Multi-parameter meter (pH/ISE/conductivity/oxygen), bench top, Orion™ Versa Star Pro™

Supplier:   Thermo Orion
Multi-parameter meter (pH/ISE/conductivity/oxygen), bench top, Orion™ Versa Star Pro™
Supplier:  Thermo Orion
Certificates
Multi-parameter meter (pH/ISE/conductivity/oxygen), bench top, Orion™ Versa Star Pro™

4 Options Available Below

Product Details & Documents

These bench top meters with pH/ISE, conductivity and Dissolved Oxygen/RDO modules meet the most challenging applications for pH, ion concentration, conductivity, dissolved oxygen and temperature. The meters offer interchangeable measurement modules that allow multiple users to customise four separate channels to meet their specific requirements.

  • Colour display with adjustable text sizes; numeric keypad; onscreen measurement stability indicator
  • Auto-Read to hold a stable reading; ten password-protected methods per channel
  • Audible alarms automatically notify users when a set offset value, high/low limit value, and calibration time interval are reached
  • Uniformly mix solutions using up to two meter-controlled stirrer probes that are easy to position and can be quickly rinsed between samples
  • Data log collects and date/time stamps up to 2000 measurement sets with optional electrode ID, sample ID and account ID
  • Calibration log stores ten most recent calibrations per parameter with viewable graph for multipoint pH and ISE calibrations
  • Meter facilitates data transfers to a computer via USB or RS232 connections

IP 54-rated housing resists dust and splashes and can be wall-mounted if table space is limited.

When used in conjunction with the Orion Navigator Pro software, the Orion Versa Star Pro meter is designed to create electronic data records and audit trails with password-protection, which can be used to assist with 21 CFR Part 11 requirements when paired with each laboratory’s proper IT protocols, SOPs and training records.*Orion Navigator Pro software offers multi-level system access for an administrator and up to 10 users. The system administrator can customize each user’s access level from full system access to basic data collection only. The Navigator Pro software controls all meter functions including meter settings, calibration, measurement, and reporting to help ensure data integrity and provide a complete audit trail.

Features and benefits
- Generates electronic records and signatures
- Creates audit trail report for electronic records
- Limits access to authorized individuals
- Password protection with system administrator and up to 10 users
- Full computer control of meter functions including setup, calibration and measurement
- Paperless record keeping system

 : All meters are supplied with one or two VSTAR-ISE pH/ISE modules, one VSTAR-CND conductivity module, one VSTAR-RD RDO/DO module, electrode stand, universal power adapter, USB cable, literature CD, printed quick start guide, computer interface cable and meter test certificate.
Kits additionally include: 8157BNUMD ROSS Ultra Triode epoxy-body pH/ATC electrode, 013005MD Orion DuraProbe 4-cell (K=0,475) conductivity sensor, 083005MD Orion polarographic dissolved oxygen sensor, 096019 Orion Star stirrer probe, 810199 ROSS pH buffer and solution kit, 011007 Orion 1413 µS conductivity standard, 080513 DO maintenance kit, BOD adapter/funnel/stirrer.

 : * It is the responsibility of each laboratory to validate the Navigator Pro computer software for its intended use, including all regulatory requirements.

