You searched for: Chromatography Columns
Chromatography columns separate molecules within mixtures during gas or liquid methods. Filled with stationary phase compositions or resins, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual polarity, composition, and size.
GC columns, Stabilwax-MS (fused silica)
Supplier: Restek
Stabilwax-MS columns ensure reproducible retention times from run to run, even with temperature cycling. When methods require trace analysis, this highly polar, low-bleed stationary phase produces excellent signal-to-noise levels. Ideal for food and flavor analysis (e.g., essential oils), fragrance and allergen analysis, as well as industrial solvent and chemical analysis.
Expand 1 Items
PLOT columns, Rt-alumina BOND/Na₂SO₄ columns (fused silica)
Supplier: Restek
Rt-alumina BOND/Na₂SO₄ columns (fused silica PLOT) are used for Na₂SO₄ deactivation.
Expand 3 Items
Analytical guard column, Upchurch Scientific®
Supplier: UPCHURCH SCIENTIFIC
This narrow-bore short column (2,0×20 mm) creates only a slight pressure increase with virtually no detectable theoretical plate loss when used with a 3 mm int.Ø or larger column.
Expand 1 Items
Solid phase extraction cartridges, Bond Elut™ Focus
Supplier: VARIAN
Bond Elut™ Focus solid phase extraction cartridges with enhanced polar recovery. Features a unique amide functionalised polar-enhanced sorbent technology that delivers outstanding retention for polar and non-polar analytes.
Expand 4 Items
Preparative HPLC columns, Ultra Biphenyl
Supplier: Restek
These biphenyl columns offer a greater degree of dispersion than conventional phenyls and a greater degree of polarizability than phenyl hexyls, creating higher selectivity and a greater range of usability. Because of these heightened interactions, this column shows substantial increases in retention—especially for dipolar, unsaturated, or conjugated solutes—and enhanced orthogonal selectivity when using methanol mobile phases.
Expand 3 Items
UHPLC columns, Pinnacle® DB PFP Propyl (USP L43)
Supplier: Restek
Pinnacle® DB PFP Propyl, a unique pentafluorophenyl phase with a propyl spacer, uses a highly base-deactivated spherical silica manufactured by Restek. This highly base-deactivated packing exhibits excellent peak shapes for a wide range of compounds, including nucleosides, nucleotides and halogenated compounds.
Expand 18 Items
HPLC columns, Viva C4 (USP L26)
Supplier: Restek
These columns are based on a wide pore material designed for optimal large-molecule separations. Base-deactivated, wide-pore packing exhibits excellent peak shape for a wide range of compounds. Less retention in reversed phase assays than Viva C18 or Viva C8.
Expand 44 Items
Capillary columns, VF-17ms
Supplier: VARIAN
VF-17ms is a 50% phenyl, 50% dimethylpolysiloxane, medium polarity, low bleed column for increased sensitivity, accuracy and instrument uptime.
Expand 20 Items
PLOT columns, CP-PoraPLOT U and CP-PoraPLOT S
Supplier: VARIAN
CP-PoraPLOT U and CP-PoraPLOT S provide symmetrical peaks from polar and non-polar volatiles for ultimate accuracy.
Expand 6 Items
PLOT column particle traps
Supplier: Restek
When extreme pressure shocks and gas flow changes are anticipated there is a possibility for particles to dislodge. In those cases, using particle traps is recommended.
Expand 2 Items
Capillary columns, CP-Sil 88 for FAME
Supplier: VARIAN
Guaranteed analysis of FAME cis/trans isomers for complete confidence.
Expand 3 Items
HPLC Columns, Raptor™ ARC-18
Supplier: Restek
Raptor™ ARC 18 columns are ideal for high-throughput LC-MS/MS applications with minimal sample preparation.
Expand 15 Items
Solid phase extraction cartridges, Bond Elut™ SI
Supplier: VARIAN
Native silica is generally regarded as the most polar SPE sorbent available. Bond Elut™ SI is particularly effective at separating compounds with a very similar structure. Applying the analytes in a non-polar solvent, then increasing the solvent polarity by increasing the concentration of a polar modifier, such as THF or ethyl acetate, delivers effective separations.
Expand 18 Items
Solid phase extraction cartridges, Bond Elut™ NH₂
Supplier: VARIAN
Bond Elut™ NH₂ is a weaker anion exchanger than sorbents such as SAX (a quaternary amine sorbent that is always charged) and is therefore a better choice for retention of very strong anions, such as sulfonic acids, which may retain irreversibly on a SAX sorbent. Similar to Diol and SI sorbents, Bond Elut™ NH₂ is excellent for the separation of structural isomers.
Expand 24 Items
Solid phase extraction cartridges, Bond Elut™ SAX
Supplier: VARIAN
Bond Elut™ SAX is a strong anion exchange sorbent ideally suited for the extraction of compounds such as carboxylic acids, which may not retain effectively on weak anion exchange sorbents. The sorbent is supplied in the chloride counter ion form. You can modify the selectivity of the phase by replacing the chloride ion with other anions, such as acetate and hydroxide.
