You searched for: Chromatography Columns
Chromatography columns separate molecules within mixtures during gas or liquid chromatography. Filled with stationary phase compositions or chemical compounds, the prepacked options reduce the preparing time required. The vertical pieces are able to withstand extreme temperatures and pressure fluctuations experienced when the mobile phase is forced through the medium. Meet preparative and analytical laboratory procedures with the chromatography columns to separate dissimilar moving components based on individual solvent polarity, composition, and size. The right chromatography control system allows to automate the delivery of cleaning, sanitizing and conditioning buffers to the packed column, and can enable to cycle the chromatography column several times during the batch, requiring smaller columns and subsequent lower capital investment.
Strong anion exchange HPLC columns, PL-SAX
Supplier: VARIAN
These columns are ideal for the anion exchange HPLC separations of proteins and deprotected synthetic oligonucleotides under denaturing conditions.
Expand 24 Items
HPLC columns, ZORBAX® Eclipse XDB
Supplier: Agilent
Good peak shape for basic, acidic and neutral compounds.
Expand 42 Items
GC columns, J&W PoraBOND U
Supplier: VARIAN
PoraBOND U is a highly stable polar-bonded porous polymer with the maximum temperature extended from 190 to 300 °C.
Expand 2 Items
Capillary columns, CP-Carbowax 400
Supplier: VARIAN
CP-Carbowax 400 has highest resolution for amyl alcohols for accurate quality inspection.
Expand 1 Items
HPLC columns, ZORBAX® 80 Å Extend-C18
Supplier: Agilent
High sensitivity for LC/MS separations of peptides.
Expand 1 Items
High efficiency GC columns
Supplier: VARIAN
High efficiency 0,15 and 0,18 mm Int.Ø columns are a simple and cost effective way to increase sample throughput with existing GC or GC/MS instruments.
Expand 8 Items
Capillary columns, DB-624
Supplier: Agilent
These columns are recommended for EPA methods 502.2 and 8021, as well as for fast GC/MS volatiles analysis. They are specifically designed for the analysis of volatile priority pollutants and residual solvents.
Expand 4 Items
HPLC columns, ZORBAX® 300 Å Extend-C18
Supplier: Agilent
Rugged, high and low pH separations of polypeptides and peptides from pH 2 to11,5.
Expand 2 Items
Analytical HPLC columns, Microsorb™ Si
Supplier: VARIAN
Microsorb™ Silica is ideal for the separation of low molecular weight compounds that dissolve in organic solvents. Separations on silica columns depend upon the difference in orientation, type and number of functional groups associated with the compounds in the sample.
Expand 3 Items
Capillary columns, CP-Sil PONA CB
Supplier: VARIAN
CP-Sil PONA CB delivers accurate analysis of paraffins, olefins, naphthalenes and aromatics in complex hydrocarbon mixtures.
Expand 3 Items
J&W PLOT PT GC columns
Supplier: VARIAN
PLOT PT columns have an integral particle trap at each end, to eliminate the bother of connecting separate traps, and enable GC/MS with leak-free operation and no anxiety.
Expand 8 Items
HPLC/UHPLC columns, Kromasil® Classic, 100 Å
Supplier: HICHROM
The Kromasil® Classic 100 Å family of products is used to separate and purify molecules of up to 10000 Da. Drug candidates for the pharmaceutical, natural products and API industries are separated and purified using Kromasil® Classic 100 Å columns.
Expand 8 Items
HPLC columns, MetaCarb
Supplier: VARIAN
The MetaCarb™ line of carbohydrate columns provides high resolution columns for applications requiring high performance carbohydrate and organic acid analysis. These columns contain sulfonated polystyrene resins in the Calcium (87C), Hydrogen (87H), and Lead (87P) forms, and provide a wide range of selectivities for carbohydrate and organic analysis. They are widely used in the food and beverage industries for analysis of sweeteners, corn and cane sugars, fruit juices, soft drinks, beer and dairy products.
Expand 31 Items
Capillary columns, CP-Wax for volatile amines and diamines
Supplier: VARIAN
CP-Wax for volatile amines and diamines is optimised for analysis of volatile amines and diamines, particularly C3-C8 amines and diamines. The column delivers symmetrical peaks due to basic reagent deactivation and exhibits good inertness towards basic compounds.
Expand 2 Items
Solid phase extraction cartridges, Bond Elut™ C18 EWP
Supplier: VARIAN
Bond Elut™ EWP is based upon standard particle size silica but with 500 Å pores to allow more efficient extraction of large molecules (>15000 MW), which are typically excluded from standard porosity silica phases.
