STRAP GREY38 REPLACEMENT 1 * 1 PAIR
Supplier: SCHURR SCHUHVERTRIEB
STRAP GREY38 REPLACEMENT 1 * 1 PAIR
Expand 1 Items
Gastight® 1000 series syringes
Supplier: HAMILTON BONADUZ
The 1000 series is a mid volume Gastight® syringe. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision machined PTFE plunger tip which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is particularly useful with heterogeneous samples as it reduces the chance that a deposit will occur and cause the plunger to freeze.
Expand 1 Items
VWR® Professional Magnetic Hotplate Stirrers
Supplier: VWR Collection
Designed for applications requiring exceptional accuracy, stability, and repeatability these magnetic hotplate stirrers are equipped with superior heating and mixing capabilities. With temperature ranges up to 500 °C and stirring speeds reaching 1600 rpm, the VWR® magnetic hotplate stirrers are equipped to handle any research, academic and industrial application. Available in two sizes.
Expand 4 Items
Mayer’s Hemotoxylin Stain, modified. Modified for enhanced shelf-life while avoiding use of Chloral Hydrate. null
Supplier: G-Biosciences
Mayer’s Hemotoxylin Stain, modified. Modified for enhanced shelf-life while avoiding use of Chloral Hydrate. null
Expand 1 Items
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Supplier: Abnova
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Expand 1 Items
Conventional stain used for Hematoxylin and Eosin (H&E) staining in histology and cytology procedures. Ready-to-use formulation opt imized for histology and cytology procedures where reproducible results are important. null
Supplier: G-Biosciences
Conventional stain used for Hematoxylin and Eosin (H&E) staining in histology and cytology procedures. Ready-to-use formulation opt imized for histology and cytology procedures where reproducible results are important. null
Expand 1 Items
Gastight® 1700 series syringes
Supplier: HAMILTON BONADUZ
These syringes are the Gastight® version of the original 700 series syringes and are ideal for dispensing volumes from 1 µl up to 500 µl.
Expand 1 Items
LOW SHOE MARTINA S2 BLACK 37 1 * 1 PAIR
Supplier: SCHURR SCHUHVERTRIEB
LOW SHOE MARTINA S2 BLACK 37 1 * 1 PAIR
Expand 1 Items
2ml Autoanalyser Sample Cups for Hitachi Analysers (Polystyrene) 38x17mm 1 * 5.000 items
Supplier: SARSTEDT
2ml Autoanalyser Sample Cups for Hitachi Analysers (Polystyrene) 38x17mm 1 * 5.000 items
Expand 1 Items
SAFETY SHOE BLACK : SIZE 38NÜRNBERG 1 * 1 PAIR
Supplier: SCHURR SCHUHVERTRIEB
SAFETY SHOE BLACK : SIZE 38NÜRNBERG 1 * 1 PAIR
Expand 1 Items
Drawer unit 38,380x520x260 1 * 1 items
Supplier: TRESTON
Drawer unit 38,380x520x260 1 * 1 items
Expand 1 Items
BRD4 bromodomain 1 TR-FRET Assay Kit (384 wells) 1 * 1 items
Supplier: Cayman Chemical
BRD4 bromodomain 1 TR-FRET Assay Kit (384 wells) 1 * 1 items
Expand 1 Items
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Supplier: Abnova
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Expand 1 Items
Mouse monoclonal antibody raised against partial recombinant rat Grin2a. 1 * 100 µG
Supplier: Abnova
Mouse monoclonal antibody raised against partial recombinant rat Grin2a. 1 * 100 µG
Expand 1 Items
Mouse monoclonal antibody raised against partial recombinant rat Grin2a. 1 * 100 µG
Supplier: Abnova
Mouse monoclonal antibody raised against partial recombinant rat Grin2a. 1 * 100 µG
Expand 1 Items
SHOE TXL PIONNER S3 EU38 /UK 5 1 * 1 PAIR
Supplier: HONEYWELL SAFETY
SHOE TXL PIONNER S3 EU38 /UK 5 1 * 1 PAIR
Expand 1 Items
Drawer unit 38,380x520x260 1 * 1 items
Supplier: TRESTON
Drawer unit 38,380x520x260 1 * 1 items
Expand 1 Items
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Supplier: Abnova
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Expand 1 Items
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Supplier: Abnova
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Expand 1 Items
Mouse monoclonal antibody raised against partial recombinant rat Grin2a. 1 * 100 µG
Supplier: Abnova
Mouse monoclonal antibody raised against partial recombinant rat Grin2a. 1 * 100 µG
Expand 1 Items
SHOE TXL EXPLORER RIPPER S3 EU38/UK 5 1 * 1 PAIR
Supplier: HONEYWELL SAFETY
SHOE TXL EXPLORER RIPPER S3 EU38/UK 5 1 * 1 PAIR
Expand 1 Items
Water purification systems, Direct-Q® 5 UV, Direct-Q® 8 UV, Millipore®
Supplier: Merck
The Direct-Q® range of systems provides the user with a convenient and flexible solution for pure and ultrapure water requirements, directly from potable tap water. The user will have access to ultrapure water for critical applications, and pure water for less critical applications such as general glassware washing or final rinsing from the same system. The high quality ultrapure water produced by Direct-Q® systems is suitable for applications such as production of mobile phase for chromatographic separations; preparation of blanks and standard solutions for spectrophotometry, spectroscopy or other analytical techniques; and preparation of buffers for biochemical experiments. For the production of type I and type III water.
Expand 1 Items
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Supplier: Abnova
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Expand 1 Items
Mouse MAB raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Supplier: Abnova
Mouse MAB raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Expand 1 Items
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Supplier: Abnova
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Expand 1 Items
Mouse monoclonal antibody raised against partial recombinant rat Grin2a. 1 * 100 µG
Supplier: Abnova
Mouse monoclonal antibody raised against partial recombinant rat Grin2a. 1 * 100 µG
Expand 1 Items
Mouse MAB raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Supplier: Abnova
Mouse MAB raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Expand 1 Items
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG
Supplier: Abnova
Mouse monoclonal antibody raised against synthetic peptide of human SLC18A3. 1 * 100 µG