Expand 29 Items
Solid phase extraction cartridges, Bond Elut™ C18 OH
Supplier: VARIAN
Bond Elut™ C18 OH is a non-end capped version of the octadecyl bonded phases that enables the silanols on the silica surface to be more active. This low-load C18 has well-controlled silanol activity that permits the fractionation of metabolites and enhances retention of basic compounds compared to an endcapped C18. The pore size makes it a good choice for peptide extraction.
Expand 4 Items
Solid phase extraction cartridges, Bond Elut™ ENV
Supplier: VARIAN
Bond Elut™ ENV, a PS/DVB polymer, is designed for the extraction of polar organic residues. It contains 125 μm spherical particles with a high degree of cross linking, advantageous for high volume, fast flow-through applications.
Expand 8 Items
Solid phase extraction cartridges, Bond Elut™ Alumina
Supplier: VARIAN
Alumina, like silica, is an extremely polar sorbent. The alumina surface tends to be slightly more stable under high pH conditions than unfunctionalised silica. The small particle size of the Bond Elut™ Alumina range ensures high extraction efficiency even when small bed masses are used.
Expand 18 Items
UHPLC columns, Pinnacle® DB PAH UHPLC
Supplier: Restek
Base-deactivated spherical silica that is optimised for UHPLC stability. Designed to resolve complex mixtures of polycyclic aromatic hydrocarbons (PAHs). Complete resolution of all 16 EPA 610 PAHs, plus two other routinely analyzed PAH compounds, in less than five minutes to greatly reduce run times and increase sample throughput.
Expand 3 Items
Solid phase extraction cartridges, EnvirElut™
Supplier: VARIAN
EnvirElut™ sorbents are specially designed for the extraction of a wide range of compounds from aqueous matrices. EnvirElut™ PAH and Pesticides are available in standard SPE straight barrel cartridges, which can be used on conventional vacuum manifolds such as the Vac Elut SPS 24.
Expand 6 Items
Solid phase extraction cartridges, Bond Elut™ C2
Supplier: VARIAN
Bond Elut™ C2 is a fairly non-polar sorbent because of the short chain length of the functional group. C2 is often used during the process of method development if analytes are retained too strongly on a C8 or C18 phase. The polarity of C2 is slightly lower than a cyano phase for polar interactions.
Expand 10 Items
Preparative HPLC columns, Ultra Aqueous C18
Supplier: Restek
Ultra Aqueous C18 is a rugged, reversed phase column with a well balanced retention profile that boasts high reproducibility and compatibility with many mobile phase, even in 100% aqueous conditions.
Expand 12 Items
Solid phase extraction cartridges, Bond Elut™ C8
Supplier: VARIAN
Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.
Expand 23 Items
UHPLC columns, Pinnacle® DB IBD UHPLC (USP L68)
Supplier: Restek
An intrinsically base-deactivated (IBD) phase, containing a polar group within, or intrinsic to, the hydrocarbon bonded phase. Unique selectivity and a high level of base deactivation, while reducing or eliminating the need for mobile phase additives.
Expand 3 Items
UHPLC columns, Pinnacle® DB C8 (USP L7)
Supplier: Restek
Highly base-deactivated spherical silica manufactured by Restek. Monomeric C8 bonding. Similar to Pinnacle® DB C18, but the shorter alkyl chain provides less hydrophobic retention. Less retention can be useful for shortening analysis time, if resolution is adequate. Replaces Hypersil® BDS C8 and Pinnacle® C8 Amine.
Expand 27 Items
Solid phase extraction cartridges, Bond Elut™ CH
Supplier: VARIAN
Bond Elut™ CH is a mid-polarity sorbent that exhibits unique selectivities for certain analytes. When employed as a non-polar sorbent, CH has the approximate polarity of a C₂ sorbent. Bond Elut™ CH is often a good choice when non-polar sorbents such as C₁₈, C₈ or C₂ do not provide the desired selectivity.
Expand 5 Items
UHPLC columns, Ultra Aqueous C18 (USP L1)
Supplier: Restek
Aqueous C18 is a rugged, reversed-phase column with a well-balanced retention profile. It can effectively retain more types of solutes than a conventional C18 and is ideal for multicomponent LC-MS analyses. The general-purpose Aqueous C18 boasts high reproducibility and compatibility with many mobile phase conditions - even 100% aqueous. And when used with a gradient, it eliminates the all-too-common issue of multiple compounds eluting near the column void time.
Expand 12 Items
Capillary columns, CP-Chirasil Val
Supplier: VARIAN
The CP-Chirasil Val columns are designed for the separation of optically active compounds, especially amino acids. They have lower bleed levels than other phases with a Tmax of 200 °C, isothermally and programmed.
Expand 3 Items
Solid phase extraction cartridges, Bond Elut™ Mycotoxin
Supplier: VARIAN
Bond Elut™ Mycotoxin is a novel sorbent which cleans up food extracts for improved trichothecene and zearalenone analysis. Results are comparable or superior to competing methods, including immunoaffinity columns (IaC) and charcoal/alumina columns. The sorbent is a proprietary silica-based ion exchange material.
Expand 1 Items
Capillary columns, CP-Chirasil-Dex CB
Supplier: VARIAN
The CP-Chirasil-Dex CB phase consists of cyclodextrin directly bonded to dimethylpolysiloxane. This bond prevents the cyclodextrin from migrating to different locations in the surface film, delivering homogeneous enantioselectivity throughout the phase.