Conductivity meter, handheld, Orion Star™ A322
Supplier: Thermo Orion
This portable conductivity meter is designed for a wide range of conductivity, total dissolved solids (TDS), salinity, resistivity and temperature testing and field applications. The meter is suitable for use in the most demanding locations thanks to its IP 67-rated housing.
Expand 3 Items
Conductivity meter, bench, Orion™ Star™ A212
Supplier: Thermo Orion
The Orion™ Star™ A112 conductivity benchtop meter is ideal for a wide range of applications and advanced conductivity analysis in the lab. It reliably measures conductivity, total dissolved solids, salinity, resistivity and temperature values.
Expand 3 Items
Iron(II) sulphate heptahydrate ≥99%, bluish green granular powder cell culture reagent
Supplier: MP Biomedicals
Storage: Room Temperature, desiccate, store under nitrogen.
Ferrous sulfate heptahydrate is a reagent used in the manufacturing of iron compounds, in electroplating baths, aluminium etching, process engraving and lithography, and in redox polymerisation. It is used as a reducing agent in chemical processes, leather dyes and writing inks. Also, it is a component of weed killers, wood preservatives and water treatment processes. Used In prevention of chlorosis in plants and therapeutically as hematinic. In veterinary medicine, it is used as an astringent to combat iron deficiency. Ferrous sulfate heptahydrate is used in the determination of phosphorus as per the method of Taussky and Shorr. Ferrous sulfate heptahydrate is used in cell culture applications generally bound to transferrin, citrate or other iron transport molecules.
Expand 2 Items
Mercury (I) (Mercurous) Nitrate 0.1M (0.1N) CRM, ISO 17034 and ISO 17025,,,, Conservation 12 months. ,,,, Store under normal laboratory conditions, at temperatures between 15C to 25C 1 * 500 mL
Supplier: CUSTOM MADE CHEMICALS LAB
Mercury (I) (Mercurous) Nitrate 0.1M (0.1N) CRM, ISO 17034 and ISO 17025,,,, Conservation 12 months. ,,,, Store under normal laboratory conditions, at temperatures between 15C to 25C 1 * 500 mL
Expand 1 Items
ELECTROPHORESIS SYSTEM 1 * 1 items
Supplier: IBI SCIENTIFIC
ELECTROPHORESIS SYSTEM 1 * 1 items
Expand 1 Items
Environmental Standards - 4 components: 1000mg/l each of Ca K Mg Na in HNO3 5% CRM, ISO 17034 and ISO 17025 Conservation 36 months. (12 months after opening) Store under normal laboratory conditions, at temperatures between 15C to 25C 1 * 100 mL
Supplier: CUSTOM MADE CHEMICALS LAB
Environmental Standards - 4 components: 1000mg/l each of Ca K Mg Na in HNO3 5% CRM, ISO 17034 and ISO 17025 Conservation 36 months. (12 months after opening) Store under normal laboratory conditions, at temperatures between 15C to 25C 1 * 100 mL
Expand 1 Items
PETRI DISH 90MM 3 COMP./3 VENTS IRRAD 1 * 500 items
Supplier: Anicrin
PETRI DISH 90MM 3 COMP./3 VENTS IRRAD 1 * 500 items
Expand 1 Items
BOTTLE HDPE SQUARE 25ML WITH GASKET 19MM 1 * 180 items
Supplier: LP ITALIANA
BOTTLE HDPE SQUARE 25ML WITH GASKET 19MM 1 * 180 items
Expand 1 Items
AMMONIUM STANDARD SOLUTION (1 PPM NH4) 1 * 100 mL
Supplier: CPACHEM
AMMONIUM STANDARD SOLUTION (1 PPM NH4) 1 * 100 mL
Expand 1 Items
Anti-SLC25A20 Rabbit Polyclonal Antibody
Supplier: ProSci Inc.
