You searched for: Chromatography Standards
Frequently used for calibration, the chromatography standards have a known concentration to test separating equipment for performance faults. Analytical equipment error would impact the dependability of retention time, purity, molecular weight, and compound identification conclusions. Improving data quality, the substances allow personnel to plot analyte signal ratios and obtain concentrations from a calibration curve. Chromatography standards verify instruments are suitable for intended ion exchange, gel filtration, and hydrophobic interaction procedures.
Polystyrene Test Film - MIR
Supplier: PerkinElmer
This test film is an easy-to-use standard to check frequency, accuracy and any changes.
Expand 1 Items
Calibration reference materials for autosamplers, Diamond™ DSC
Supplier: PerkinElmer
DSC Standard, Reference material, Perkalloy, Diamond™
Expand 8 Items
Standards for liquid chromatography
Supplier: Agilent
Standard for Liqid Chromatography, OQ/PV sample for dissolution test, 150 mg/l, caffeine in water, 500 ml
Expand 2 Items
Standards for gas chromatography, OQ/PV headspace sample standard
Supplier: Agilent
OQ/PV headspace sample standard contains 0,2 to 0,3% t-butyl disulphide, 1,2-dichlorobenzene, and nitrobenzene in ethanol.
Expand 1 Items
Size exclusion chromatography protein standards, AdvanceBio SEC
Supplier: Agilent
Size Exclusion Standard, AdvanceBio SEC 300Å Protein Standard, lyophilized, 1.5 mL
Expand 2 Items
Pre-prepared polystyrene kits, EasiCal™
Supplier: VARIAN
The EasiCal system for organic solvents consists of two different combs, each with ten detachable spatulas supporting a mixture of five polymer standards with MWs selected to provide equidistant calibration points for greater accuracy.
Expand 4 Items
Polyethylene glycol/oxide standards
Supplier: VARIAN
These hydrophilic polymers are suitable for both aqueous SEC and organic GPC using the majority of polar organic solvents. The two types are chemically similar that can be used together across a wider molecular weight range with aqueous and organic polymers.
Expand 58 Items
HPLC standards, LiChroTest®, Supelco®
Supplier: Merck
Standard samples for HPLC System Qualification.
Expand 6 Items
Reference substances for GC analysis, Supelco®
Supplier: Merck
Reference substances can be used for the identification of unknown compounds in a gas chromatogram or as standards in quantitative GC analysis. They serve also for the characterisation of GC column properties.
Expand 3 Items
Polystyrene standards, GPC/SEC columns calibration
Supplier: VARIAN
Polystyrene standards for many organic solvents either for conventional GPC column calibration or for calibrating light scattering and viscosity detectors that provide equidistant calibration points for greater accuracy.
Expand 67 Items
Polymethylmethacrylate standards, GPC/SEC columns calibration
Supplier: VARIAN
Polymethylmethacrylate (PMMA) standards are extremely versatile as they can be used for organic GPC with a wide range of medium polarity eluents, such as tetrahydrofuran, toluene, methyl ethyl ketone and ethyl acetate.
Expand 43 Items
Pre-weighted calibration kits, EasiVial™
Supplier: VARIAN
The quickest and most convenient method to deliver an accurate 12 point column calibration for organic and aqueous GPC/SEC column calibration.
Expand 18 Items
Polystyrene film - IR transmission wavelength standards, NIST-1921B
Supplier: LGC Standards PROMOCHEM
NIST-1921B, Polystyrene film - IR transmission wavelength
Expand 1 Items
Reversed phase test mix 2, certified reference material, Supelco®
Supplier: Merck
HPLC Standard, Reversed Phase Test Mix 2, TraceCERT®, Supelco®, in acetonitrile: water (varied conc.) solution, Certified reference material, Pk Info: ampule of 1 mL
Expand 1 Items
Polystyrene standard ReadyCal set Mp 400-2000000, analytical standards for GPC
Supplier: Merck
Set contains 12 different polystyrene standards with Mp ~374, ~1620, ~3420, ~9130, ~18100, ~32500, ~67500, ~128000, ~246000, ~659000, ~1000000, ~2180000; always 4 standards are lyophilised in a 1,5 ml vial (green, red or white); for 1 complete calibration use one of each of the green, red and white vials; 1 set contains 30 vials for 10 complete calibrations.
