Order Entry
Northern Ireland
ContactUsLinkComponent
pH/mV/°C/ISE meter, bench, Orion™ Dual Star™
pH/mV/°C/ISE meter, bench, Orion™ Dual Star™
Supplier:  Thermo Orion
Certificates
undefined
pH/mV/°C/ISE meter, bench, Orion™ Dual Star™
Supplier:  Thermo Orion
Restricted Products: To process your orders without delay, please provide the required business documentation to purchase this product.

To order chemicals, medical devices, or other restricted products please provide ID that includes your business name & shipping address via email [email protected] or fax 484.881.5997 referencing your VWR account number. Acceptable forms of ID are:

  • • State issued document with your organization's Federal Tax ID Number
  • • State issued document with your organization's Resale Tax ID Number
  • • City or County issued Business License
  • • State Department of Health Services License
  • • Any other ID issued by the State that includes the business name & address

* ATTN: California Customers may require additional documentation as part of the CA Health & Safety Code. Products that fall under this regulation will be placed on a mandatory 21-day hold after documentation is received. Avantor will not lift restrictions for residential shipping addresses.

Specifications

  • Catalog No:
  • ORIO2115203
  • ORIO2115001
  • ORIO2115101
  • ORIO2115205
  • ORIO2115000
  • ORIO2115102
  • ORIO2115201
  • ORIO2115204
  • ORIO2115202
  • Model:
  • Dual Star™
  • Dual Star™
  • Dual Star™
  • Dual Star™
  • Dual Star™
  • Dual Star™
  • Dual Star™
  • Dual Star™
  • Dual Star™
  • pH range:
  • −2,000...+19,999
  • −2,000...+19,999
  • −2,000...+19,999
  • −2,000...+19,999
  • −2,000...+19,999
  • −2,000...+19,999
  • −2,000...+19,999
  • −2,000...+19,999
  • −2,000...+19,999
  • pH resolution:
  • 0,1, 0,01, 0,001
  • 0,1, 0,01, 0,001
  • 0,1, 0,01, 0,001
  • 0,1, 0,01, 0,001
  • 0,1, 0,01, 0,001
  • 0,1, 0,01, 0,001
  • 0,1, 0,01, 0,001
  • 0,1, 0,01, 0,001
  • 0,1, 0,01, 0,001
  • pH accuracy:
  • ±0,002
  • ±0,002
  • ±0,002
  • ±0,002
  • ±0,002
  • ±0,002
  • ±0,002
  • ±0,002
  • ±0,002
  • pH calibration:
  • 1 - 6 points with automatic buffer recognition (NIST, DIN, custom)
  • 1 - 6 points with automatic buffer recognition (NIST, DIN, custom)
  • 1 - 6 points with automatic buffer recognition (NIST, DIN, custom)
  • 1 - 6 points with automatic buffer recognition (NIST, DIN, custom)
  • 1 - 6 points with automatic buffer recognition (NIST, DIN, custom)
  • 1 - 6 points with automatic buffer recognition (NIST, DIN, custom)
  • 1 - 6 points with automatic buffer recognition (NIST, DIN, custom)
  • 1 - 6 points with automatic buffer recognition (NIST, DIN, custom)
  • 1 - 6 points with automatic buffer recognition (NIST, DIN, custom)
  • mV range:
  • ±1999,9
  • ±1999,9
  • ±1999,9
  • ±1999,9
  • ±1999,9
  • ±1999,9
  • ±1999,9
  • ±1999,9
  • ±1999,9
  • mV resolution:
  • 0,1
  • 0,1
  • 0,1
  • 0,1
  • 0,1
  • 0,1
  • 0,1
  • 0,1
  • 0,1
  • mV accuracy:
  • ±0,2 mV or ±0,05% of reading; whichever is greater
  • ±0,2 of measured value or 0,05% of reading (whichever is greater)
  • ±0,2 of measured value or 0,05% of reading (whichever is greater)
  • ±0,2 of measured value or 0,05% of reading (whichever is greater)
  • ±0,2 of measured value or 0,05% of reading (whichever is greater)
  • ±0,2 of measured value or 0,05% of reading (whichever is greater)
  • ±0,2 mV or ±0,05% of reading; whichever is greater
  • ±0,2 mV or ±0,05% of reading; whichever is greater
  • ±0,2 mV or ±0,05% of reading; whichever is greater
  • ISE range:
  • 0 - 19999
  • 0 - 19999
  • 0 - 19999
  • 0 - 19999
  • 0 - 19999
  • 0 - 19999
  • 0 - 19999
  • 0 - 19999
  • 0 - 19999
  • ISE resolution:
  • 1, 2 or 3 significant digits
  • 1, 2 or 3 significant digits
  • 1, 2 or 3 significant digits
  • 1, 2 or 3 significant digits
  • 1, 2 or 3 significant digits
  • 1, 2 or 3 significant digits
  • 1, 2 or 3 significant digits
  • 1, 2 or 3 significant digits
  • 1, 2 or 3 significant digits
  • ISE accuracy:
  • ±0,2 mV or ±0,05% of reading; whichever is greater
  • ±0,2 of measured value or 0,05%
  • ±0,2 of measured value or 0,05%