SLC25A20 is one of several closely related mitochondrial-membrane carrier proteins that shuttle substrates between cytosol and the intramitochondrial matrix space.It mediates the transport of acylcarnitines into mitochondrial matrix for their oxidation by the mitochondrial fatty acid-oxidation pathway. Mutations in this gene are associated with carnitine-acylcarnitine translocase deficiency, which can cause a variety of pathological conditions such as hypoglycemia, cardiac arrest, hepatomegaly, hepatic dysfunction and muscle weakness, and is usually lethal in new born and infants.This gene product is one of several closely related mitochondrial-membrane carrier proteins that shuttle substrates between cytosol and the intramitochondrial matrix space. This protein mediates the transport of acylcarnitines into mitochondrial matrix for their oxidation by the mitochondrial fatty acid-oxidation pathway. Mutations in this gene are associated with carnitine-acylcarnitine translocase deficiency, which can cause a variety of pathological conditions such as hypoglycemia, cardiac arrest, hepatomegaly, hepatic dysfunction and muscle weakness, and is usually lethal in new born and infants. Publication Note: This RefSeq record includes a subset of the publications that are available for this gene. Please see the Entrez Gene record to access additional publications.
Expand 1 Items
Cleanroom vacuum cleaner, CR-1200D
Supplier: TIGER-VAC
New generation cleanroom vacuum cleaners available in dry recovery. Designed specifically for the pharmaceutical, semiconductor and microelectronics industry.
Expand 3 Items
Affinity purification media, rProtein A Sepharose™ Fast Flow
Supplier: Cytiva
rProtein A Sepharose™ 4 Fast Flow is a well established antibody affinity medium is designed for the purification of monoclonal and polyclonal antibodies based on Sepharose™ Fast Flow platform. The recombinant protein A is produced in E.coli and engineered for an oriented coupling to giving a matrix with enhanced binding capacity. The epoxy-based coupling ensures low ligand leakage. The specificity of the recombinant protein A for the Fc region of IgG is similar to native protein A and provides excellent purification in one step. The high capacity, low ligand leakage and a well established base matrix makes rProtein A Sepharose™ Fast Flow ideal for purification of monoclonal antibodies at both laboratory and process scale.
Expand 1 Items
Mini vertical electrophoresis system, miniVE
Supplier: Cytiva
The simple, modular design of miniVE vertical electrophoresis system consolidates all the small parts for electrophoresis and blotting into one convenient unit. Uniform gel temperature is maintained with the tank-style lower buffer chamber. A full tank stabilises the temperature so that lanes are straight and bands are flat. The blot module will accept two gel/membrane stacks simultaneously. The lower buffer chamber is designed to hold two blot modules, allowing four gels to be blotted at once.
Expand 1 Items
Electroporation system, twin-wave, Gemini X² and SC
Supplier: BTX
Gemini twin-wave electroporators are flexible systems allowing both square wave and exponential decay wave electroporation in a single unit. These waveform combinations enable researchers to easily and efficiently electroporate eukaryotic and prokaryotic cells in cuvettes or plates with one easy to use set-up. Ideal for all the electroporation needs, including CRISPR, in vivo, in vitro, in ovo and more.
