About this item
This rugged, waterproof portable meter is designed for a wide range of pH, mV, ORP, conductivity, total dissolved solids (TDS), salinity, resistivity and temperature testing and field applications. It can be used in the most demanding locations thanks to its IP67-rated housing. The meter offers two measuring channels allowing users to measure pH and conductivity simultaneously or view each channel separately.
- Up to a five point pH calibration using automatic buffer recognition of NIST or DIN buffer groups with choice to manually enter custom buffer values
- Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
- Easily view individual measurements on a full screen display and quickly toggle to a split screen display to view multiple measurements simultaneously
- Measurement stability indicator and selectable read modes – Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
- Data log collects and date/time stamps up to 5000 measurement sets with optional sample ID and user ID
- Calibration log stores ten most recent calibrations
- Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
Measure pH, mV, relative mV or ORP with temperature on channel one and measure conductivity, TDS, salinity or resistivity with temperature on channel two.
Auto-ranging conductivity values offer consistent readings across entire measurement range without need to recalibrate. Use linear, non linear, EP (USP) or off conductivity temperature compensation with 5, 10, 15, 20 or 25 °C reference temperatures.
The kit additionally includes: 8107UWMMD ROSS Ultra Triode gel-filled epoxy-body pH/ATC electrode (3 m cable), 013010MD DuraProbe 4-cell (K=0,475) epoxy-body conductivity sensor (3 m cable), Orion pH 4/7/10 buffer pouches (10 packs each), ROSS electrode storage solution (475 ml), Orion rinse solution pouches (10 packs), Orion 1413 µS conductivity standard pouches (10 packs), Orion Star A series portable meter armor and Orion Star A series hard-sided field case.
Specifications
- Catalog No:
- 665-0278
- 665-0277
- Model:
- A325
- A325
- pH range:
- –2,000...+20,000
- –2,000...+20,000
- pH resolution:
- 0,1 / 0,01 / 0,001
- 0,1 / 0,01 / 0,001
- pH accuracy:
- ±0,002
- ±0,002
- pH calibration:
- Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
- Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
- mV range:
- ±2000,0
- ±2000,0
- mV resolution:
- 0,1
- 0,1
- mV accuracy:
- ±0,2 mV or ±0,05% of reading, whichever is greater
- ±0,2 mV or ±0,05% of reading, whichever is greater
- Conductivity range:
- 0,001 µS/cm - 3000 mS/cm
- 0,001 µS/cm - 3000 mS/cm
- Conductivity resolution:
- 0,001 μS minimum, auto ranging, up to 4 significant digits
- 0,001 μS minimum, auto ranging, up to 4 significant digits
- Conductivity accuracy:
- ±0,5% of reading ±1 digit
- ±0,5% of reading ±1 digit
- Conductivity cell constant:
- 0.001 - 199.9cm⁻¹
- 0.001 - 199.9 cm⁻¹
- Conductivity calibration:
- Up to 5 points
- Up to 5 points
- Resistivity range:
- 2 Ω/cm - 100 MΩ/cm
- 2 Ω/cm - 100 MΩ/cm
- Resistivity accuracy:
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- Salinity range:
- 0,06 - 80,00 psu / 0,05 - 42.00 ppt
- 0,06 - 80,00 psu / 0,05 - 42.00 ppt
- Salinity resolution:
- 0,01 psu or 0,01 ppt minimum, auto ranging
- 0,01 psu or 0,01 ppt minimum, auto ranging
- Salinity accuracy:
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- TDS range:
- 0,001 - 200,0 ppm
- 0,001 - 200,0 ppm
- TDS resolution:
- 0,001 ppm minimum, auto ranging, up to 4 significant digits
- 0,001 ppm minimum, auto ranging, up to 4 significant digits
- TDS accuracy:
- 0,5% of reading ±1 digit
- 0,5% of reading ±1 digit
- TDS conversion factor:
- Linear (0,02 - 9,99)
- Linear (0,02 - 9,99)
- Temperature range:
- –5,0...+105,0 °C
- –5,0...+105,0 °C
- Temperature resolution:
- 0,1 °C
- 0,1 °C
- Temperature accuracy:
- ±0,1 °C
- ±0,1 °C
- Temperature compensation:
- Automatic or manual
- Automatic or manual
- Display:
- Graphic LCD with backlight
- Graphic LCD with backlight
- Battery type:
- 4 AA (included)
- 4 AA (included)
- Battery life:
- 800 h
- 800 h
- Power supply:
- AC adapter or 4 AA batteries
- AC adapter or 4 AA batteries
- Compliance:
- IP 67
- IP 67
- Data logging - log function:
- Manual / Automatic with AUTO-READ™
- Manual / Automatic with AUTO-READ™
- Data logging capacity:
- 5000 with date and time stamp
- 5000 with date and time stamp
- Languages:
- English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
- English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
- IP rating:
- IP 67
- IP 67
- Connections:
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe)
- BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe)
- Outputs:
- RS232, USB
- RS232, USB
- Input:
- Two measuring channels
- Two measuring channels
- Alarm:
- High/low limit alarm, calibration due alarm
- High/low limit alarm, calibration due alarm
- No. of channels:
- 2
- 2
- Calibration:
- pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op
- pH with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing op
- Calibration points:
- 1 point relative mV (RmV) mode, 1 point ORP mode
- 1 point relative mV (RmV) mode, 1 point ORP mode
- W×D×H:
- 240×100×65 mm
- 240×100×65 mm
- Weight:
- 0,5 kg
- 0,5 kg