U hebt gezocht naar: Organic Standards
Avantor offers a wide range of certified organic standards designed for instrument calibration in ion-exchange chromatography (IC) applications, which can be applied toward environmental or food analysis and quality control. IC is an analytical technique used for the separation and quantification of anions and cations in aqueous samples. Avantor offers high-purity, well-defined reference materials ideal for low-ppm level quantification or trace analysis. Bottles of organic standards are available for a range of elements.
CLP 04.1 B/N matrix spike mix (4 components)
Supplier: Restek
The mix consists of acenaphthene, 2,4-dinitrotoluene, N-nitroso-di-n-propylamine, pyrene.
Expand 1 Items
USP <467> calibration mix #7
Supplier: Restek
The mix consists of chloroform (60 μg/ml), 1,4-dioxane (380 μg/ml), methylene chloride (dichloromethane) (600 μg/ml) and trichloroethene (80 μg/ml).
Expand 1 Items
Chlorinated acids by LC, mix A (8 components)
Supplier: Restek
Consists of eight components, those are acifluorfen, bentazon, chloramben, 2,4-d, dicamba, dichlorprop, picloram and 2,4,5-tp.
Expand 1 Items
Ginkgo biloba (extract), NIST-3247
Supplier: LGC Standards PROMOCHEM
This standard reference material is intended primarily for use in validating analytical methods for the determination of flavonoids, terpene lactones and toxic elements in ginkgo biloba extracts and similar matrices. It can be also used for quality assurance when assigning values to in-house control materials.
Expand 1 Items
DNPH standards, organotin mixtures, CERTAN®
Supplier: LGC Standards PROMOCHEM
These selected organotin compounds are determined by gas chromatography using DIN 38407-F13.
Expand 1 Items
Pharmaceutical Analytical Standard, Low-substituted Hydroxypropylcellulose, Reference Material
Supplier: EDQM
Low-substituted hydroxypropylcellulose EP Reference standard, intended for use in laboratory tests only as specifically prescribed in the European Pharmacopoeia.
Expand 1 Items
3-Methylphenol
Supplier: Restek
This 3-Methylphenol has minimum shelf life six months and maximum shelf life of 96 months.
Expand 1 Items
DHA PONA standard (188 components)
Supplier: Restek
This standard is a qualitative mixture of various gasoline and refinery materials prepared to provide nearly every component that may be encountered in feedstock and finished gasolines. Some oxygenates have been added to allow this blend to be used by refineries for detailed hydrocarbon analysis (DHA) method setup and to fulfill requirements.
Expand 1 Items
8240 Nitriles mix (7 components)
Supplier: Restek
Mix contains: Acrylonitrile (107-13-1); Ethyl methacrylate (97-63-2); Malononitrile (109-77-3); Methacrylonitrile (126-98-7); Methyl methacrylate (80-62-6); Propionitrile (107-12-0); Styrene (100-42-5).
Expand 1 Items
Organophosphorus pesticide mix, 8270 (9 components)
Supplier: Restek
This mix contains 9 components.
Expand 1 Items
Impurity and API standard, L-amoxicillin
Supplier: LGC Standards PROMOCHEM
Organic Standard, (2S,5R,6R)-6-[[(2S)-2-Amino-2-(4-hydroxyphenyl)acetyl]amino]-3,3-dimethyl-7-oxo-4-thia-1-azabicyclo[3.2.0]heptane-2-carboxylic acid
Expand 1 Items
USP <467> calibration mixture #3 (5 components)
Supplier: Restek
The mixture consists of benzene (100 μg/ml), chloroform 50 μg/ml, 1,4-dioxane (100 μg/ml), methylene chloride (dichloromethane) (500 μg/ml) and trichloroethene (100 μg/ml).
Expand 1 Items
8095 calibration mix B (7 components)
Supplier: Restek
The mix consists of, 3,5-dinitroaniline, nitrobenzene, nitroglycerin, 2-nitrotoluene, 3-nitrotoluene, 4-nitrotoluene, PETN.
Expand 1 Items
BAC resolution control standard n-P (6 components)
Supplier: Restek
The mix is use to verify the retention time for each compound normally included in a blood alcohol test, and to verify that the compounds are resolved from and do not interfere with one another.
Expand 1 Items
8095 calibration mix A (10 components)
Supplier: Restek
The mix consists of, 2-amino-4,6-dinitrotoluene, 4-amino-2,6-dinitrotoluene, 1,3-dinitrobenzene, 2,4-dinitrotoluene, 2,6-dinitrotoluene, HMX, RDX, tetryl, 1,3,5-trinitrobenzene, 2,4,6-trinitrotoluene.
Expand 1 Items
TCLP Acid mix (6 components)
Supplier: Restek
TCLP acid mix contains 2-methylphenol (o-cresol), 3-methylphenol (m-cresol), 4-methylphenol (p-cresol), pentachlorophenol, 2,4,5-trichlorophenol, 2,4,6-trichlorophenol.
Expand 1 Items
LC normal phase test mix #1 (4 components)
Supplier: Restek
Routine analysis using this mix can assist in determining the need to perform column and/or system maintenance.
Expand 1 Items
Calibration mix, ASTM D6042-96
Supplier: Restek
ASTM D6042-96 test method is for the determination of phenolic antioxidants and erucamide slip additives in polypropylene homopolymer formulations using liquid chromatography - is a 'consensus' or 'referee' method used among plastic manufacturers and the pharmaceutical companies that purchase plastic containers. Plastic container manufacturers use this test to ensure the quality of their product for their pharmaceutical customers.
