Bestelling invoeren
Netherlands
Orders LinkContactUsLinkComponent
 

Multi-parameter meter (pH/mV/DO), bench, Orion Star™ A216

Supplier:   Thermo Orion
Multi-parameter meter (pH/mV/DO), bench, Orion Star™ A216
Supplier:  Thermo Orion
Certificates
Multi-parameter meter (pH/mV/DO), bench, Orion Star™ A216

2 Options Available Below

Product Details & Documents

This benchtop meter is ideal for a wide range of applications and advanced pH and dissolved oxygen analysis in the lab. It offers two measuring channels allowing users to measure pH and dissolved oxygen simultaneously or view each channel separately. Can be used with RDO optical or polarographic DO probes.

  • Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
  • Measurement stability indicator and selectable read modes - Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
  • Data log collects and date/time stamps up to 2000 measurement sets with optional sample ID and user ID
  • Calibration log stores ten most recent calibrations
  • Non volatile meter memory ensures your data and settings are protected, even with loss of power
  • Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
  • Flexible power options with universal power adapter or optional AA batteries
  • Three year meter warranty

IP54-rated housing resists dust and splashes and can be wall-mounted if table space is limited.

Measure pH, mV, relative mV or ORP with temperature on channel one and measure dissolved oxygen in percent saturation or mg/L with temperature using RDO optical DO probes or polarographic DO probes on channel two.

Perform up to a five point pH calibration using automatic buffer recognition of NIST or DIN buffer groups with choice to manually enter custom buffer values and calibration editing option that allows individual points to be fixed without a full recalibration. Calibrate dissolved oxygen using water-saturated air, air-saturated water, custom value (Winkler titration) and zero point options.

Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings.

 : Supplied with electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate.
The kit additionally includes: 8157BNUMD ROSS Ultra Triode refillable epoxy-body pH/ATC electrode, 083005MD Polarographic DO sensor with calibration sleeve, ROSS pH buffer and storage solution kit, DO sensor maintenance kit and BOD adapter, funnel and stirrer.

Specifications for Product Family

Specifications

  • Catalog No:
  • 665-0273
  • 665-0274
  • Model:
  • A216
  • A216
  • pH - bereik:
  • –2,000...+20,000
  • –2,000...+20,000
  • pH - resolutie:
  • 0,1/0,01/0,001
  • 0,1/0,01/0,001
  • pH - nauwkeurigheid:
  • ±0,002
  • ±0,002
  • pH - kalibratie:
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • mV - bereik:
  • ±2000,0
  • ±2000,0
  • mV - resolutie:
  • 0,1
  • 0,1
  • mV - nauwkeurigheid:
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • DO concentratie:
  • 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
  • 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
  • Opgeloste zuurstof - resolutie:
  • 0,1/0,01 mg/L
  • 0,1/0,01 mg/L
  • Opgeloste zuurstof - verzadiging:
  • 0 - 600% (polarographic); 0 - 500% (RDO)
  • 0 - 600% (polarographic); 0 - 500% (RDO)
  • DO nauwkeurigheid:
  • Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
  • Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
  • OD kalibratie:
  • Water-saturated air, air saturated water, manual (Winkler) and zero point
  • Water-saturated air, air saturated water, manual (Winkler) and zero point
  • Opgeloste zuurstof - bereik barometerdruk:
  • Automatic or manual, 450 - 850 mm Hg
  • Automatic or manual, 450 - 850 mm Hg
  • Opgeloste zuurstof - bereik:
  • 0,00 - 90,00 mg/L
  • 0,00 - 90,00 mg/L
  • Temperatuurbereik:
  • –5,0...+50,0 °C
  • –5,0...+50,0 °C
  • Temperatuurresolutie:
  • 0,1 °C
  • 0,1 °C
  • Temperatuurnauwkeurigheid:
  • ±0,1 °C
  • ±0,1 °C
  • Temperatuurcompensatie:
  • Automatic or manual
  • Automatic or manual
  • Drukbereik:
  • 400 - 850 mm Hg
  • 400 - 850 mm Hg
  • Aflezing:
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Type accu's:
  • 4 AA (sold separately)
  • 4 AA (sold separately)
  • Gebruiksduur accu's:
  • 800 h
  • 800 h
  • Voeding:
  • AC adapter (included) or 4 AA batteries
  • AC adapter (included) or 4 AA batteries
  • Conformiteit:
  • CE, TUV 3-1, FCC Class A
  • CE, TUV 3-1, FCC Class A
  • Bedrijfstemperatuurbereik:
  • 5...45 °C (ambient)
  • 5...45 °C (ambient)
  • Geheugen - logboekfunctie:
  • Manual/Automatic with AUTO-READ™
  • Manual/Automatic with AUTO-READ™
  • Geheugen capaciteit:
  • 2000 with date and time stamp
  • 2000 with date and time stamp
  • Geheugen:
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Talen:
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • IP-klasse:
  • IP 54
  • IP 54
  • Aansluitingen:
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • Uitgangen:
  • RS232, USB
  • RS232, USB
  • Ingang:
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
  • Alarm:
  • High/low limit alarm, calibration due alarm
  • High/low limit alarm, calibration due alarm
  • Aantal kanalen:
  • 2
  • 2
  • Kalibratie:
  • pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
  • pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
  • Kalibratiepunten:
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • b×d×h:
  • 240×180×110 mm
  • 240×180×110 mm
  • Gewicht:
  • 0,9 kg
  • 0,9 kg

