Order Entry
Northern Ireland
ContactUsLinkComponent
 
Orion Star™ A329 Multi-Parameter Meter (pH/ISE/Conductivity/DO), Handheld
 
undefined
Orion Star™ A329 Multi-Parameter Meter (pH/ISE/Conductivity/DO), Handheld
Restricted Products: To process your orders without delay, please provide the required business documentation to purchase this product.

To order chemicals, medical devices, or other restricted products please provide ID that includes your business name & shipping address via email [email protected] or fax 484.881.5997 referencing your VWR account number. Acceptable forms of ID are:

  • • State issued document with your organization's Federal Tax ID Number
  • • State issued document with your organization's Resale Tax ID Number
  • • City or County issued Business License
  • • State Department of Health Services License
  • • Any other ID issued by the State that includes the business name & address

* ATTN: California Customers may require additional documentation as part of the CA Health & Safety Code. Products that fall under this regulation will be placed on a mandatory 21-day hold after documentation is received. Avantor will not lift restrictions for residential shipping addresses.

 
 

 

  • Catalog No:
  • 665-0282
  • 665-0281
  • Model:
  • A329
  • A329
  • pH range:
  • –2,000...+20,000
  • –2,000...+20,000
  • pH resolution:
  • 0,1 / 0,01 / 0,001
  • 0,1 / 0,01 / 0,001
  • pH accuracy:
  • ±0,002
  • ±0,002
  • pH calibration:
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • Up to 5 points; Automatic buffer recognition (USA/NIST and DIN)
  • mV range:
  • ±2000,0
  • ±2000,0
  • mV resolution:
  • 0,1
  • 0,1
  • mV accuracy:
  • ±0,2 mV or 0,05%
  • ±0,2 mV or 0,05%
  • ISE range:
  • 0,0001 - 19900
  • 0,0001 - 19900
  • ISE resolution:
  • 0,0001 minimum, 1 to 3 significant digits (user selectable)
  • 0,0001 minimum, 1 to 3 significant digits (user selectable)
  • ISE accuracy:
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • ±0,2 mV or ±0,05% of reading, whichever is greater
  • ISE calibration:
  • Up to 5 points
  • Up to 5 points
  • ISE units:
  • ppm, M, mg/l, %, ppb, none
  • ppm, M, mg/l, %, ppb, none
  • Conductivity range:
  • 0,001 µS/cm - 3000 mS/cm
  • 0,001 µS/cm - 3000 mS/cm
  • Conductivity resolution:
  • 0,001 μS minimum, auto ranging, up to 4 significant digits
  • 0,001 μS minimum, auto ranging, up to 4 significant digits
  • Conductivity accuracy:
  • ±0,5% of reading ±1 digit
  • ±0,5% of reading ±1 digit
  • Conductivity cell constant:
  • 0,001 - 199,9 cm⁻¹
  • 0,001 - 199,9 cm⁻¹
  • Conductivity calibration:
  • Up to 5 points
  • Up to 5 points
  • Conductivity reference temperature:
  • 5/10/15/20/25 °C
  • 5/10/15/20/25 °C
  • Resistivity range:
  • 2 Ω/cm - 100 MΩ/cm
  • 2 Ω/cm - 100 MΩ/cm
  • Resistivity accuracy:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • Resistivity resolution:
  • 1 ohm or 0,1 meg-ohm, auto ranging
  • 1 ohm or 0,1 meg-ohm, auto ranging
  • Salinity range:
  • 0,06 - 80,00 psu / 0,05 - 42,00 ppt
  • 0,06 - 80,00 psu / 0,05 - 42,00 ppt
  • Salinity resolution:
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • 0,01 psu or 0,01 ppt minimum, auto ranging
  • Salinity accuracy:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • TDS range:
  • 0,001 - 200,0 ppm
  • 0,001 - 200,0 ppm
  • TDS resolution:
  • 0,001 ppm minimum, auto ranging, up to 4 significant digits
  • 0,001 ppm minimum, auto ranging, up to 4 significant digits
  • TDS accuracy:
  • 0,5% of reading ±1 digit
  • 0,5% of reading ±1 digit
  • TDS conversion factor:
  • Linear (0,02 - 9,99)
  • Linear (0,02 - 9,99)
  • DO concentration:
  • 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
  • 0 - 90 mg/L (polarographic); 0 - 50 mg/L (RDO)
  • DO concentration resolution:
  • 0,1 / 0,01 mg/L
  • 0,1 / 0,01 mg/L
  • DO saturation:
  • 0 - 600 % (polarographic); 0 - 500 % (RDO)
  • 0 - 600 % (polarographic); 0 - 500 % (RDO)
  • DO accuracy:
  • Polarographic: ±0,2 mg/l or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/l (up to 8 mg/), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
  • Polarographic: ±0,2 mg/l or ±2% of reading, whichever is greater
    RDO: ±0,1 mg/l (up to 8 mg/), ±0,2 mg/l (8 - 20 mg/l), ±10% of reading (up to 50 mg/l)
  • DO calibration:
  • Water-saturated air, air saturated water, manual (Winkler) and zero point
  • Water-saturated air, air saturated water, manual (Winkler) and zero point
  • DO barometric pressure range:
  • Automatic or manual, 450 - 850 mmHg
  • Automatic or manual, 450 - 850 mmHg
  • Temperature range:
  • –5,0...+105,0 °C (–5,0...+50,0 °C with DO)
  • –5,0...+105,0 °C (–5,0...+50,0 °C with DO)
  • Temperature resolution:
  • 0,1 °C
  • 0,1 °C
  • Temperature accuracy:
  • ±0,1 °C
  • ±0,1 °C
  • Temperature calibration:
  • 1 point temperature offset calibration
  • 1 point temperature offset calibration
  • Temperature compensation:
  • Automatic or manual
  • Automatic or manual
  • Pressure range:
  • 400 - 850 mm Hg
  • 400 - 850 mm Hg
  • Pressure resolution:
  • 1 mm Hg
  • 1 mm Hg
  • Display:
  • Graphic LCD with backlight
  • Graphic LCD with backlight
  • Battery type:
  • 4 AA (included)
  • 4 AA (included)
  • Battery life:
  • 800 hours
  • 800 hours
  • Power supply:
  • AC adapter or 4 AA batteries
  • AC adapter or 4 AA batteries
  • Compliance:
  • IP 67
  • IP 67
  • Data logging - log function:
  • Manual / Automatic with AUTO-READ™
  • Manual / Automatic with AUTO-READ™
  • Data logging capacity:
  • 5000
  • 5000
  • Memory:
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Non-volatile memory preserves data log, calibration log and meter settings
  • Languages:
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
  • IP rating:
  • IP 67
  • IP 67
  • Connections:
  • BNC, pin tip, 8- and 9-pin mini-DIN
  • BNC, pin tip, 8- and 9-pin mini-DIN
  • Outputs:
  • RS232, USB
  • RS232, USB
  • Input:
  • 3 measuring channels
  • 3 measuring channels
  • Alarm:
  • High/low limit alarm, calibration due alarm
  • High/low limit alarm, calibration due alarm
  • No. of channels:
  • 3
  • 3
  • Calibration:
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
  • pH with calibration editing option, ion concentration (ISE) with calibration editing option, relativ
  • Calibration points:
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • 1 point relative mV (RmV) mode, 1 point ORP mode
  • W×D×H:
  • 60×105×240 mm
  • 60×105×240 mm
  • Weight:
  • 0,5 kg
  • 0,5 kg

 

Frequently Bought Together