Order Entry
Northern Ireland
ContactUsLinkComponent
7803 results for "Restek"

7803 Results for: "Restek"

Sort By
QuEChERS dSPE tubes, Q-sep™

QuEChERS dSPE tubes, Q-sep™

Supplier: Restek

QuEChERS dSPE tubes are used for extract cleanup. It is fast, simple sample Prep for multiresidue pesticide analysis. It has a advantage that no glassware required and it is ready to use. It can be individually labelled for easy sorbent identification and the tubes are preweighed with ultra pure sorbents.

Expand 3 Items
Loading...

Gas-tight syringes, PTFE tipped (SGE)

Supplier: Restek

These tips are used for Agilent autosamplers 7673, 7683, 7693A, and 6850.

Expand 3 Items
Loading...
Replacement needles for Luer lock syringes, gas-tight (SGE)

Replacement needles for Luer lock syringes, gas-tight (SGE)

Supplier: Restek

Needle, Replacement needles, metal hub, Gauge: 18, Length: 50 mm, Type of tip: Needle point style 2

Expand 3 Items
Loading...

DNPH reference materials

Supplier: Restek

The reported concentrations reflect the amount of aldehyde or ketone in the mixture.The concentration of derivatised aldehyde or ketone is not reported.

Expand 2 Items
Loading...
CARB 1004 aldehyde/ketone-DNPH calibration standard (13 components)

CARB 1004 aldehyde/ketone-DNPH calibration standard (13 components)

Supplier: Restek

The CARB 1004 aldehyde/ketone-DNPH calibration standard consists of 13 components, they are acetaldehyde-2,4-DNPH, acetone-2,4-DNPH, acrolein-2,4-DNPH, benzaldehyde-2,4-DNPH, n-butyraldehyde-2,4-DNPH, crotonaldehyde-2,4-DNPH, formaldehyde-2,4-DNPH, hexaldehyde-2,4-DNPH, methacrolein-2,4-DNPH, methyl ethyl ketone-2,4-DNPH, propionaldehyde-2,4-DNPH, m-tolualdehyde-2,4-DNPH, valeraldehyde-2,4-DNPH.

Expand 1 Items
Loading...
Preparative HPLC columns, ultra PFP propyl

Preparative HPLC columns, ultra PFP propyl

Supplier: Restek

Ultra PFP (pentafluorophenyl) Propyl preparative columns are ideal for the retention and selectivity of charged bases, electronegative compounds, and amine-containing compounds.

Expand 7 Items
Loading...
Analytical HPLC columns, Ultra Aromax (USP L11)

Analytical HPLC columns, Ultra Aromax (USP L11)

Supplier: Restek

These Ultra Aromax is a unique reversed-phase material that exhibits extreme retention and selectivity for aromatic and/or unsaturated compounds. They are made of high-purity, type-B silica that minimises activity and creates high-density bonding, these columns are designed for selective and reliable HPLC applications.

Expand 71 Items
Loading...
SV calibration mix #5/610 PAH mix (16 components)

SV calibration mix #5/610 PAH mix (16 components)

Supplier: Restek

SV calibration mix contains acenaphthene, acenaphthylene, anthracene, benz(a)anthracene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(ghi)perylene, chrysene, dibenz(a,h)anthracene, fluoranthene, fluorene, indeno(1,2,3-cd)pyrene, naphthalene, phenanthrene, pyrene.

Expand 1 Items
Loading...
Capillary columns, Rxi®-17 (fused silica)

Capillary columns, Rxi®-17 (fused silica)

Supplier: Restek

These Rxi®-17 general purpose columns are suitable for pesticides, herbicides, rosin acids, phthalate esters, triglyceridesa and sterols.

Expand 1 Items
Loading...
GC septa, BTO® septa

GC septa, BTO® septa

Supplier: Restek

These septa are preconditioned and ready to use.

Expand 16 Items
Loading...
8330 calibration mix #1 (7 components)

8330 calibration mix #1 (7 components)

Supplier: Restek

EPA method 8330 is used to measure explosives residues in water and soil samples, using HPLC with UV detection. Target analytes are nitroaromatic and nitramine explosives and their degradation products. Obtaining pure, neat compounds for Method 8330 reference standards can be very difficult. To ensure the highest quality standards, Restek's Quality Control (QC) lab confirms the identity and purity of mixture components and solvents using one or more of the following techniques: GC-FID, HPLC, GC-ECD, GC-MS, LC-MS, refractive index, and melting point.

Expand 1 Items
Loading...
FAME #13 mix

FAME #13 mix

Supplier: Restek

This mixture can be used for quantification (AOCS method CE 1a–13) and approximate the compositions of oils.

