pH/mV/°C meter, handheld, Orion Star™ A221
This rugged, waterproof portable meter is ideal for a wide range of applications and advanced pH analysis in the field. It measures pH, mV, relative mV or ORP with temperature and can be used in the most demanding locations thanks to its IP 67-rated housing.
- Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
- Up to a five point pH calibration; automatic buffer recognition of NIST or DIN buffer groups with choice to manually enter custom buffer values
- Measurement stability indicator and selectable read modes – Auto-Read holds a stable reading and Continuous shows changing readings with hold option
- Data log collects and date/time stamps up to 1000 measurement sets
- Non volatile meter memory ensures your data and settings are protected, even with loss of power
- Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
- Flexible power options with AA batteries or optional universal power adapter
Designed to offer the reliability you need in a user-friendly package for your dedicated pH testing needs. This waterproof, portable meter displays critical data with your measurement including temperature, date and time, read type, measurement stability, active calibration info and power source status.
Relative humidity range 5 to 85%, non-condensing.
: TUV 3-in-1 and FCC Class A certified.
: Supplied with four with 4 AA batteries, literature CD, printed quick start guide, computer interface cable, meter test certificate and 3-year replacement warranty.
The kit additionally includes: 8107UWMMD ROSS Ultra Triode gel filled epoxy-body pH/ATC electrode (3 m cable), Orion pH 4,01 buffer pouches (10 pack), Orion pH 7,00/pH 10,01 buffer pouches (10 pack each), ROSS electrode storage solution (475 ml), Orion rinse solution pouches (10 pack), Orion Star A series portable meter armor and Orion Star A series hard-sided field case.
The kit additionally includes: 8107UWMMD ROSS Ultra Triode gel filled epoxy-body pH/ATC electrode (3 m cable), Orion pH 4,01 buffer pouches (10 pack), Orion pH 7,00/pH 10,01 buffer pouches (10 pack each), ROSS electrode storage solution (475 ml), Orion rinse solution pouches (10 pack), Orion Star A series portable meter armor and Orion Star A series hard-sided field case.
- Catalog No:
- ORIOSTARA2217
- 662-1444
- 662-1445
- ORIOSTARA2216
- Model:
- A221
- A221
- A221
- A221
- pH range:
- -2,000 – 20,000 pH
- −2,000...+20,000
- −2,000...+20,000
- -2,000 – 20,000 pH
- pH resolution:
- 0,1 / 0,01 / 0,001
- 0,1 / 0,01 / 0,001
- 0,1 / 0,01 / 0,001
- 0,1 / 0,01 / 0,001
- pH accuracy:
- ±0,002
- ±0,002
- ±0,002
- ±0,002
- pH calibration:
- Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
- Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
- Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
- Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
- mV range:
- ±2000,0
- ±2000,0
- ±2000,0
- ±2000,0
- mV resolution:
- 0,1
- 0,1
- 0,1
- 0,1
- mV accuracy:
- ±0,2 mV or ±0,05% of reading, whichever is greater
- ±0,2 mV or ±0,05% of reading, whichever is greater
- ±0,2 mV or ±0,05% of reading, whichever is greater
- ±0,2 mV or ±0,05% of reading, whichever is greater
- Temperature range:
- −5,0...+105,0 °C
- −5,0...+105,0 °C
- −5,0...+105,0 °C
- −5,0...+105,0 °C
- Temperature resolution:
- 0,1 °C
- 0,1 °C
- 0,1 °C
- 0,1 °C
- Temperature accuracy:
- ±0,1 °C
- ±0,1 °C
- ±0,1 °C
- ±0,1 °C
- Temperature compensation:
- Automatic or manual
- Automatic or manual
- Automatic or manual
- Automatic or manual
- Display:
- Graphic LCD with backlight
- Graphic LCD with backlight
- Graphic LCD with backlight
- Graphic LCD with backlight
- Battery life:
- 800 h.
- 800 h.
- 800 h.
- 800 h.
- Power supply:
- 4 AA batteries (included) or universal AC adapter (sold separately)
- AC adapter (not included) or 4 AA batteries
- AC adapter (not included) or 4 AA batteries
- 4 AA batteries (included) or universal AC adapter (sold separately)
- Compliance:
- IP 67
- IP 67
- IP 67
- IP 67
- Operating temperature range:
- 5...45 °C (ambient)
- 5...45 °C (ambient)
- 5...45 °C (ambient)
- 5...45 °C (ambient)
- Data logging - log function:
- Manual / Automatic with AUTO-READ™
- Manual / Automatic with AUTO-READ™
- Manual / Automatic with AUTO-READ™
- Manual / Automatic with AUTO-READ™
- Data logging capacity:
- 1000 with date and time stamp
- 1000 with date and time stamp
- 1000 with date and time stamp
- 1000 with date and time stamp
- Memory:
- Non-volatile memory preserves data log, calibration log and meter settings
- Non-volatile memory preserves data log, calibration log and meter settings
- Non-volatile memory preserves data log, calibration log and meter settings
- Non-volatile memory preserves data log, calibration log and meter settings
- Languages:
- English, Spanish, French, Italian, German, and Chinese (Portuguese and Korean available with software update)
- English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
- English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
- English, Spanish, French, Italian, German, and Chinese (Portuguese and Korean available with software update)
- Connections:
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe)
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe)
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe)
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe)
- Outputs:
- RS232, USB
- RS232, USB
- RS232, USB
- RS232, USB
- Alarm:
- Calibration due alarm (fixed 12 hour)
- Calibration due alarm (fixed 12 hour)
- Calibration due alarm (fixed 12 hour)
- Calibration due alarm (fixed 12 hour)
- No. of channels:
- 1
- 1
- 1
- 1
- Calibration:
- pH, relative mV (RmV), ORP and temperature
- pH, relative mV (RmV), ORP and temperature
- pH, relative mV (RmV), ORP and temperature
- pH, relative mV (RmV), ORP and temperature
- Calibration points:
- 1 (relative mV), 1 (ORP)
- 1 point relative mV (RmV) mode, 1 point ORP mode
- 1 - 5
- 1 - 5
- W×D×H:
- 240×100×65 mm
- 240×100×65 mm
- 240×100×65 mm
- 240×100×65 mm
- Weight:
- 0,5 kg
- 0,5 kg
- 0,5 kg
- 0,5 kg