Specifications for Product Family

Specifications

  • Catalog No:
  • ORIOVSTAR90
  • ORIOVSTAR91
  • ORIOVSTAR92
  • ORIOVSTAR93
  • Model:
  • Orion™ Versa Star Pro™
  • Orion™ Versa Star Pro™
  • Orion™ Versa Star Pro™
  • Orion™ Versa Star Pro™
  • pH range:
  • −2000...+20000
  • −2000...+20000
  • −2000...+20000
  • −2000...+20000
  • pH resolution:
  • 0,1/0,01/0,001
  • 0,1/0,01/0,001
  • 0,1/0,01/0,001
  • 0,1/0,01/0,001
  • pH accuracy:
  • ±0,002
  • ±0,002
  • ±0,002
  • ±0,002
  • pH calibration:
  • Up to 6 points
  • Up to 6 points
  • Up to 6 points
  • Up to 6 points
  • mV range:
  • ±2000,0
  • ±2000,0
  • ±2000,0
  • ±2000,0
  • mV resolution:
  • 0,1
  • 0,1
  • 0,1
  • 0,1
  • mV accuracy:
  • ±0,2 or 0,05% of reading (whichever is greater)
  • ±0,2 or 0,05% of reading (whichever is greater)
  • ±0,2 or 0,05% of reading (whichever is greater)
  • ±0,2 or 0,05% of reading (whichever is greater)
  • mV calibration:
  • 1 point
  • 1 point
  • 1 point
  • 1 point
  • ISE range:
  • 0,0001 - 19990 ppm
  • 0,0001 - 19990 ppm
  • 0,0001 - 19990 ppm
  • 0,0001 - 19990 ppm
  • ISE resolution:
  • 0,0001 minimum, 1 to 4 significant digits (user selectable)
  • 0,0001 minimum, 1 to 4 significant digits (user selectable)
  • 0,0001 minimum, 1 to 4 significant digits (user selectable)
  • 0,0001 minimum, 1 to 4 significant digits (user selectable)
  • ISE accuracy:
  • ±0,2 mV or ±0,05% of reading (whichever is greater)
  • ±0,2 mV or ±0,05% of reading (whichever is greater)
  • ±0,2 mV or ±0,05% of reading (whichever is greater)
  • ±0,2 mV or ±0,05% of reading (whichever is greater)
  • ISE calibration:
  • Up to 6 points
  • Up to 6 points
  • Up to 6 points
  • Up to 6 points
  • ISE units:
  • ppm, Molar, mg/L, %, ppb or none
  • ppm, Molar, mg/L, %, ppb or none
  • ppm, Molar, mg/L, %, ppb or none
  • ppm, Molar, mg/L, %, ppb or none
  • Conductivity range:
  • 0,001 µS/cm - 3000 mS/cm
  • 0,001 µS/cm - 3000 mS/cm
  • 0,001 µS/cm - 3000 mS/cm
  • 0,001 µS/cm - 3000 mS/cm
  • Conductivity resolution:
  • 0,001 μS minimum, auto ranging up to 4 significant digits
  • 0,001 μS minimum, auto ranging up to 4 significant digits
  • 0,001 μS minimum, auto ranging up to 4 significant digits
  • 0,001 μS minimum, auto ranging up to 4 significant digits
  • Conductivity accuracy:
  • 0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
  • 0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
  • 0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
  • 0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
  • Conductivity cell constant:
  • 0,001 - 199,9 cm⁻¹
  • 0,001 - 199,9 cm⁻¹
  • 0,001 - 199,9 cm⁻¹
  • 0,001 - 199,9 cm⁻¹
  • Conductivity calibration:
  • Up to 6 points
  • Up to 6 points
  • Up to 6 points
  • Up to 6 points
  • Resistivity range:
  • 2 Ω/cm - 100,0 MΩ/cm
  • 2 Ω/cm - 100,0 MΩ/cm
  • 2 Ω/cm - 100,0 MΩ/cm
  • 2 Ω/cm - 100,0 MΩ/cm
  • Resistivity accuracy:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • Resistivity resolution:
  • 1 Ω/cm/0,1 MΩ/cm
  • 1 Ω/cm/0,1 MΩ/cm
  • 1 Ω/cm/0,1 MΩ/cm
  • 1 Ω/cm/0,1 MΩ/cm
  • Salinity range:
  • 0,06 - 80,00 psu/0,05 - 42,00 ppt
  • 0,06 - 80,00 psu/0,05 - 42,00 ppt
  • 0,06 - 80,00 psu/0,05 - 42,00 ppt
  • 0,06 - 80,00 psu/0,05 - 42,00 ppt
  • Salinity resolution:
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • Salinity accuracy:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • TDS range:
  • 0,001 - 200,0 ppm
  • 0,001 - 200,0 ppm
  • 0,001 - 200,0 ppm
  • 0,001 - 200,0 ppm
  • TDS resolution:
  • 0,001 ppm minimum, auto ranging up to 4 significant digits
  • 0,001 ppm minimum, auto ranging up to 4 significant digits
  • 0,001 ppm minimum, auto ranging up to 4 significant digits
  • 0,001 ppm minimum, auto ranging up to 4 significant digits
  • TDS accuracy:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • TDS conversion factor:
  • Linear (0,02 - 9,99)
  • Linear (0,02 - 9,99)
  • Linear (0,02 - 9,99)
  • Linear (0,02 - 9,99)
  • DO concentration:
  • DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
  • DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
  • DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
  • DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
  • DO concentration resolution:
  • 0,01/0,1 mg/L
  • 0,01/0,1 mg/L
  • 0,01/0,1 mg/L
  • 0,01/0,1 mg/L
  • DO saturation:
  • 0,0 - 600,0 %
  • 0,0 - 600,0 %
  • 0,0 - 600,0 %
  • 0,0 - 600,0 %
  • DO accuracy:
  • DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
    RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
    ±2 % saturation or ±2% of reading whichever is greater
  • DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
    RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
    ±2 % saturation or ±2% of reading whichever is greater
  • DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
    RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
    ±2 % saturation or ±2% of reading whichever is greater
  • DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
    RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
    ±2 % saturation or ±2% of reading whichever is greater
  • DO barometric pressure range:
  • 400 - 850 mmHg
  • 400 - 850 mmHg
  • 400 - 850 mmHg
  • 400 - 850 mmHg
  • Temperature range:
  • −5,0...+105,0 °C
  • −5,0...+105,0 °C
  • −5,0...+105,0 °C
  • −5,0...+105,0 °C
  • Temperature resolution:
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • Temperature accuracy:
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • Temperature calibration:
  • 1 point offset
  • 1 point offset
  • 1 point offset
  • 1 point offset
  • Temperature compensation:
  • Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
  • Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
  • Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
  • Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
  • Display:
  • Colour graphic LCD with backlight
  • Colour graphic LCD with backlight
  • Colour graphic LCD with backlight
  • Colour graphic LCD with backlight
  • Power supply:
  • Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
  • Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
  • Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
  • Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
  • Compliance:
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • Operating temperature range:
  • 5...45 °C (ambient)
  • 5...45 °C (ambient)
  • 5...45 °C (ambient)
  • 5...45 °C (ambient)
  • Data logging - log function:
  • Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
  • Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
  • Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
  • Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
  • Data logging capacity:
  • 2000 points
  • 2000 points
  • 2000 points
  • 2000 points
  • Languages:
  • English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
  • English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
  • English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
  • English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
  • Connections:
  • BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
  • BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
  • BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
  • BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
  • Outputs:
  • RS232, USB (2)
  • RS232, USB (2)
  • RS232, USB (2)
  • RS232, USB (2)
  • No. of channels:
  • 4 - customisable with modules
  • 4 - customisable with modules
  • 4 - customisable with modules
  • 4 - customisable with modules
  • Calibration:
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
  • Calibration points:
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • W×D×H:
  • 280×240×100 mm
  • 280×240×100 mm
  • 280×240×100 mm
  • 280×240×100 mm
  • Weight:
  • 1,2 kg (modules add 0,2 kg each)
  • 1,2 kg (modules add 0,2 kg each)
  • 1,2 kg (modules add 0,2 kg each)
  • 1,2 kg (modules add 0,2 kg each)

