Order Entry
Poland
Orders LinkContactUsLinkComponent
 

"Ion Exchange Column"

 
 
Anion exchange chromatography columns, HiTrap™ Capto™ Q ImpRes

Anion exchange chromatography columns, HiTrap™ Capto™ Q ImpRes

Supplier: Cytiva

HiTrap™ Capto™ Q ImpRes is a strong anion exchanger prepacked with BioProcess Capto™ ImpRes media for screening and small-scale protein purifications using ion exchange chromatography (IEX).

Expand 3 Items
 
HiPrep Q FF Columns, Cytiva

HiPrep Q FF Columns, Cytiva

Supplier: Cytiva

HiPrep Q FF is a strong anion exchanger prepacked with Q Sepharose Fast Flow, ready-to-use for fast, preparative separations of proteins and other biomolecules using ion exchange (IEX) chromatography.

Expand 1 Items
 

Solid phase extraction cartridges, Bond Elut™ SAX

Supplier: VARIAN

Bond Elut™ SAX is a strong anion exchange sorbent ideally suited for the extraction of compounds such as carboxylic acids, which may not retain effectively on weak anion exchange sorbents. The sorbent is supplied in the chloride counter ion form. You can modify the selectivity of the phase by replacing the chloride ion with other anions, such as acetate and hydroxide.

Expand 29 Items
 
HiPrep DEAE FF Columns, Cytiva

HiPrep DEAE FF Columns, Cytiva

Supplier: Cytiva

HiPrep DEAE FF 16/10 is a weak anion exchanger prepacked with DEAE Sepharose Fast Flow, ready-to-use for fast, preparative separations of proteins and other biomolecules using ion exchange (IEX) chromatography.

Expand 1 Items
 

Sample loops for Rheodyne® valves

Supplier: VICI JOUR RESEARCH

These PEEK sample loops contain no metals or other extractable compounds. Therefore, no foreign materials will be introduced into the system. Softener free PE caps are used to avoid the contamination of the tubing. Particularly suited for separations involving proteins, peptides, nucleic acids or other samples of biological origin as well as in IC systems where metal traces may interact with ionic samples or release transition metals that may deactivate ion exchange columns.

Expand 1 Items
 
Cation exchange chromatography columns, HiTrap™ SP XL

Cation exchange chromatography columns, HiTrap™ SP XL

Supplier: Cytiva

HiTrap SP XL are strong cation exchangers prepacked with SP Sepharose XL media, optimized for fast, convenient small-scale protein capture using ion exchange (IEX) chromatography.

Expand 2 Items
 
Selection kit, HiTrap™ IEX

Selection kit, HiTrap™ IEX

Supplier: Cytiva

HiTrap IEX Selection Kit is used for screening of the optimal Cytiva ion exchange resin for specific application and development work.

Expand 1 Items
 
Multimode columns, HiTrap™ Capto™ adhere

Multimode columns, HiTrap™ Capto™ adhere

Supplier: Cytiva

HiTrap Capto adhere is prepacked with Capto adhere, a multimodal BioProcess ion exchange resin designed to remove contaminats in post-protein A purification.

Expand 3 Items
 

Solid phase extraction cartridges, Bond Elut™ CBA

Supplier: VARIAN

CBA is a mid-polarity sorbent and weak cation exchanger (pKa 4,8). It can be used with a wider range of counter-ions than lower pKa sorbents like SCX and will demonstrate easier elution of quaternary amine functionalised analytes.

Expand 8 Items
 

Solid phase extraction cartridges, Bond Elut™ SCX

Supplier: VARIAN

Bond Elut™ SCX is a strong cation exchanger with a very low pKa. Although the pKa is similar to Bond Elut™ PRS, the presence of the benzene ring in the functional group increases the potential for non-polar interactions. This non-polar characteristic becomes particularly important when conducting ion-exchange from aqueous systems, where selectivity towards compounds exhibiting cationic and non-polar character is seen.

Expand 24 Items
 

SampliQ SPE cartridges

Supplier: Agilent

High quality SampliQ SPE (Solid Phase Extraction) products help the user confidently extract and concentrate samples from complex matrices, ensuring fast, accurate, and reproducible results from the very first step. The SampliQ line includes polymers, silica and non-silica options to meet user's specific SPE needs.

Expand 1 Items
 

Ion exchange resins, Diaion® HP20

Supplier: Thermo Fisher Scientific

Diaion® HP20 is used as a filler in chromatography columns due to its extremely large pores. It is considered as an effective adsorbent to eliminate toxic effects in fermentation and separation of traces heavy metal ions. It is also useful for the purification of peptides, proteins, fermentation products, polyphenols and cephalosporin C. It helps to remove bitter tasting substances from fruit juices.

Expand 1 Items
 
Avantor® Allsep Anion, Anion Exchange HPLC Columns

Avantor® Allsep Anion, Anion Exchange HPLC Columns

Supplier: Avantor

Allsep anion is a methacrylate based phase with quaternary ammonium functional groups, optimised for use with both suppressed and non-suppressed conductivity detection. They are recommended for applications involving inorganic anions, weak and strong acid ions, metal complexes and organic acids.

    
Expand 9 Items
 
Solid phase extraction cartridges, Bond Elut™ C18

Solid phase extraction cartridges, Bond Elut™ C18

Supplier: VARIAN

Bond Elut™ C18 is the most hydrophobic, bonded silica sorbent in the Bond Elut™ range. It is the most popular SPE sorbent because of its extremely retentive nature for non-polar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices. When analysing small to intermediate molecules, Bond Elut™ C18 can be used for desalting aqueous matrices prior to ion exchange, as salts pass through the sorbent unretained.

Expand 43 Items
 
Amberlite® IRA-410 (Cl) ion-exchange resin, Supelco®

Amberlite® IRA-410 (Cl) ion-exchange resin, Supelco®

Supplier: Merck

Amberlite® IRA-410 was used as packing material for columns. Amberlite® IRA-410 was also used in urinary analysis by HPLC.

Expand 1 Items
 
Anion exchange HPLC columns, PRP-X100

Anion exchange HPLC columns, PRP-X100

Supplier: HAMILTON BONADUZ

The PRP-X100 is a polymeric column packing for separation of inorganic and organic anions from 10 to 500 ppm. These columns can be used to separate ions at concentrations from 1 to 1000 ppm without suppression or elaborate preconcentration techniques. The highly inert polymeric support resists chemical attack from organic solvents and aqueous buffers (0 - 100% aqueous or organic; pH 1 to 13), effectively lengthening column life.

Expand 26 Items