Expand 1 Items
Accessories for Fast DNA™ and Fast DNA™ SPIN Kits, MP Biomedicals
Supplier: MP Biomedicals
Nucleic Acid Purification Kits and Reagents, PPS solution
Expand 1 Items
Safety storage container stainless steel 25L with tab and pressure-relief valve. Heigth 530 mm, diameter 260mm, thread 1 1/2 thread, outflowing side 3/4 . Not UN approval 1 * 1 items
Supplier: BURKLE
Safety storage container stainless steel 25L with tab and pressure-relief valve. Heigth 530 mm, diameter 260mm, thread 1 1/2 thread, outflowing side 3/4 . Not UN approval 1 * 1 items
Expand 1 Items
203mm Diameter Stainless Steel Test Sieve with Electroformed Sheet 1 * 1 items
Supplier: Retsch GmbH
203mm Diameter Stainless Steel Test Sieve with Electroformed Sheet 1 * 1 items
Expand 1 Items
Refill-Therm. AMA-Exact, -10+150:1C, enclosed scale, cap. colourless, red special liquid, richter-top finish without button, lower part 250x8-8,5mm, upper part 250xc.10mm, suitable for government verification, null
Supplier: Amarell
Refill-Therm. AMA-Exact, -10+150:1C, enclosed scale, cap. colourless, red special liquid, richter-top finish without button, lower part 250x8-8,5mm, upper part 250xc.10mm, suitable for government verification, null
Expand 1 Items
8 components 100mg/l each of Al Au Cr Mo Na Sb Sn Te in HCl 2% . Duree de conservation : 12 mois a ouverture du flacon, Duree de validite: 24 mois. Store under normal laboratory conditions, at temperatures between 15 to 25C 1 * 100 mL
Supplier: CUSTOM MADE CHEMICALS LAB
8 components 100mg/l each of Al Au Cr Mo Na Sb Sn Te in HCl 2% . Duree de conservation : 12 mois a ouverture du flacon, Duree de validite: 24 mois. Store under normal laboratory conditions, at temperatures between 15 to 25C 1 * 100 mL
Expand 1 Items
Amersham CyDye DIGE fluors
Supplier: Cytiva
CyDye™ DIGE fluors are available as minimal and saturation labeling dyes. The minimal dyes are intended for general 2-D application use where sufficient amounts of sample are available. The saturation dyes from the Scarce Sample Labeling Kit are designed to be used for applications where only small amounts of sample are available, for example in Laser Capture Microdissection.
Expand 3 Items
Anti-MYD88 Mouse Monoclonal Antibody [clone: 2E9C2 ]
Supplier: ProSci Inc.
MyD88 Monoclonal Antibody: The pro-inflammatory cytokine IL-1 induced cellular response requires IL-1 receptor complex including IL-1RI and IL-1RAcP. MyD88 has been identified as an adapter molecule in the IL-1 signaling pathway. MyD88 associates with and recruits IRAK to the IL-1 receptor complex in response to IL-1 treatment and dominant negative form of MyD88 attenuates IL-1R-mediated NF-κB activation. MyD88 is also employed as a regulator molecule by IL-18 receptor and human Toll receptor, which are members in the Toll/IL-1R family of receptors. Targeted disruption of the MyD88 gene results in lose of cellular responses to IL-1 and IL-18, and MyD88-deficient mice lack responses to bacterial product LPS that employs Toll-like receptors 2 and 4 (TLR2 and TLR4) as the signaling receptors. MyD88 is a general adapter protein for the Toll/IL-1R family of receptors and plays an important role in the inflammatory response induced by cytokines IL-1 and IL-18 and endotoxin. MyD88 gene is expressed in many tissues.
Expand 1 Items
VWR® LED and LCD Ultrasonic Cleaning Baths
Supplier: VWR Collection
The housing and tank are constructed from high-quality SUS 304 stainless steel, providing durability and longevity. Equipped with user-friendly interface display which offers intuitive function selection and real-time parameter setting. Units also feature intelligent detection on startup, promptly alerting users to any potential issues via buzzer and alarm. Additionally, they continuously monitor the power supply voltage in real-time to ensure optimal operating conditions. The automatic heating stirring function ensures uniform liquid temperature throughout the tank. The anti-leakage tray prevents damage to electrical components and avoids the risk of hazard in case of leakage.
Expand 1 Items
MICROSYRINGE 25µL GAS ANALYSIS MS/GF INTERCHANGEABLE NEEDLE 1 * 1 items
Supplier: Hospidex
MICROSYRINGE 25µL GAS ANALYSIS MS/GF INTERCHANGEABLE NEEDLE 1 * 1 items
Expand 1 Items
TCEP-HCl (Tris(2-carboxyethyl)phosphine hydrochloride), No-Weigh™ Format, Pierce™
Supplier: Thermo Fisher Scientific
Thermo Scientific Pierce TCEP-HCl is a potent, versatile, odorless, thiol-free reducing agent with broad application to protein and other research involving reduction of disulfide bonds. The unique compound is easily soluble and very stable in many aqueous solutions. TCEP reduces disulfide bonds as effectively as dithiothreitol (DTT), but unlike DTT and other thiol-containing reducing agents, TCEP does not have to be removed before certain sulfhydryl-reactive crosslinking reactions.