Specifications

Product Family Options

Product Information

  • Availability
    Price
  • ORIOVSTAR90
    Multi-parameter meter, bench top, Orion™ Versa Star™ Pro™ meter, with 1 × pH/ISE, 1 × conductivity and 1 × RDO/DO module (without electrodes)
    Multi-parameter meter, bench top, Orion™ Versa Star™ Pro™ meter, with 1 × pH/ISE, 1 × conductivity and 1 × RDO/DO module (without electrodes)
    Log in for availability
    Log in for availability
    1 * 1 items
    1 * 1 items - £4,630.00
    £4,630.00
    1 * 1 items
       £4,630.00

    Specifications:
    More
    Specifications
    Cat. No.
    ORIOVSTAR90
    Model
    Orion™ Versa Star Pro™
    pH range
    −2000...+20000
    pH resolution
    0,1/0,01/0,001
    pH accuracy
    ±0,002
    pH calibration
    Up to 6 points
    mV range
    ±2000,0
    mV resolution
    0,1
    mV accuracy
    ±0,2 or 0,05% of reading (whichever is greater)
    mV calibration
    1 point
    ISE range
    0,0001 - 19990 ppm
    ISE resolution
    0,0001 minimum, 1 to 4 significant digits (user selectable)
    ISE accuracy
    ±0,2 mV or ±0,05% of reading (whichever is greater)
    ISE calibration
    Up to 6 points
    ISE units
    ppm, Molar, mg/L, %, ppb or none
    Conductivity range
    0,001 µS/cm - 3000 mS/cm
    Conductivity resolution
    0,001 μS minimum, auto ranging up to 4 significant digits
    Conductivity accuracy
    0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
    Conductivity cell constant
    0,001 - 199,9 cm⁻¹
    Conductivity calibration
    Up to 6 points
    Resistivity range
    2 Ω/cm - 100,0 MΩ/cm
    Resistivity accuracy
    0,5% of reading ±1 digit
    Resistivity resolution
    1 Ω/cm/0,1 MΩ/cm
    Salinity range
    0,06 - 80,00 psu/0,05 - 42,00 ppt
    Salinity resolution
    0,01 psu or 0,01 ppt minimum, auto ranging
    Salinity accuracy
    0,5% of reading ±1 digit
    TDS range
    0,001 - 200,0 ppm
    TDS resolution
    0,001 ppm minimum, auto ranging up to 4 significant digits
    TDS accuracy
    0,5% of reading ±1 digit
    TDS conversion factor
    Linear (0,02 - 9,99)
    DO concentration
    DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
    DO concentration resolution
    0,01/0,1 mg/L
    DO saturation
    0,0 - 600,0 %
    DO accuracy
    DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
    RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
    ±2 % saturation or ±2% of reading whichever is greater
    DO barometric pressure range
    400 - 850 mmHg
    Temperature range
    −5,0...+105,0 °C
    Temperature resolution
    0,1 °C
    Temperature accuracy
    ±0,1 °C
    Temperature calibration
    1 point offset
    Temperature compensation
    Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
    Display
    Colour graphic LCD with backlight
    Power supply
    Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
    Compliance
    IP 54
    Operating temperature range
    5...45 °C (ambient)
    Data logging - log function
    Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
    Data logging capacity
    2000 points
    Languages
    English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
    Connections
    BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
    Outputs
    RS232, USB (2)
    No. of channels
    4 - customisable with modules
    Calibration
    pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
    Calibration points
    1 point relative mV (RmV) mode, 1 point ORP mode
    W×D×H
    280×240×100 mm
    Weight
    1,2 kg (modules add 0,2 kg each)
  • ORIOVSTAR91
    Multi-parameter meter, bench top, Orion™ Versa Star™ Pro™ meter, with 2 × pH/ISE, 1 × conductivity and 1 × RDO/DO module (without electrodes)
    Multi-parameter meter, bench top, Orion™ Versa Star™ Pro™ meter, with 2 × pH/ISE, 1 × conductivity and 1 × RDO/DO module (without electrodes)
    Log in for availability
    Log in for availability
    1 * 1 items
    1 * 1 items - £5,750.00
    £5,750.00
    1 * 1 items
       £5,750.00