Expand 1 Items
Impurity and API standard, (6RS)-3-[2-[4-(6-fluoro-1,2-benzisoxazol-3-yl)piperidin-1-yl]ethyl]-2,6-dimethyl-6,7,8,9-tetrahydro-4H-pyrido[1,2-a]pyrimidin-4-one
Supplier: LGC Standards PROMOCHEM
Organic Standard, (6RS)-3-[2-[4-(6-fluoro-1,2-benzisoxazol-3-yl)piperidin-1-yl]ethyl]-2,6-dimethyl-6,7,8,9-tetrahydro-4H-pyrido[1,2-a]pyrimidin-4-one
Expand 1 Items
Retention time standards
Supplier: Restek
Used during initial sample screening to determine retention time windows for each petroleum product.
Expand 1 Items
SV calibration mix #6 (18 components)
Supplier: Restek
sv calibration mix #6 contains aldrin, α-bhc, β-bhc, δ-bhc, γ-bhc (lindane), 4,4'-DDD, 4,4'-DDE, 4,4'-DDT, dieldrin, endosulphan I, endosulphan II, endosulphan sulphate, endrin, endrin aldehyde, endrin ketone, heptachlor, heptachlor epoxide (isomer B), methoxychlor.
Expand 1 Items
Acetic Acid (31)
Supplier: CUSTOM MADE CHEMICALS LAB
The standard is specially intended for use in testing Japanese pharmacopoeia and monographs. This solution was produced according of Japanese pharmacopoeia specifications using reagent quality components and water meeting the Japanese pharmacopoeia monograph requirement for purified water.
Expand 1 Items
GC multiresidue pesticide standard #2 (40 components)
Supplier: Restek
Accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea and dietary supplements.
Expand 1 Items
8020A Calibration mix (10 components)
Supplier: Restek
Mix contains: Benzene (71-43-2); Chlorobenzene (108-90-7); 1,2-Dichlorobenzene (95-50-1); 1,3-Dichlorobenzene (541-73-1); 1,4-Dichlorobenzene (106-46-7); Ethylbenzene (100-41-4); Toluene (108-88-3); m-Xylene (108-38-3); o-Xylene (95-47-6); p-Xylene (106-42-3).
Expand 1 Items
Trolamine, Reference Standard
Supplier: USP
USP Reference Standards are specified for use in conducting official USP–NF tests and assays. USP also provides Reference Standards specified in the Food Chemicals Codex as well as authentic substances—high-quality chemical samples—as a service to analytical, clinical, pharmaceutical and research laboratories. To confirm accuracy and reproducibility, USP Reference Standards are rigorously tested and evaluated by multiple independent laboratories including USP, commercial, regulatory, and academic labs. USP also provide publicly available, official documentary standards for pharmaceutical ingredients in the USP–NF that link directly with our primary reference standards.
Expand 1 Items
Single - component oxygenates solutions
Supplier: Restek
Certified reference materials (CRMs) manufactured and QC-tested in ISO-accredited labs satisfy your ISO requirements.
Expand 4 Items
SV calibration mix #5/610 PAH mix (16 components)
Supplier: Restek
SV calibration mix contains acenaphthene, acenaphthylene, anthracene, benz(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(ghi)perylene, chrysene, dibenz(a,h)anthracene, fluoranthene, fluorene, indeno(1,2,3-cd)pyrene, naphthalene, phenanthrene, pyrene.
Expand 1 Items
Aldehyde-ketone-DNPH TO-11A calibration mix (15 components)
Supplier: Restek
This consists of acetaldehyde-DNPH; acetone-DNPH; acrolein-DNPH; benzaldehyde-DNPH; n-butyraldehyde-DNPH; crotonaldehyde-DNPH; 2,5-dimethylbenzaldehyde-DNPH; formaldehyde-DNPH; hexaldehyde-DNPH; isovaleraldehyde-DNPH; propionaldehyde-DNPH; m-tolualdehyde-DNPH; o-Tolualdehyde-DNPH; p-tolualdehyde-DNPH and aleraldehyde-DNPH.
Expand 1 Items
GC multi-residue pesticide standard #8 (24 components)
Supplier: Restek
The multiresidue accurately identify and quantify pesticide residues by GC-MS/MS in fruits, vegetables, botanicals, and herbals such as tea, ginseng, ginger, echinacea, and dietary supplements.
Expand 1 Items
PCB congener mix, method 8082A (19 components)
Supplier: Restek
Contains 19 components, those are 2-chlorobiphenyl , 2,3-dichlorobiphenyl , 2,2',5-trichlorobiphenyl , 2,4',5-trichlorobiphenyl, 2,2',3,5'-tetrachlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl, 2,3',4,4'-tetrachlorobiphenyl, 2,2',3,4,5'-pentachlorobiphenyl, 2,2',4,5,5'-pentachlorobiphenyl, 2,3,3',4',6-pentachlorobiphenyl, 2,2',3,4,4',5'-hexachlorobiphenyl, 2,2',3,4,5,5'-hexachlorobiphenyl, 2,2',3,5,5',6-hexachlorobiphenyl, 2,2',4,4',5,5'-hexachlorobiphenyl, 2,2',3,3',4,4',5-heptachlorobiphenyl, 2,2',3,4,4',5,5'-heptachlorobiphenyl, 2,2',3,4,4',5',6-heptachlorobiphenyl, 2,2',3,4',5,5',6-heptachlorobiphenyl and 2,2',3,3',4,4',5,5',6-nonachlorobiphenyl.