Expand 5 Items
Reversed phase HPLC columns, Poroshell 300
Supplier: Agilent
Poroshell 300 columns are ideal for fast separations of proteins and peptides because the superficially porous particle allows for fast flow rates to be used while maintaining sharp, efficient peaks. Peptides and proteins are typically separated slowly to reduce the potential peak broadening of these slow diffusing analytes. However, Poroshell columns use a superficially porous particle made with a thin layer of porous silica on a solid core of silica, reducing the diffusion distance for proteins making practical rapid HPLC separations of peptides and proteins up to 500 to 1000 kDa.
Expand 7 Items
Solid phase extraction cartridges, Bond Elut™ SI
Supplier: VARIAN
Native silica is generally regarded as the most polar SPE sorbent available. Bond Elut™ SI is particularly effective at separating compounds with a very similar structure. Applying the analytes in a non-polar solvent, then increasing the solvent polarity by increasing the concentration of a polar modifier, such as THF or ethyl acetate, delivers effective separations.
Expand 18 Items
Solid phase extraction cartridges, Bond Elut™ SAX
Supplier: VARIAN
Bond Elut™ SAX is a strong anion exchange sorbent ideally suited for the extraction of compounds such as carboxylic acids, which may not retain effectively on weak anion exchange sorbents. The sorbent is supplied in the chloride counter ion form. You can modify the selectivity of the phase by replacing the chloride ion with other anions, such as acetate and hydroxide.
Expand 29 Items
Solid phase extraction cartridges, Bond Elut™ NH₂
Supplier: VARIAN
Bond Elut™ NH₂ is a weaker anion exchanger than sorbents such as SAX (a quaternary amine sorbent that is always charged) and is therefore a better choice for retention of very strong anions, such as sulfonic acids, which may retain irreversibly on a SAX sorbent. Similar to Diol and SI sorbents, Bond Elut™ NH₂ is excellent for the separation of structural isomers.
Expand 24 Items
Solid phase extraction cartridges, Bond Elut™ C18 OH
Supplier: VARIAN
Bond Elut™ C18 OH is a non-end capped version of the octadecyl bonded phases that enables the silanols on the silica surface to be more active. This low-load C18 has well-controlled silanol activity that permits the fractionation of metabolites and enhances retention of basic compounds compared to an endcapped C18. The pore size makes it a good choice for peptide extraction.
Expand 4 Items
Solid phase extraction cartridges, Bond Elut™ C8
Supplier: VARIAN
Bond Elut™ C8 is very similar in properties to C18, but is not as retentive for non-polar compounds, due to its shorter hydrocarbon chain, and therefore reduced carbon loading. C8 is an excellent replacement for C18 when analytes are too strongly retained for effective elution. The potential for polar interactions is somewhat higher than for C18 because there is less coverage of the silica surface. These polar interactions are not, however, a significant property of C8.
Expand 23 Items
PLOT columns, CP-PoraPLOT Q and CP-PoraPLOT Q-HT
Supplier: VARIAN
CP-PoraPLOT Q is recommended for column switching systems that analyze polar and apolar volatile compounds.
Expand 17 Items
Capillary columns, CP-Sil™ 8CB/MS
Supplier: VARIAN
5% phenyl 95% dimethylpolysiloxane low bleed phase
Expand 5 Items
Capillary columns, Rapid-MS
Supplier: VARIAN
Rapid-MS columns reduce analysis duration by 3 to 5 times for temperature programmed, and up to 10 times for isothermal runs.
Expand 4 Items
GC columns, J&W Ultra 1
Supplier: Agilent
Agilent's non-polar Ultra 1 columns deliver excellent performance and accuracy in a range of chromatographic applications.
Expand 1 Items
Capillary columns, select permanent gases
Supplier: VARIAN
Select Permanent Gases/CO₂ is a set of two parallel columns that combines CP-Molsieve 5 Å for permanent gas analysis and CP-PoraBOND Q for CO₂ analysis.
Expand 3 Items
Capillary columns, CP-Select 624 CB
Supplier: VARIAN
The CP-Select 624 CB is a highly reproducible version of the popular 624 phase and has 2-3 times lower bleed than conventional columns.
Expand 9 Items
HPLC columns, VariTide RPC
Supplier: VARIAN
VariTide RPC column is designed for use across the pH range, making it suitable for the analysis and purification of acid or basic and hydrophilic or hydrophobic peptides, using acid, neutral and basic eluents.
Expand 5 Items
PAH columns, ZORBAX® Eclipse
Supplier: Agilent
ZORBAX® Eclipse PAH HPLC columns are the ideal first choice for method development of all samples.
Expand 1 Items
Capillary columns, VF-1301ms
Supplier: VARIAN
VF-1301ms ultra-low-bleed thin film columns have a similar selectivity to VF-624ms and are suitable for the analysis of semivolatile organic solvents, as well as PCBs and pesticides.