  • ±0,2 of measured value or 0,05%
  • ±0,2 of measured value or 0,05%
  • ±0,2 of measured value or 0,05%
  • ±0,2 mV or ±0,05% of reading; whichever is greater
  • ±0,2 mV or ±0,05% of reading; whichever is greater
  • ±0,2 mV or ±0,05% of reading; whichever is greater
  • ISE calibration:
  • 2 - 6 points (linear, point to point, non-linear selectable auto-blank)
  • 2 - 6 points (linear, point to point, non-linear selectable auto-blank)
  • 2 - 6 points (linear, point to point, non-linear selectable auto-blank)
  • 2 - 6 points (linear, point to point, non-linear selectable auto-blank)
  • 2 - 6 points (linear, point to point, non-linear selectable auto-blank)
  • 2 - 6 points (linear, point to point, non-linear selectable auto-blank)
  • 2 - 6 points (linear, point to point, non-linear selectable auto-blank)
  • 2 - 6 points (linear, point to point, non-linear selectable auto-blank)
  • 2 - 6 points (linear, point to point, non-linear selectable auto-blank)
  • ISE units:
  • ppm, ppb, M, % or unitless
  • ppm, ppb, M, % or unitless
  • ppm, ppb, M, % or unitless
  • ppm, ppb, M, % or unitless
  • ppm, ppb, M, % or unitless
  • ppm, ppb, M, % or unitless
  • ppm, ppb, M, % or unitless
  • ppm, ppb, M, % or unitless
  • ppm, ppb, M, % or unitless
  • Temperature range:
  • –5...+105 °C
  • –5...+105 °C
  • –5...+105 °C
  • –5...+105 °C
  • –5...+105 °C
  • –5...+105 °C
  • –5...+105 °C
  • –5...+105 °C
  • –5...+105 °C
  • Temperature resolution:
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • 0,1 °C
  • Temperature accuracy:
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • ±0,1 °C
  • Temperature calibration:
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • Temperature compensation:
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Manual or automatic with ATC temperature probe
  • Display:
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Power supply:
  • Universal AC adapter (included)
  • Universal AC adapter (included)
  • Universal AC adapter (included)
  • Universal AC adapter (included)
  • Universal AC adapter (included)
  • Universal AC adapter (included)
  • Universal AC adapter (included)
  • Universal AC adapter (included)
  • Universal AC adapter (included)
  • Compliance:
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • Operating temperature range:
  • 5…45 °C
  • 5…45 °C
  • 5…45 °C
  • 5…45 °C
  • 5…45 °C
  • 5…45 °C
  • 5…45 °C
  • 5…45 °C
  • 5…45 °C
  • Data logging - log function:
  • Automatic data logging with auto-read, on ready, at timed intervals, value change in measurement and timed reading measure modes; manual data logging with continuous measure mode
  • Automatic data logging with auto-read, on ready, at timed intervals, value change in measurement and timed reading measure modes; manual data logging with continuous measure mode
  • Automatic data logging with auto-read, on ready, at timed intervals, value change in measurement and timed reading measure modes; manual data logging with continuous measure mode
  • Automatic data logging with auto-read, on ready, at timed intervals, value change in measurement and timed reading measure modes; manual data logging with continuous measure mode
  • Automatic data logging with auto-read, on ready, at timed intervals, value change in measurement and timed reading measure modes; manual data logging with continuous measure mode
  • Automatic data logging with auto-read, on ready, at timed intervals, value change in measurement and timed reading measure modes; manual data logging with continuous measure mode
  • Automatic data logging with auto-read, on ready, at timed intervals, value change in measurement and timed reading measure modes; manual data logging with continuous measure mode
  • Automatic data logging with auto-read, on ready, at timed intervals, value change in measurement and timed reading measure modes; manual data logging with continuous measure mode
  • Automatic data logging with auto-read, on ready, at timed intervals, value change in measurement and timed reading measure modes; manual data logging with continuous measure mode
  • Data logging capacity:
  • 1000 points with time/date stamp