Specifications

Product Family Options

Product Information

  • Omschrijving
    Availability
    Price
  • Bench pH/DO meter Orion Star A216, instrument alone
    Log in for availability
    Log in for availability
    1 * 1 ST
    1 * 1 ST - 2 580,00 €
    2 580,00 €
    1 * 1 ST
       2 580,00 €

    Specifications:
    More
    Specifications
    Cat. No.
    665-0273
    Model
    A216
    pH - bereik
    –2,000...+20,000
    pH - resolutie
    0,1/0,01/0,001
    pH - nauwkeurigheid
    ±0,002
    pH - kalibratie
    Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
    mV - bereik
    ±2000,0
    mV - resolutie
    0,1
    mV - nauwkeurigheid
    ±0,2 mV or ±0,05% of reading, whichever is greater
    DO concentratie
    0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
    Opgeloste zuurstof - resolutie
    0,1/0,01 mg/L
    Opgeloste zuurstof - verzadiging
    0 - 600% (polarographic); 0 - 500% (RDO)
    DO nauwkeurigheid
    Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
    OD kalibratie
    Water-saturated air, air saturated water, manual (Winkler) and zero point
    Opgeloste zuurstof - bereik barometerdruk
    Automatic or manual, 450 - 850 mm Hg
    Opgeloste zuurstof - bereik
    0,00 - 90,00 mg/L
    Temperatuurbereik
    –5,0...+50,0 °C
    Temperatuurresolutie
    0,1 °C
    Temperatuurnauwkeurigheid
    ±0,1 °C
    Temperatuurcompensatie
    Automatic or manual
    Drukbereik
    400 - 850 mm Hg
    Aflezing
    Graphic LCD with backlight
    Type accu's
    4 AA (sold separately)
    Gebruiksduur accu's
    800 h
    Voeding
    AC adapter (included) or 4 AA batteries
    Conformiteit
    CE, TUV 3-1, FCC Class A
    Bedrijfstemperatuurbereik
    5...45 °C (ambient)
    Geheugen - logboekfunctie
    Manual/Automatic with AUTO-READ™
    Geheugen capaciteit
    2000 with date and time stamp
    Geheugen
    Non-volatile memory preserves data log, calibration log and meter settings
    Talen
    English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
    IP-klasse
    IP 54
    Aansluitingen
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Uitgangen
    RS232, USB
    Ingang
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Alarm
    High/low limit alarm, calibration due alarm
    Aantal kanalen
    2
    Kalibratie
    pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
    Kalibratiepunten
    1 point relative mV (RmV) mode, 1 point ORP mode
    b×d×h
    240×180×110 mm
    Gewicht
    0,9 kg
  • Bench pH/DO meter Orion Star A216, kit incl. ROSS Ultra Triode pH/ATC probe and polarographic DO probe
    Log in for availability
    Log in for availability
    1 * 1 ST
    1 * 1 ST - 4 200,00 €
    4 200,00 €
    1 * 1 ST
       4 200,00 €

