About this item
The ADP600 high precision polarimeters with internal Peltier temperature control are capable of measuring optical rotation to four decimal places angular across the UV/Visible spectrum using standard glass or low volume leur taper flow-through tubes.
- Touch screen facilitates navigation through user and supervisor menus
- Standard and low volume sample tubes
- Single, double, or multiple wavelengths for UV/Visible applications
- GLP software including date/time/batch
Scientists wishing to measure optical rotation, specific rotation or concentration of optically active samples and chiral compounds to the highest achievable accuracy may do so easily and depending on the model chosen, across a number of wavelengths in the UV/Vis spectrum. The ADP660 six wavelength version is the most versatile and offers extreme sensitivity when using one of the two ultraviolet wavelengths; ideal for measuring very low concentration samples or those with little rotation. The ADP wavelength facilitates measurement of Dextromethorphan Hydrobromide in accordance with pharmacopeia.
The instruments touchscreen user interface facilitates easy navigation through user and supervisor menus. A Methods system facilitates one-touch configuration of the instrument and over 4000 readings may be stored, viewed and output, using the “Print to Secure PDF” function. RFID user clearance offers superior security in FDA controlled environments operating in accordance with 21 CFR Part 11. A log of user activity is also accessed via the touchscreen. Audit trails and electronic signature features are also standard across all models.
These polarimeters meet the requirements of Pharmacopeia (BP/EP/USP/JP) Annex <781> for high performance within academia and research as well as chemical, pharmaceutical, flavours, fragrance and essences manufacturing.
Following extensive consultation with pharmaceutical manufacturers, the on-board software of ADP600 series instruments has been improved to meet not only the needs of the FDA regulation 21 CFR part 11 but also the demanding Data integrity (DI) needs of pharmaceutical manufacturers.
Specifications
- Catalog No:
- BELL37-66
- BELL37-64
- BELL37-65
- BELL37-62
- BELL37-63
- BELL37-61
- Model:
- ADP660
- ADP640
- ADP650
- ADP620
- ADP622
- ADP610
- Angular scale accuracy:
- ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm)
- ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm)
- ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm)
- ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm)
- ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm)
- ±0,003 °A (> 546 nm) ; ±0,005 °A (< 546 nm)
- Angular scale range:
- ±89 °A (−355…+355 nm via Method selection)
- ±89 °A (−355…+355 nm via Method selection)
- ±89 °A (−355…+355 nm via Method selection)
- ±89 °A (−355…+355 nm via Method selection)
- ±89 °A (−355…+355 nm via Method selection)
- ±89 °A (−355…+355 nm via Method selection)
- Angular scale resolution:
- 0,0001 °A
- 0,0001 °A
- 0,0001 °A
- 0,0001 °A
- 0,0001 °A
- 0,0001 °A
- Sugar scale range:
- −225…+225 °Z
- −225…+225 °Z
- −225…+225 °Z
- −225…+225 °Z
- −225…+225 °Z
- −225…+225 °Z
- Display:
- High-resolution touch-screen with colour graphics
- High-resolution touch-screen with colour graphics
- High-resolution touch-screen with colour graphics
- High-resolution touch-screen with colour graphics
- High-resolution touch-screen with colour graphics
- High-resolution touch-screen with colour graphics
- Light source:
- UV/Vis (6 V/2 A over 1000 hours) and narrow band pass filter(s)
- UV/Vis (6 V/2 A over 1000 hours) and narrow band pass filter(s)
- UV/Vis (6 V/2 A over 1000 hours) and narrow band pass filter(s)
- UV/Vis (6 V/2 A over 1000 hours) and narrow band pass filter(s)
- UV/Vis (6 V/2 A over 1000 hours) and narrow band pass filter(s)
- UV/Vis (6 V/2 A over 1000 hours) and narrow band pass filter(s)
- Temperature control accuracy:
- Peltier / ±0,2 °C
- Peltier / ±0,2 °C
- Peltier / ±0,2 °C
- Peltier / ±0,2 °C
- Peltier / ±0,2 °C
- Peltier / ±0,2 °C
- Temperature compensation:
- None, sugar, quartz, user defined
- None, sugar, quartz, user defined
- None, sugar, quartz, user defined
- None, sugar, quartz, user defined
- None, sugar, quartz, user defined
- None, sugar, quartz, user defined
- Temperature range:
- 15 − 35 °C
- 15 − 35 °C
- 15 − 35 °C
- 15 − 35 °C
- 15 − 35 °C
- 15 − 35 °C
- Optical density range (ext.Ø):
- 0,0…3,0
- 0,0…3,0
- 0,0…3,0
- 0,0…3,0
- 0,0…3,0
- 0,0…3,0
- User interface:
- 3× USB (A), USB (B), Ethernet, RS232 (serial)
- 3× USB (A), USB (B), Ethernet, RS232 (serial)
- 3× USB (A), USB (B), Ethernet, RS232 (serial)
- 3× USB (A), USB (B), Ethernet, RS232 (serial)
- 3× USB (A), USB (B), Ethernet, RS232 (serial)
- 3× USB (A), USB (B), Ethernet, RS232 (serial)