Expand 1 Items
Polyethylene glycol Standard ReadyCal Set Mp 200-1200000, for GPC, Supelco
Supplier: Merck
Set contains 10 different polyethylene glycol/polyethylene oxide standards with Mp ~194, ~970, ~2010, ~4450, ~15000, ~22100, ~62000, ~217000, ~490000, ~1190000; always 3 or 4 standards are lyophilised in a 1,5 ml vial (black, blue or yellow); for 1 complete calibration use one of each of the black, blue and yellow vials; 1 set contains 30 vials for 10 complete calibrations.
Expand 1 Items
Polystyrene, average Mw 290000 (typical), average Mn 130000 (typical), analytical standard, Supelco®
Supplier: Merck
GPC Standard, Polystyrene, average Mw 290000 (typical), average Mn 130000 (typical), Supelco®, Analytical standard
Expand 1 Items
Poly(vinyl chloride), average Mw 85000 (Typical), average Mn 40000 (Typical), analytical standard, Supelco®
Supplier: Merck
GPC Standard, Poly(vinyl chloride), average Mw 85000 (Typical), average Mn 40000 (Typical), Supelco®, Analytical standard
Expand 1 Items
Poly(methyl methacrylate) PMMA, analytical standard, for GPC
Supplier: Merck
Poly(methyl methacrylate) is a rigid and transparent type of polymer material. It is obtained via polymerization of methyl methacrylate monomer.
Expand 10 Items
Polyethylene glycol Standard ReadyCal Set Mp 102-40′000, for GPC
Supplier: Merck
Set contains 12 different polyethyleneglycol standards with Mp ~106, ~330, ~420, ~600, ~1500, ~2010, ~3120, ~6240, ~8600, ~12000, ~23000, ~40000; always 4 standards are lyophilised in a 1,5 ml vial (green, red or white); for 1 complete calibration use one of each of the green, red and white vials; 1 set contains 30 vials for 10 complete calibrations
Expand 1 Items
Poly(2-vinylpyridine), analytical standards, Supelco®
Supplier: Merck
GPC Standard, Mw 159,000 (Typical), Supelco®, Glass bottle
Expand 3 Items
Positive electrophoretic mobility standard, NIST-1980
Supplier: LGC Standards PROMOCHEM
This Standard Reference Material (SRM) is intended for use in the evaluation of equipment, and the validation of methodology used to measure electrophoretic mobility.
Expand 1 Items
Test standards for agilent J&W GC column
Supplier: Agilent
GC column test standards contains components that test the column for resolution characteristics, efficiency and inertness.
Expand 8 Items
GC Qualitative standards
Supplier: Agilent
Standard for GC, MIDI system calibration standard
Expand 14 Items
Poly(lauryl methacrylate) solution, Mw 570000 (Typical), average Mn 290000 (Typical), analytical standard, Supelco®
Supplier: Merck
GPC Standard, Poly(lauryl methacrylate) solution, Mw 570000 (Typical), average Mn 290000 (Typical), Supelco®, 25 wt. % in toluene, Analytical standard
Expand 1 Items
Poly(styrenesulfonic acid sodium salt) analytical standards for GPC
Supplier: Merck
GPC Standard, ~2613000 Mw, Mw/Mn ~1,2, Supelco®
Expand 8 Items
Reversed phase test mix, in methanol: water (3:2) (varied conc.), certified reference material, Supelco®
Supplier: Merck
HPLC Standard, Reversed Phase Test Mix, in methanol: water (3:2) (varied conc.), TraceCERT®, Supelco®, Certified reference material, Pk Info: ampule of 1 mL
Expand 1 Items
Poly(acrylic acid), average Mn 130000 (Typical), analytical standard, Supelco®
Supplier: Merck
GPC Standard, Poly(acrylic acid), average Mn 130000 (Typical), Supelco®, Analytical standard
Expand 1 Items
Poly(ethylene glycol) analytical standards, for GPC, Supelco
Supplier: Merck
Poly(ethylene glycol) is the most widely used non-ionic, hydrophilic polymer, which can find wide applications in biomedical industry such as in drug delivery systems.
Expand 1 Items
SEC standards, AdvanceBio
Supplier: Agilent
AdvanceBio SEC Protein Standards are uniquely designed for AdvanceBio SEC columns. The standards are manufactured from a select group of proteins and peptides optimized to deliver accurate, precise quantitation for mAb aggregation and protein analysis.