    Specifications:
    More
    Specifications
    Cat. No.
    665-0274
    Model
    A216
    pH - bereik
    –2,000...+20,000
    pH - resolutie
    0,1/0,01/0,001
    pH - nauwkeurigheid
    ±0,002
    pH - kalibratie
    Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
    mV - bereik
    ±2000,0
    mV - resolutie
    0,1
    mV - nauwkeurigheid
    ±0,2 mV or ±0,05% of reading, whichever is greater
    DO concentratie
    0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
    Opgeloste zuurstof - resolutie
    0,1/0,01 mg/L
    Opgeloste zuurstof - verzadiging
    0 - 600% (polarographic); 0 - 500% (RDO)
    DO nauwkeurigheid
    Polarographic: ±0,2 mg/L or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/L (up to 8 mg/L), ±0,2 mg/L (8 - 20 mg/L), ±10% of reading (up to 50 mg/L)
    OD kalibratie
    Water-saturated air, air saturated water, manual (Winkler) and zero point
    Opgeloste zuurstof - bereik barometerdruk
    Automatic or manual, 450 - 850 mm Hg
    Opgeloste zuurstof - bereik
    0,00 - 90,00 mg/L
    Temperatuurbereik
    –5,0...+50,0 °C
    Temperatuurresolutie
    0,1 °C
    Temperatuurnauwkeurigheid
    ±0,1 °C
    Temperatuurcompensatie
    Automatic or manual
    Drukbereik
    400 - 850 mm Hg
    Aflezing
    Graphic LCD with backlight
    Type accu's
    4 AA (sold separately)
    Gebruiksduur accu's
    800 h
    Voeding
    AC adapter (included) or 4 AA batteries
    Conformiteit
    CE, TUV 3-1, FCC Class A
    Bedrijfstemperatuurbereik
    5...45 °C (ambient)
    Geheugen - logboekfunctie
    Manual/Automatic with AUTO-READ™
    Geheugen capaciteit
    2000 with date and time stamp
    Geheugen
    Non-volatile memory preserves data log, calibration log and meter settings
    Talen
    English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
    IP-klasse
    IP 54
    Aansluitingen
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Uitgangen
    RS232, USB
    Ingang
    BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
    Alarm
    High/low limit alarm, calibration due alarm
    Aantal kanalen
    2
    Kalibratie
    pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
    Kalibratiepunten
    1 point relative mV (RmV) mode, 1 point ORP mode
    b×d×h
    240×180×110 mm
    Gewicht
    0,9 kg
Accessories

Product Information

  • Catalog #
    For
    Availability
    Price
  • Benchtop meter-attached electrode stand (electrode holder arm and head), Orion™ Star A series, 360° motion (without weighted base)
    Benchtop meter-attached electrode stand (electrode holder arm and head), Orion™ Star A series, 360° motion (without weighted base)
    ORIOSTARA-BEA
    Orion Star A110 + A210 series, Orion Versa Star benchtop meters
    Log in for availability
    1 * 1 ST - 261,00 €

Product Information

  • Catalog #
    Availability
    Price
  • Printer and computer cable set, incl. one RS232 printer interface cable and one RS232 computer interface cable
    Printer and computer cable set, incl. one RS232 printer interface cable and one RS232 computer interface cable
    662-1140
    Log in for availability
    1 * 1 EA - 123,00 €

Product Information

  • Catalog #
    Availability
    Price
  • Spare universal power adapter for Thermo Scientific™ Orion™ Star A series benchtop and portable meters and legacy Orion™ Star and Star Plus series meters
    Spare universal power adapter for Thermo Scientific™ Orion™ Star A series benchtop and portable meters and legacy Orion™ Star and Star Plus series meters
    662-1547
    Log in for availability
    1 * 1 ST - 116,00 €

Product Information

  • Catalog #
    Availability
    Price
  • Orion™ Star™ A Series weighted base for use with meter-attached electrode stand
    Orion™ Star™ A Series weighted base for use with meter-attached electrode stand
    ORIOSTARA-HB
    Log in for availability
    1 * 1 ST - 90,10 €

Product Information

  • Catalog #
    Availability
    Price
  • RS232 cable, for connecting a meter to a PC or printer
    RS232 cable, for connecting a meter to a PC or printer
    ORIO1010053
    Log in for availability
    1 * 1 ST - 72,70 €

Product Information

  • Catalog #
    Availability
    Price
  • Cable adapter, for connecting the RS232 port of a meter to a USB port
    Cable adapter, for connecting the RS232 port of a meter to a USB port
    ORIO1010005
    Log in for availability
    1 * 1 ST - 210,00 €

Recommendations

Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".

Otherwise, you will receive generic recommendations.