33218 Results for: "Furnace Cap Hood"
Magnesium nitrate 10 g/L (99,999%) in water, ARISTAR® matrix modifier solution, for graphite furnace AAS
Supplier: VWR Chemicals
The VWR® Matrix modifier solutions have especially been developed for use in GF-AAS to eliminate matrix effects. They can be used either diluted or as mixtures.
Expand 1 Items
Carbon black ≥99.9%, acetylene, 100% compressed
Supplier: Thermo Fisher Scientific
Carbon black ≥99.9%, acetylene, 100% compressed
Expand 2 Items
Carbon black ≥99.9%, acetylene, 50% compressed
Supplier: Thermo Fisher Scientific
Carbon black ≥99.9%, acetylene, 50% compressed
Expand 4 Items
Ashing Furnaces with Fold Down Door, Optional Controller C550 and Integrated Post Combustion, Tmax 1100 °C, L 9/11 BO
Supplier: NABERTHERM
The BO series is specially designed for processes in which larger sample quantities must be incinerated. Mainly used in the fields such as ashing of food, thermal cleaning of injection molding tools or determination of annealing loss.
Expand 4 Items
Muffle furnaces with fold down door, Tmax 1100 °C and controller R7, LE series (LE 1/11 - LE24/11)
Supplier: NABERTHERM
With their convincing price/performance ratio and the fast heat-up rates, these compact muffle furnaces are perfect for many applications in the laboratory. Quality features like the dual-shell furnace housing of rust-free stainless steel and their compact, lightweight construction. The heating elements encased in quartz glass tubes make these models reliable partners for your application. The furnaces have Tmax 1100 °C, working temperature of 1050 °C.
Expand 5 Items
Charging plates for furnaces, N 7 - N 641/13
Supplier: NABERTHERM
Charging plate, heat resistant alloy 314, for N 7H furnace, use up to 1100 °C to protect the furnace floor , Nabertherm
Expand 5 Items
Carbon black ≥99% (metals basis), Super P® Conductive
Supplier: Thermo Fisher Scientific
Carbon black ≥99% (metals basis), Super P® Conductive
Expand 2 Items
Compact Tube Furnaces R and RD Series
Supplier: NABERTHERM
These compact bench top tube furnaces with integrated controllers can be widely used for a variety of processes. Equipped with a standard C 530 ceramic working tube and two fibre plugs they have an unbeatable price/performance ratio. Units feature rust-free, textured stainless steel exteriors. R models feature Tmax 1200 or 1300 °C, RD models have Tmax 1100 or 1300 °C.
Expand 29 Items
Ammonium dihydrogen phosphate 20 g/L in nitric acid 1%, ARISTAR® matrix modifier solution, for graphite furnace AAS
Supplier: VWR Chemicals
The VWR® Matrix modifier solutions have especially been developed for use in GF-AAS to eliminate matrix effects. They can be used either diluted or as mixtures.
Expand 1 Items
Palladium nitrate and magnesium nitrate, matrix modifier solution, Specpure®
Supplier: Thermo Fisher Scientific
Pre-mixed matrix modifier are designed for use with graphite furnace atomic absorption (GFAA).
Expand 1 Items
High-temperature furnaces with fold down door and SiC rod, heating up to 1600 °C, LHTC models
Supplier: NABERTHERM
The durability of the SiC rods in periodic use, in combination with their high heating speed, make these high-temperature furnaces good all-rounders in the laboratory. Heating times of 40 minutes to 1400 °C can be achieved, depending on the furnace model and the conditions of use.
Expand 8 Items
Ammonium dihydrogen phosphate 100 g/L in nitric acid 1%, ARISTAR® matrix modifier solution, for graphite furnace AAS
Supplier: VWR Chemicals
The VWR® Matrix modifier solutions have especially been developed for use in GF-AAS to eliminate matrix effects. They can be used either diluted or as mixtures.
Expand 1 Items
Ammonium nitrate 50 g/L (99,999%) in water, ARISTAR® matrix modifier solution, for graphite furnace AAS
Supplier: VWR Chemicals
The VWR® Matrix modifier solutions have especially been developed for use in GF-AAS to eliminate matrix effects. They can be used either diluted or as mixtures.
Expand 1 Items
Palladium nitrate and magnesium nitrate, matrix modifier solution, Specpure®
Supplier: Thermo Fisher Scientific
Pre-mixed matrix modifier are designed for use with graphite furnace atomic absorption (GFAA).