    Specifications:
    More
    Specifications
    Cat. No.
    ORIOVSTAR91
    Model
    Orion™ Versa Star Pro™
    pH range
    −2000...+20000
    pH resolution
    0,1/0,01/0,001
    pH accuracy
    ±0,002
    pH calibration
    Up to 6 points
    mV range
    ±2000,0
    mV resolution
    0,1
    mV accuracy
    ±0,2 or 0,05% of reading (whichever is greater)
    mV calibration
    1 point
    ISE range
    0,0001 - 19990 ppm
    ISE resolution
    0,0001 minimum, 1 to 4 significant digits (user selectable)
    ISE accuracy
    ±0,2 mV or ±0,05% of reading (whichever is greater)
    ISE calibration
    Up to 6 points
    ISE units
    ppm, Molar, mg/L, %, ppb or none
    Conductivity range
    0,001 µS/cm - 3000 mS/cm
    Conductivity resolution
    0,001 μS minimum, auto ranging up to 4 significant digits
    Conductivity accuracy
    0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
    Conductivity cell constant
    0,001 - 199,9 cm⁻¹
    Conductivity calibration
    Up to 6 points
    Resistivity range
    2 Ω/cm - 100,0 MΩ/cm
    Resistivity accuracy
    0,5% of reading ±1 digit
    Resistivity resolution
    1 Ω/cm/0,1 MΩ/cm
    Salinity range
    0,06 - 80,00 psu/0,05 - 42,00 ppt
    Salinity resolution
    0,01 psu or 0,01 ppt minimum, auto ranging
    Salinity accuracy
    0,5% of reading ±1 digit
    TDS range
    0,001 - 200,0 ppm
    TDS resolution
    0,001 ppm minimum, auto ranging up to 4 significant digits
    TDS accuracy
    0,5% of reading ±1 digit
    TDS conversion factor
    Linear (0,02 - 9,99)
    DO concentration
    DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
    DO concentration resolution
    0,01/0,1 mg/L
    DO saturation
    0,0 - 600,0 %
    DO accuracy
    DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
    RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
    ±2 % saturation or ±2% of reading whichever is greater
    DO barometric pressure range
    400 - 850 mmHg
    Temperature range
    −5,0...+105,0 °C
    Temperature resolution
    0,1 °C
    Temperature accuracy
    ±0,1 °C
    Temperature calibration
    1 point offset
    Temperature compensation
    Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
    Display
    Colour graphic LCD with backlight
    Power supply
    Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
    Compliance
    IP 54
    Operating temperature range
    5...45 °C (ambient)
    Data logging - log function
    Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
    Data logging capacity
    2000 points
    Languages
    English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
    Connections
    BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
    Outputs
    RS232, USB (2)
    No. of channels
    4 - customisable with modules
    Calibration
    pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
    Calibration points
    1 point relative mV (RmV) mode, 1 point ORP mode
    W×D×H
    280×240×100 mm
    Weight
    1,2 kg (modules add 0,2 kg each)
  • ORIOVSTAR92
    Multi-parameter meter, bench top, Orion™ Versa Star™ Pro™ kit, with 1 × pH/ISE, 1 × conductivity and 1 × RDO/DO module
    Multi-parameter meter, bench top, Orion™ Versa Star™ Pro™ kit, with 1 × pH/ISE, 1 × conductivity and 1 × RDO/DO module
    Log in for availability
    Log in for availability
    1 * 1 items
    1 * 1 items - £5,840.00
    £5,840.00
    1 * 1 items
       £5,840.00