  • 1000 points with time/date stamp
  • 1000 points with time/date stamp
  • 1000 points with time/date stamp
  • 1000 points with time/date stamp
  • 1000 points with time/date stamp
  • 1000 points with time/date stamp
  • 1000 points with time/date stamp
  • 1000 points with time/date stamp
  • Memory:
  • 20 methods (10 per channel with calibration data)
  • 20 methods (10 per channel with calibration data)
  • 20 methods (10 per channel with calibration data)
  • 20 methods (10 per channel with calibration data)
  • 20 methods (10 per channel with calibration data)
  • 20 methods (10 per channel with calibration data)
  • 20 methods (10 per channel with calibration data)
  • 20 methods (10 per channel with calibration data)
  • 20 methods (10 per channel with calibration data)
  • Languages:
  • English, Spanish, French, Italian, and German
  • English, Spanish, French, Italian, and German
  • English, Spanish, French, Italian, and German
  • English, Spanish, French, Italian, and German
  • English, Spanish, French, Italian, and German
  • English, Spanish, French, Italian, and German
  • English, Spanish, French, Italian, and German
  • English, Spanish, French, Italian, and German
  • English, Spanish, French, Italian, and German
  • IP rating:
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • IP 54
  • Dimensions:
  • 24L×17W×9H cm (9,5×6,7×3,5")
  • 24L×17W×9H cm (9.5×6.7×3.5")
  • 24L×17W×9H cm (9.5×6.7×3.5")
  • 24L×17W×9H cm (9,5×6,7×3,5")
  • 24L×17W×9H cm (9.5×6.7×3.5")
  • 24L×17W×9H cm (9.5×6.7×3.5")
  • 24L×17W×9H cm (9,5×6,7×3,5")
  • 24L×17W×9H cm (9,5×6,7×3,5")
  • 24L×17W×9H cm (9,5×6,7×3,5")
  • Connections:
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Outputs:
  • USB, RS232
  • USB, RS232
  • USB, RS232
  • USB, RS232
  • USB, RS232
  • USB, RS232
  • USB, RS232
  • USB, RS232
  • USB, RS232
  • Input:
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Two BNC (pH, ORP or ion selective electrode), two pin-tip (reference electrode), two 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
  • Alarm:
  • High/low limit alarm
  • High/low limit alarm
  • High/low limit alarm
  • High/low limit alarm
  • High/low limit alarm
  • High/low limit alarm
  • High/low limit alarm
  • High/low limit alarm
  • High/low limit alarm
  • Parameters:
  • pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature
  • pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature
  • pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature
  • pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature
  • pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature
  • pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature
  • pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature
  • pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature
  • pH, mV, relative mV (RmV), ORP or ion concentration (ISE) with temperature
  • Calibration:
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ.
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ.
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ.
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ.
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ.
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ.
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ.
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ.
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ.
  • Calibration points:
  • 1 point mV (RmV) mode; 1 point ORP mode; 2 - 6 points ISE mode; 1 - 6 points pH mode
  • 1 point mV (RmV) mode; 1 point ORP mode; 2 - 6 points ISE mode; 1 - 6 points pH mode
  • 1 point mV (RmV) mode; 1 point ORP mode; 2 - 6 points ISE mode; 1 - 6 points pH mode
  • 1 point mV (RmV) mode; 1 point ORP mode; 2 - 6 points ISE mode; 1 - 6 points pH mode
  • W×D×H:
  • 240×170×90 mm
  • 240×170×90 mm
  • 240×170×90 mm
  • 240×170×90 mm
  • 240×170×90 mm
  • 240×170×90 mm
  • 240×170×90 mm
  • 240×170×90 mm
  • 240×170×90 mm
  • Weight:
  • 0,9 kg
  • 0,9 kg
  • 0,9 kg
  • 0,9 kg
  • 0,9 kg
  • 0,9 kg
  • 0,9 kg
  • 0,9 kg
  • 0,9 kg

Specifications

Electrodes

Product Information

Frequently Bought Together