Easily create, modify and access programs, saving time.
- Flexible—your choice of one, two, or four block capacities in 96-well, 384-well, or mixed formats
- Independently control each block for simplified temperature and space optimization
- Software allows quick access to commonly used protocols
These compact thermal cyclers deliver reproducible results every run—with little to no training needed. Features include a clear responsive touch screen, secure user-specific programming, adjustable heated lid, and active sample cooling for sharper amplification.
A Program Wizard generates a protocol specific to your sequence in seconds—a quick way to optimise new assays. Units also retain approximately 1000 reports for reviewing at a later date and run on an intuitive, HD Android™ tablet interface. Save your personal settings to your USB drive; sign in is as simple as inserting your USB drive, no password needed.
To order chemicals, medical devices, or other restricted products please provide ID that includes your business name & shipping address via email [email protected] or fax 484.881.5997 referencing your VWR account number. Acceptable forms of ID are:
- • State issued document with your organization's Federal Tax ID Number
- • State issued document with your organization's Resale Tax ID Number
- • City or County issued Business License
- • State Department of Health Services License
- • Any other ID issued by the State that includes the business name & address
* ATTN: California Customers may require additional documentation as part of the CA Health & Safety Code. Products that fall under this regulation will be placed on a mandatory 21-day hold after documentation is received. Avantor will not lift restrictions for residential shipping addresses.
- Catalog No:
- TECN93945-20
- TECN93945-10
- TECN93945-12
- TECN93945-04
- TECN93945-06
- TECN93945-08
- TECN93945-22
- TECN93945-00
- TECN93945-28
- Block homogeneity:
- ±0,3 at 55 °C
- ±0,3 at 55 °C
- ±0,3 at 55 °C
- ±0,3 at 55 °C
- ±0,3 at 55 °C
- ±0,3 at 55 °C
- ±0,3 at 55 °C
- ±0,3 at 55 °C
- ±0,3 at 55 °C
- Gradient:
- +
- +
- +
- +
- +
- +
- +
- +
- +
- Gradient temperature range:
- 1...29 °C
- 1...29 °C
- 1...29 °C
- 1...29 °C
- 1...29 °C
- 1...29 °C
- 1...29 °C
- 1...29 °C
- 1...29 °C
- Heating ramp rate:
- 3,4 °C/s
- 3,4 °C/s
- 3,4 °C/s
- 3,4 °C/s
- 3,4 °C/s
- 3,4 °C/s
- 3,4 °C/s
- 3,4 °C/s
- 3,4 °C/s
- Interfaces:
- USB
- USB
- USB
- USB
- USB
- USB
- USB
- USB
- USB
- Lid temperature range:
- 35...115 °C, or off
- 35...115 °C, or off
- 35...115 °C, or off
- 35...115 °C, or off
- 35...115 °C, or off
- 35...115 °C, or off
- 35...115 °C, or off
- 35...115 °C, or off
- 35...115 °C, or off
- Programs:
- Max. 1000
- Max. 1000
- Max. 1000
- Max. 1000
- Max. 1000
- Max. 1000
- Max. 1000
- Max. 1000
- Max. 1000
- Sample capacity:
- One 384-well plate, one set of 96×0,2 ml tubes or one 96-well plate
- One 384-well plate, three sets of 96×0,2 ml tubes or three 96-well plates
- Four sets of 96×0,2 ml tubes or four 96-well plates
- Three 384-well plates, one set of 96×0,2 ml tubes or one 96-well plate
- Two 384-well plates, two sets of 96×0,2 ml tubes or two 96-well plates
- Four 384-well plates
- Two sets of 96×0,2 ml tubes or two 96-well plates
- One 384-well plate
- Two 384-well plates
- Temperature accuracy:
- ±0,25 at 50 °C
- ±0,25 at 50 °C
- ±0,25 at 50 °C
- ±0,25 at 50 °C
- ±0,25 at 50 °C
- ±0,25 at 50 °C
- ±0,25 at 50 °C
- ±0,25 at 50 °C
- ±0,25 at 50 °C
- Temperature range:
- 10...100 °C
- 10...100 °C
- 10...100 °C
- 10...100 °C
- 10...100 °C
- 10...100 °C
- 10...100 °C
- 10...100 °C
- 10...100 °C
- W×D×H:
- 470×330×535 mm
- 700×330×535 mm
- 700×330×535 mm
- 700×330×535 mm
- 700×330×535 mm
- 700×330×535 mm
- 470×330×535 mm
- 430×330×260 mm
- 470×330×535 mm