    Specifications:
    More
    Specifications
    Cat. No.
    ORIOVSTAR92
    Model
    Orion™ Versa Star Pro™
    pH range
    −2000...+20000
    pH resolution
    0,1/0,01/0,001
    pH accuracy
    ±0,002
    pH calibration
    Up to 6 points
    mV range
    ±2000,0
    mV resolution
    0,1
    mV accuracy
    ±0,2 or 0,05% of reading (whichever is greater)
    mV calibration
    1 point
    ISE range
    0,0001 - 19990 ppm
    ISE resolution
    0,0001 minimum, 1 to 4 significant digits (user selectable)
    ISE accuracy
    ±0,2 mV or ±0,05% of reading (whichever is greater)
    ISE calibration
    Up to 6 points
    ISE units
    ppm, Molar, mg/L, %, ppb or none
    Conductivity range
    0,001 µS/cm - 3000 mS/cm
    Conductivity resolution
    0,001 μS minimum, auto ranging up to 4 significant digits
    Conductivity accuracy
    0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
    Conductivity cell constant
    0,001 - 199,9 cm⁻¹
    Conductivity calibration
    Up to 6 points
    Resistivity range
    2 Ω/cm - 100,0 MΩ/cm
    Resistivity accuracy
    0,5% of reading ±1 digit
    Resistivity resolution
    1 Ω/cm/0,1 MΩ/cm
    Salinity range
    0,06 - 80,00 psu/0,05 - 42,00 ppt
    Salinity resolution
    0,01 psu or 0,01 ppt minimum, auto ranging
    Salinity accuracy
    0,5% of reading ±1 digit
    TDS range
    0,001 - 200,0 ppm
    TDS resolution
    0,001 ppm minimum, auto ranging up to 4 significant digits
    TDS accuracy
    0,5% of reading ±1 digit
    TDS conversion factor
    Linear (0,02 - 9,99)
    DO concentration
    DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
    DO concentration resolution
    0,01/0,1 mg/L
    DO saturation
    0,0 - 600,0 %
    DO accuracy
    DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
    RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
    ±2 % saturation or ±2% of reading whichever is greater
    DO barometric pressure range
    400 - 850 mmHg
    Temperature range
    −5,0...+105,0 °C
    Temperature resolution
    0,1 °C
    Temperature accuracy
    ±0,1 °C
    Temperature calibration
    1 point offset
    Temperature compensation
    Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
    Display
    Colour graphic LCD with backlight
    Power supply
    Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
    Compliance
    IP 54
    Operating temperature range
    5...45 °C (ambient)
    Data logging - log function
    Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
    Data logging capacity
    2000 points
    Languages
    English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
    Connections
    BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
    Outputs
    RS232, USB (2)
    No. of channels
    4 - customisable with modules
    Calibration
    pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
    Calibration points
    1 point relative mV (RmV) mode, 1 point ORP mode
    W×D×H
    280×240×100 mm
    Weight
    1,2 kg (modules add 0,2 kg each)
  • ORIOVSTAR93
    Multi-parameter meter, bench top, Orion™ Versa Star™ Pro™ kit, with 2 × pH/ISE, 1 × conductivity and 1 × RDO/DO module
    Multi-parameter meter, bench top, Orion™ Versa Star™ Pro™ kit, with 2 × pH/ISE, 1 × conductivity and 1 × RDO/DO module
    Log in for availability
    Log in for availability
    1 * 1 items
    1 * 1 items - £7,050.00
    £7,050.00
    1 * 1 items
       £7,050.00

    Specifications:
    More
    Specifications
    Cat. No.
    ORIOVSTAR93
    Model
    Orion™ Versa Star Pro™
    pH range
    −2000...+20000
    pH resolution
    0,1/0,01/0,001
    pH accuracy
    ±0,002
    pH calibration
    Up to 6 points
    mV range
    ±2000,0
    mV resolution
    0,1
    mV accuracy
    ±0,2 or 0,05% of reading (whichever is greater)
    mV calibration
    1 point
    ISE range
    0,0001 - 19990 ppm
    ISE resolution
    0,0001 minimum, 1 to 4 significant digits (user selectable)
    ISE accuracy
    ±0,2 mV or ±0,05% of reading (whichever is greater)
    ISE calibration
    Up to 6 points
    ISE units
    ppm, Molar, mg/L, %, ppb or none
    Conductivity range
    0,001 µS/cm - 3000 mS/cm
    Conductivity resolution
    0,001 μS minimum, auto ranging up to 4 significant digits
    Conductivity accuracy
    0,5% of reading ±1 digit (> 3 μS); 0,5% of reading ±0,01 μS (≤ 3 μS)
    Conductivity cell constant
    0,001 - 199,9 cm⁻¹
    Conductivity calibration
    Up to 6 points
    Resistivity range
    2 Ω/cm - 100,0 MΩ/cm
    Resistivity accuracy
    0,5% of reading ±1 digit
    Resistivity resolution
    1 Ω/cm/0,1 MΩ/cm
    Salinity range
    0,06 - 80,00 psu/0,05 - 42,00 ppt
    Salinity resolution
    0,01 psu or 0,01 ppt minimum, auto ranging
    Salinity accuracy
    0,5% of reading ±1 digit
    TDS range
    0,001 - 200,0 ppm
    TDS resolution
    0,001 ppm minimum, auto ranging up to 4 significant digits
    TDS accuracy
    0,5% of reading ±1 digit
    TDS conversion factor
    Linear (0,02 - 9,99)
    DO concentration
    DO: 0,00 - 90,00 mg/L; RDO: 0,00 - 50,00 mg/L
    DO concentration resolution
    0,01/0,1 mg/L
    DO saturation
    0,0 - 600,0 %
    DO accuracy
    DO: ±0,2 mg/l or ±2% of reading (whichever is greater)
    RDO: ±0,1 mg/l (up to 8 mg/l), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
    ±2 % saturation or ±2% of reading whichever is greater
    DO barometric pressure range
    400 - 850 mmHg
    Temperature range
    −5,0...+105,0 °C
    Temperature resolution
    0,1 °C
    Temperature accuracy
    ±0,1 °C
    Temperature calibration
    1 point offset
    Temperature compensation
    Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off
    Display
    Colour graphic LCD with backlight
    Power supply
    Universal AC adapter, 100 - 240 VAC, 0 - 60 Hz,
    Compliance
    IP 54
    Operating temperature range
    5...45 °C (ambient)
    Data logging - log function
    Automatic data logging with Auto-Read, Timed and Single Shot measure modes; manual data logging with Continuous measure mode
    Data logging capacity
    2000 points
    Languages
    English, Spanish, French, Italian, German, Chinese, Portuguese and Korean
    Connections
    BNC (pH or ISE), 8-pin Mini-DIN (temperature), reference pin-tip, 8-pin Mini-DIN (conductivity with temperature probe), 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), 2 stirrer inputs
    Outputs
    RS232, USB (2)
    No. of channels
    4 - customisable with modules
    Calibration
    pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
    Calibration points
    1 point relative mV (RmV) mode, 1 point ORP mode
    W×D×H
    280×240×100 mm
    Weight
    1,2 kg (modules add 0,2 kg each)

