Multi-Element Standards
Avantor offers a wide range of certified cationic standards designed for instrument calibration in ion-exchange chromatography (IC) applications, which can be applied toward environmental or food analysis and quality control. IC is an analytical technique used for the separation and quantification of anions and cations in aqueous samples. Avantor offers high-purity, well-defined reference materials ideal for low-ppm level quantification or trace analysis. Bottles of cationic standards are available for a range of elements.
Multi-Element Organometallic Oil Standards, 5 Elements, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
SPEX CertiPrep presents a comprehensive offering of Organometallic Oil Standards. The applications of these standards include:
Expand 5 Items
26 Element ICP Calibration/Quality Control Standards
Supplier: Inorganic Ventures
Quality Control Standard 26 is a certified reference material set in a nitric acid/hydrofluoric acid matrix for stability.
Expand 5 Items
Assurance® Grade Mixed Calibration Standard 4A with Mercury and without Mercury for AA and ICP, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Assurance® mixed multi-element standards for AA & ICP.
Expand 4 Items
Claritas PPT® Grade ICP-MS Instrument Check Standard 1, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® multi-element standards for ICP-MS
Expand 1 Items
Assurance® Grade LFS Solution 2 for AA and ICP, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Laboratory fortifying stock (LFS) solutions. Assurance® mixed multi-element standards for AA & ICP.
Expand 1 Items
Assurance® Grade Primary Drinking Water Metals with and without Mercury for AA & ICP, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Assurance® Grade multi-element drinking water pollutant standards for AA & ICP.
Expand 4 Items
USP 232 Revision 40, Oral 3 Mix 1 Elemental Impurities, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
USP Standard.
Expand 1 Items
Claritas PPT® Grade ICP-MS Tuning Solutions, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Claritas PPT® Multi-Element Standards for ICP-MS. Tuning solutions are for ICP-MS instrumentation tuning and mass calibration prior to analysis.
Expand 4 Items
TOC/KHP Standards, 1000 µg/ml
Supplier: Inorganic Ventures
TOC/KHP Standards, 1000 µg/ml
Expand 2 Items
EPA Method 200.8 Calibration Standard 1
Supplier: Inorganic Ventures
EPA Method 200.8 Calibration Standard 1
Expand 1 Items
Assurance® Grade Calibration Standards without Mercury for AA & ICP, SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
Assurance® mixed multi-element standards for AA & ICP.
Expand 1 Items
ICP-MS Interferents B3 without Mercury, 2 µg/ml (2 ppm), SPEX CertiPrep
Supplier: SPEX CERTIPREP LLC
CLP Standards for ICP & ICP-MS
Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.
The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.
US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:
• Exhibit C, Inorganic Target Analyte List (TAL)
• Exhibit D, Analytical Methods
• Exhibit E, QA/QC Requirements
CLP ISM 01.2 and ILM 05.2 & 05.3 Standards for ICP-MS
For verification of inter-element and background correction factors at the beginning and the end of each analysis run. In addition, a verification must be done after every 20th sample. Two solutions are required for the most common interference check: Solution A, the interferents alone (CL-INT-A2) and Solution AB, a combination of interferents (CL-INT-A2) and analytes (CL-INT-B3 or CL-INT-B4). Solution A is prepared by diluting CL-INT-A2 10-fold. Solution AB is prepared by diluting CL-INT-A2 10-fold and CL-INT-B3 or CL- INT-B4 100-fold; for example, 10 ml of CL-INT-A2 and 1 ml of CL-INT-B3 or CL-INT-B4 into a 100 ml volumetric flask, brought to volume with a matrix blank. Once prepared, the solutions should be analyzed consecutively, starting with Solution A.
Expand 1 Items
1 ppb 15 Element ICP-MS Calibration/Tuning Standard
Supplier: Inorganic Ventures
1 ppb 15 Element ICP-MS Calibration/Tuning Standard
Expand 1 Items
Calibration Solution #3
Supplier: Inorganic Ventures
Calibration Solution #3
Expand 1 Items
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".
Otherwise, you will receive generic recommendations.