Expand 1 Items
Pierce™ Silver Stain for Mass Spectrometry
Supplier: Thermo Fisher Scientific
Pierce silver stain for mass spectrometry is a complete kit for rapid and ultra-sensitive silver staining of proteins in polyacrylamide gels and efficient destaining of excised gel pieces for mass spectrometry analysis. This kit enables both first-time and experienced users to achieve consistent and reliable staining using high, low, and gradient-percentage gels in 1D and 2D formats. The optimised staining method ensures extremely sensitive staining while minimizsing covalent crosslinking of protein to the gel matrix, which can inhibit protein recovery. The destaining reagents facilitate complete removal of silver from stained protein bands and maximum protein recovery for subsequent mass spectrometry analysis.
Expand 1 Items
Singlet Single-use Conductivity Standard Solution, 147 µ S/cm, KCl, 20 mL 1 * 20 items
Supplier: Hach
Singlet Single-use Conductivity Standard Solution, 147 µ S/cm, KCl, 20 mL 1 * 20 items
Expand 1 Items
illustra™ Hot Start mix, Ready-To-Go™
Supplier: Cytiva
illustra™ Hot Start Mix, Ready-To-Go™ is a pre-formulated and pre-dispensed, freeze-dried PCR reagent mix, including high quality PuReTaq™ DNA polymerase and a hot start activator protein, for increased specificity and reproducibility of PCR amplifications. The Ready-To-Go™ beads are provided in either 0,5 or 0,2 ml tubes that are compatible with most thermal cyclers.
Expand 3 Items
EDC-HCl (N-(3-Dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride), Pierce™
Supplier: Thermo Fisher Scientific
Thermo Scientific Pierce EDC is a carboxyl- and amine-reactive zero-length crosslinker. EDC reacts with a carboxyl group first and forms an amine-reactive O-acylisourea intermediate that quickly reacts with an amino group to form an amide bond with release of an isourea by-product. The intermediate is unstable in aqueous solutions and so two-step conjugation procedures rely on N-hydroxysuccinimide (NHS) for stabilization. Failure to react with an amine will result in hydrolysis of the intermediate, regeneration of the carboxyl, and release of an N-substituted urea. A side reaction is the formation of an N-acylurea, which is usually restricted to carboxyls located in hydrophobic regions of proteins.
Expand 1 Items
Anti-ORAI3 Mouse Monoclonal Antibody [clone: 2H2G9 ]
Supplier: ProSci Inc.
ORAI3 Monoclonal Antibody: Antigen stimulation of immune cells triggers Ca++ entry t hrough Ca++ release-activated Ca++ (CRAC) channels. ORAI3 is one of two mammalian homologs to ORAI1, a recently identified four-transmembrane spanning protein that is an essential component of CRAC. All three homologs have been shown to function as Ca++ plasma membrane channels gated through interactions with STIM1, the store-activated endoplasmic reticulum Ca++ sensor. However, ORAI3 channels failed to produce detectable Ca++ selective currents in cells co-transfected with ORAI3 and STIM1, indicating that ORAI3 channels undergo a lesser degree of depotentiation than ORAI1 or ORAI2. Na+ currents through ORAI1, 2 and 3 channels were equally inhibited by extracellular Ca++, indicating that each have similar affinities for Ca++ within the selectivity filter. This antibody is predicted to have no cross-reactivity to ORAI1 or ORAI2. Larger molecular weight bands are sometimes seen in SDS-PAGE; these may represent post-translationally modified ORAI 3.