Expand 1 Items
Loading...
FAME #17 mix (5 components)

FAME #17 mix (5 components)

Supplier: Restek

This mixture can be used for quantification (AOCS Method CE 1a–13) and approximate the compositions of the types of oils like linseed, perilla, hempseed and rubberseed oil.

Expand 1 Items
Loading...
FAME #8 mix

FAME #8 mix

Supplier: Restek

This mixture can be used for quantification (AOCS method CE 1a–13) and approximate the compositions of oils.

Expand 1 Items
Loading...
FAME #5 mix

FAME #5 mix

Supplier: Restek

This mixture can be used for quantification (AOCS method CE 1a–13) and approximate the compositions of oils.

Expand 1 Items
Loading...
FAME #1 mix

FAME #1 mix

Supplier: Restek

This mixture can be used for quantification (AOCS method CE 1a–13) and approximate the compositions of oils.

Expand 1 Items
Loading...
Capillary columns, Rtx®-35 (fused silica)

Capillary columns, Rtx®-35 (fused silica)

Supplier: Restek

General-purpose columns for organochlorine pesticides, PCB congeners (e.g. Aroclor mixes), herbicides, pharmaceuticals, sterols, rosin acids, phthalate esters.

Expand 15 Items
Loading...
Hexachlorobenzene

Hexachlorobenzene

Supplier: Restek

Organic Standard, Hexachlorobenzene, 1 ml/ampoule

Expand 1 Items
Loading...
δ-BHC

δ-BHC

Supplier: Restek

Organic Standard, δ-BHC, 1 ml/ampoule

Expand 1 Items
Loading...
Pesticide reference standard, Propachlor

Pesticide reference standard, Propachlor

Supplier: Restek

Organic Standard, Propachlor, Pack type: Glass bottle

Expand 1 Items
Loading...
508.1 calibration mix #3 (8 components)

508.1 calibration mix #3 (8 components)

Supplier: Restek

Consists of eight components, those are alachlor, atrazine, chlorothalonil, cyanazine , hexachlorocyclopentadiene, metolachlor, metribuzin and simazine.

Expand 1 Items
Loading...
CarboBlack columns (packed), silco smooth tubing

CarboBlack columns (packed), silco smooth tubing

Supplier: Restek

Graphitised carbon black offers unique selectivity and very little adsorption for alcohol analyses. Two types of CarboBlack supports are available, CarboBlack B and CarboBlack C. CarboBlack B support, with its higher surface area, can hold up to a 10% loading of a non silicone liquid phase. CarboBlack C support can hold up to a 1% loading of a non silicone liquid phase.

Expand 70 Items
Loading...
Guard/retention gap columns, hydroguard® water-resistant (fused silica)

Guard/retention gap columns, hydroguard® water-resistant (fused silica)

Supplier: Restek

Extend analytical column lifetime by preventing degradation from harsh 'steam-cleaning' water injections.

Expand 9 Items
Loading...

Pesticide reference standard, 2-Chloronaphthalene 1,000 µg/ml in methanol

Supplier: Restek

Organic Standard, 2-Chloronaphthalene 1,000 µg/ml in methanol, Pack type: Glass ampoule

Expand 2 Items
Loading...

Organic reference standard, 1-Methylnaphthalene 1000 µg/ml in methanol

Supplier: Restek

Organic Standard, 1-Methylnaphthalene 1,000 µg/ml in methanol, Pack type: Glass ampoule

Expand 2 Items
Loading...
Filters for extraction cells, ASE® 200 systems

Filters for extraction cells, ASE® 200 systems

Supplier: Restek

These filter are made of cellulose or glass fibre. Ideal for ASE® 200 extraction cells.

Expand 1 Items
Loading...
2,4'-DDT

2,4'-DDT

Supplier: Restek

Organic Standard, 2,4'-DDT, 1 ml/ampoule

Expand 1 Items
Loading...
VOA internal standard mix (3 components)

VOA internal standard mix (3 components)

Supplier: Restek

Mix contains: Bromochloromethane (74-97-5), 1,4-Difluorobenzene (540-36-3), Chlorobenzene-d5 (3114-55-4).

Expand 1 Items
Loading...
Gasoline surrogate and internal standards, VOA Mixes

Gasoline surrogate and internal standards, VOA Mixes

Supplier: Restek

Certified reference materials (CRMs) manufactured and QC-tested in ISO-accredited labs satisfies ISO requirements.

Expand 6 Items
Loading...
GC columns, chromosorb diatomaceous earth

GC columns, chromosorb diatomaceous earth

Supplier: Restek

These bonded stationary phase packed columns are used in capillary columns which provide a dramatic increase in column quality.

Expand 12 Items
Loading...
Sort By
Recommended for You