Expand 1 Items
Muffle furnaces with lift up door, Tmax 1100 °C and standard controller B 510, LT 3/11 - LT 60/11
Supplier: NABERTHERM
LT 3/11 - LT 60/11 muffle furnaces are the ideal choice for daily laboratory use. These high quality models have an advanced and attractive design, are very reliable and have a lift-up door as standard.
Expand 1 Items
Multi-element QC-21 check standard solution, Specpure®
Supplier: Thermo Fisher Scientific
Multi-Element QC-21 Check Standard Solution is used as a certified reference material or quality control check standard for inductively coupled plasma optical emission spectroscopy (ICP-OES). It is also used in inductively coupled plasma mass spectrometry (ICP-MS), and flame or furnace atomic absorption spectroscopy.
Expand 2 Items
Accessories for muffle furnaces
Supplier: Thermo Fisher Scientific
Hearth tray for benchtop F48000 muffle furnace
Expand 9 Items
Deutrium furnace kit, GTA 120
Supplier: VARIAN
GTA 120 deuterium graphite furnace AA operating supplies kit.
Expand 3 Items
Lindberg/Blue M Moldatherm Box Furnace
Supplier: Thermo Fisher Scientific
Lindberg/Blue M Moldatherm box furnaces are versatile selection for a variety of industrial and laboratory applications.
Expand 2 Items
Cryo-Compact circulators, CF series
Supplier: JULABO GmbH
Compact refrigerated/heating circulators which can be used on benchtop or in a fume hood, ideal for temperature control of distillation apparatus or mini plant installation. All four models feature pump connections for external temperature applications and a bath opening for temperature control of small objects directly in the circulator bath. The maximum ambient temperature of +40 °C and air cooled ventilation means the units can be positioned alongside other units or directly in a fume hood.
Expand 4 Items
PSD spares and supplies
Supplier: VARIAN
The Programmable Sample Dispensers (PSD) are high-capacity autosamplers that are used with Graphite Furnace AA.
Expand 4 Items
Combustion boats
Supplier: MORGAN ADVANCED MATERIALS HALD
Boats, made of porcelain, unglazed, with eyelet to aid recovery from furnace.
Expand 1 Items
Accessories for Muffle Furnace M110
Supplier: Thermo Scientific
Bottom tray
Expand 1 Items
Miscellaneous supplies for PerkinElmer
Supplier: Agilent
Agilent supplies are equivalent to PerkinElmer AA supplies, so you can be confident that they will integrate seamlessly with your PerkinElmer system.
Expand 2 Items
Contact cylinders for PerkinElmer
Supplier: Agilent
Agilent uses high-quality graphite and applies stringent quality controls to ensure contamination free and consistency of our contact cylinders for your PerkinElmer graphite furnace AA system. The standard THGA graphite contact cylinders, feature a modified injection port area that helps to minimise condensation and improve analytical performance with difficult matrices. The HGA contact cylinders have shaped graphite contacts to completely encase the graphite tube, ensuring the tube is positioned in a defined environment for uniform radiation conditions.
Expand 5 Items
Reference Materials, Matrix Modifiers for GFAA, CRM, VHG, Promochem
Supplier: LGC Standards PROMOCHEM
This solution is intended for use as a matrix modifier for graphite furnace atomic absorption spectroscopy (GFAA) in the determination of trace elements.
Expand 4 Items
Graphite platforms for PerkinElmer
Supplier: Agilent
These graphite platforms and tubes for PerkinElmer graphite furnace AA systems are quality tested to ensure every batch passes our demanding performance specifications for contamination, sensitivity, precision, electrical resistance, and lifetime.
Expand 2 Items
Accessories for autosamplers, AS series
Supplier: PerkinElmer
Sampling capillary for solvent and acid resistant sampling components, For: AS-60, AS-70, AS-71, AS-72 and AS-800 graphite furnace autosamplers
Expand 1 Items
Cadmium standard solutions, for ICP, in 5% HNO₃, VHG
Supplier: LGC Standards PROMOCHEM
The solutions are intended for use as a certified reference material or calibration standard for inductively coupled plasma optical emission spectroscopy (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), flame or furnace atomic absorption spectroscopy (AA or GFAA), x-ray fluorescence spectroscopy (XRF), and other techniques for elemental analysis.
Expand 4 Items
Bismuth standard solution, for ICP, in 5% HNO₃, VHG
Supplier: LGC Standards PROMOCHEM
The solutions are intended for use as a certified reference material or calibration standard for inductively coupled plasma optical emission spectroscopy (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS), flame or furnace atomic absorption spectroscopy (AA or GFAA), x-ray fluorescence spectroscopy (XRF), and other techniques for elemental analysis.