Modules

Product Information

  • Catalog #
    Description
    Availability
    Price
  • pH/mV/temperature module for Orion™ Versa Star Pro™ meters
    Log in for availability
    Log in for availability
    1 * 1 items
    1 * 1 items - £715.00
    £715.00
    1 * 1 items
       £715.00

Product Information

  • Catalog #
    Description
    Availability
    Price
  • RDO/DO/temperature module for Orion™ Versa Star Pro™ meters
    Log in for availability
    Log in for availability
    1 * 1 items
    1 * 1 items - £1,260.00
    £1,260.00
    1 * 1 items
       £1,260.00

Product Information

  • Catalog #
    Description
    Availability
    Price
  • pH/mV/ISE/temperature module for Orion™ Versa Star Pro™ meters
    Log in for availability
    Log in for availability
    1 * 1 items
    1 * 1 items - £1,310.00
    £1,310.00
    1 * 1 items
       £1,310.00

Product Information

  • Catalog #
    Description
    Availability
    Price
  • Conductivity/TDS/resistivity/salinity/temperature module for Orion™ Versa Star Pro™ meters
    Log in for availability
    Log in for availability
    1 * 1 items
    1 * 1 items - £1,260.00
    £1,260.00
    1 * 1 items
       £1,260.00

Product Information

  • Catalog #
    Description
    Availability
    Price
  • pH/LogR/mV/RmV/ORP/temperature module for Orion™ Versa Star Pro™ meters (LogR technology uses the glass-bulb of most pH electrodes to measure both pH and temperature at the same location)
    Log in for availability
    Log in for availability
    1 * 1 items
    1 * 1 items - £1,180.00
    £1,180.00
    1 * 1 items
       £1,180.00

Services

Product Information

  • Catalog #
    Description
    Availability
    Price
  • ORIOIQOQ-VSTAR
    IQ/OQ documentation for Orion™ Versa Star meters
    Log in for availability
    1 * 1 items - £462.00

Accessories

Product Information

  • Catalog #
    Availability
    Price
  • Universal power adapter for Orion™ Versa Star™ meters, with US, EU, UK and China plug, 90 - 260 VAC, 50/60 Hz
    Universal power adapter for Orion™ Versa Star™ meters, with US, EU, UK and China plug, 90 - 260 VAC, 50/60 Hz
    ORIOSTARA-PWR
    Log in for availability
    1 * 1 items - £86.50