Order Entry
Poland
ContactUsLinkComponent
 

12301 Results for: "PerkinElmer"

SPE columns, Supra-Poly® XWP

Supplier: PerkinElmer

SPE Supra-Poly® extreme capacity wide pore (XWP) are polymer based columns, polystyrene-divinylbenzene (PSDVB). Ideal for extracting polar and non-polar compounds when analysing drugs and drug metabolites in biological fluids.

Expand 8 Items
Loading...

Capillary columns, Elite-M for autosystem

Supplier: PerkinElmer

Column type: GC column, Elite-M1, Ø int.: 0,53 mm, Length: 30 m, Film thickness: 1,50 µm

Expand 32 Items
Loading...

Capillary columns, Elite-SimDist for autosystem

Supplier: PerkinElmer

Elite-SimDist Dimethylpolysiloxane capillary columns processed for simulated distillation.

Expand 2 Items
Loading...

Capillary columns, Elite-WAX for autosystem

Supplier: PerkinElmer

Elite-WAX Polyethylene Glycol capillary columns are ideal for the analysis of polar compounds.

Expand 24 Items
Loading...

Capillary columns, Elite-1ht for autosystem

Supplier: PerkinElmer

The Elite-1ht columns are 100% dimethyl polysiloxane and come in a variety of sizes.

Expand 3 Items
Loading...

Replacement parts for GC packed injectors

Supplier: PerkinElmer

Liner, quartz, For: GC packed injectors

Expand 5 Items
Loading...

Capillary columns, Elite-17 for autosystem

Supplier: PerkinElmer

Elite-17 (50% Phenyl) Methylpolysiloxane series capillary columns are ideal for confirmation analysis and are inert for active compounds.

Expand 16 Items
Loading...

Capillary columns, Elite-TPH for autosystem

Supplier: PerkinElmer

Elite-TPH specialty phase capillary columns are ideal for the analysis of total petroleum hydrocarbons.

Expand 2 Items
Loading...

Photoionisation detector with PPC add-on kit

Supplier: PerkinElmer

Photoionisation detector with programmable pneumatic control (PPC) add-on kit for gas chromatography.

Expand 1 Items
Loading...

Headspace screw top vials

Supplier: PerkinElmer

Chromatography vial, Headspace screw neck, 22,00 ml, Glass, Clear, Ø×H: 23×75,5 mm, Rounded bottom (HS bottom), Non sterile, Cap included: No

Expand 3 Items
Loading...

Paper, Alsiflex

Supplier: PerkinElmer

Alsiflex paper for TGA6, Pyris6 TGA, TGA4000, and STA6000 istruments.

Expand 1 Items
Loading...

Screw caps for autosampler waste and wash vials

Supplier: PerkinElmer

Chromatography vial closure, PTFE/silicone, Ø: 13 mm, Screw cap, 1000 per pack, Septum: PTFE/silicone (Ultra Low Bleed)

Expand 3 Items
Loading...

Petri dishes, glass

Supplier: PerkinElmer

Soda-lime glass. Suitable for the NIRA II spinner.

Expand 2 Items
Loading...

Diffuser caps for waste and wash vials

Supplier: PerkinElmer

The conical shape allows the needle to penetrate in to solvent or waste.

Expand 1 Items
Loading...

Germanium standard solution, 1,000 mg/L Ge in water (from (NH4)2GeF6) standard for AAS and ICP

Supplier: PerkinElmer

Germanium Standard, 1000 mg/L, Germanium, Matrix: H₂O/0,16% F-, Application: ICP standards

Expand 1 Items
Loading...

Sample pans for Pyris 1 TGA and TGA 8000

Supplier: PerkinElmer

Ceramic, Ceramic sample pans, pack of 10

Expand 1 Items
Loading...

Neodymium standard solution, 1000 mg/L Nd in dil. nitric acid (from Nd₂O₃) standard for AAS and ICP

Supplier: PerkinElmer

Neodymium Standard, 1000 mg/L, Neodymium, Matrix: 2% HNO₃, Application: ICP standards

Expand 1 Items
Loading...

Lithium standard solution, 1000 mg/L Li in dil. nitric acid (from Li₂CO₃) standard for AAS and ICP

Supplier: PerkinElmer

Lithium Standard, 1000 mg/L, Lithium, Matrix: 2% HNO₃, Application: ICP standards

Expand 1 Items
Loading...

Gadolinium standard solution, 1,000 mg/L Gd in dilute nitric acid (de Gd2O3) standard for AAS and ICP

Supplier: PerkinElmer

Gadolinium Standard, 1000 mg/L, Gadolinium, Matrix: 2% HNO₃, Application: ICP standards

Expand 1 Items
Loading...

Hollow cathode lamps, Atomax™

Supplier: PerkinElmer

Hollow cathode lamp, Atomax™, For: Non Perkin-Elmer instruments, Lutetium

Expand 65 Items
Loading...

Combustion calibration standard

Supplier: PerkinElmer

Combustion calibration statndard for sulphur analysis, cystine (26,69% S), solid 4 g

Expand 1 Items
Loading...

Samarium standard solution, 1,000 mg/L Sm in dil. nitric acid (from Sm2O3) standard for AAS and ICP

Supplier: PerkinElmer

Samarium Standard, 1000 mg/L, Samarium, Matrix: 2% HNO₃, Application: ICP standards

Expand 1 Items
Loading...

Vanadium standard solution, 1000 mg/L V in dil. nitric acid (from V) standard for AAS and ICP

Supplier: PerkinElmer

Vanadium Standard, 1000 mg/L, Vanadium, Matrix: 2% HNO₃, Application: ICP standards

Expand 1 Items
Loading...

Portable gas leak detector

Supplier: PerkinElmer

Designed for use with gas chromatography (GC) systems, it detects minute leaks of any gas with a thermal conductivity different from air.

Expand 1 Items
Loading...

Calibration standard, single element, strontium for AAS and ICP-OES, pure grade

Supplier: PerkinElmer

Until 10th October 2017 it is still allowed to use mercury thermometers if they are exclusively intended to be used for tests as per standards which require the usage of mercury thermometers.

Expand 1 Items
Loading...

Calibration standard, single element, tungsten for AAS and ICP-OES, pure grade

Supplier: PerkinElmer

Until 10th October 2017 it is still allowed to use mercury thermometers if they are exclusively intended to be used for tests as per standards which require the usage of mercury thermometers.

Expand 1 Items
Loading...

Tin standard solution, for ICP-MS, Pure Plus grade

Supplier: PerkinElmer

Single element standard is supplied with a comprehensive Certificate of Analysis that documents the quality and reliability.

Expand 1 Items
Loading...

Sample pans for autosamplers, Diamond™ DSC

Supplier: PerkinElmer

Sample pans without covers, aluminium, 50 µl, sealed

Expand 14 Items
Loading...

Supplies for autosamplers, Cetac

Supplier: PerkinElmer

Cetac drain pump tubing kit

Expand 2 Items
Loading...

MPLC cartridge columns, Brownlee™

Supplier: PerkinElmer

The MPLC cartridge system allows direct coupling of an analytical and NewGuard™ cartridge without introduction of any dead volume. A specific cartridge holder (30, 100, 220 mm) is required for each cartridge length.

Expand 40 Items
Loading...
Recommended for You