotting.

Expand 9 Items
 
Biodyne™ A Nylon Membrane, 0.45 µm, Thermo Scientific

Biodyne™ A Nylon Membrane, 0.45 µm, Thermo Scientific

Supplier: Invitrogen

Thermo Scientific Biodyne A Nylon Membranes are sheets of unmodified nylon that provide excellent binding characteristics for nucleic acid transfer, blotting and detection methods.

Expand 1 Items
 
Nitrocellulose Membrane, 0.2 µm, Bio-Rad

Nitrocellulose Membrane, 0.2 µm, Bio-Rad

Supplier: Bio-Rad

Bio-Rad 0.2 µm pure nitrocellulose membrane is recommended for blotting nucleic acids <550 bp and low molecular weight proteins. The 0.2 µm pore size minimizes protein sample loss due to transfer through the membrane. For larger target proteins and nucleic acids, Bio-Rad 0.45 µm nitrocellulose is recommended.

Expand 8 Items
 

Biodyne™ B Nylon Membrane, 0.45 µm, Thermo Scientific

Supplier: Invitrogen

Thermo Scientific Biodyne B Nylon Membranes are sheets of positively charged nylon that provide excellent binding characteristics for nucleic acid transfer, blotting and detection methods.

Expand 1 Items
 
Sequi-Blot™ PVDF Membrane, Bio-Rad

Sequi-Blot™ PVDF Membrane, Bio-Rad

Supplier: Bio-Rad

Sequi-Blot™ PVDF membrane is ideal for protein sequencing: It retains target protein very strongly during protein transfer and provides the binding capacity to sequence even low-abundance samples.

Expand 1 Items
 

Nitrocellulose Membrane, 0.45 µm, Bio-Rad

Supplier: Bio-Rad

Bio-Rad 0.45 µm pure nitrocellulose membrane is recommended for analytical blotting, including western blotting, dot/slot blot screening, northern blotting, and Southern blotting

Expand 10 Items
 

Immun-Blot® PVDF Membrane, Bio-Rad

Supplier: Bio-Rad

Immun-Blot PVDF Membrane is engineered for western blots with chemiluminescent and colorimetric detection

Expand 6 Items
 

Immun-Blot® Low Fluorescence PVDF Membrane, Bio-Rad

Supplier: Bio-Rad

Immun-Blot® Low Fluorescence PVDF Membrane has the same properties as standard PVDF membranes coupled with minimal autofluorescence.

Expand 5 Items
 