Masterflex® Multi-Syringe Pumps, Multi-Step, Avantor®
About this item
Ideal for low-flow, low-pressure applications where precision is needed.
- Flow ranges from 0.05 uL/min up to 70.56 ml/min
- Built-in program lets you enter up to eight commands to perform a variety of functions—you can even repeat commands up to ten times; all settings are stored in nonvolatile memory
- Backlit alphanumeric LCD ste
Program flow rate hold, pause, and change of direction; each command can be set to run for up to 12 hours. You can even program infusion/withdrawal pumps to sequence operations: either withdrawal followed by infusion or infusion followed by withdrawal. Ch
: Includes a 6-ft cord with grounded plug (U.S. standard plug on 115 VAC model and European plug on 230 VAC models).
1 Options Available Below
Product Details & Documents
Ideal for low-flow, low-pressure applications where precision is needed.
- Flow ranges from 0.05 uL/min up to 70.56 ml/min
- Built-in program lets you enter up to eight commands to perform a variety of functions—you can even repeat commands up to ten times; all settings are stored in nonvolatile memory
- Backlit alphanumeric LCD ste
Program flow rate hold, pause, and change of direction; each command can be set to run for up to 12 hours. You can even program infusion/withdrawal pumps to sequence operations: either withdrawal followed by infusion or infusion followed by withdrawal. Ch
: Includes a 6-ft cord with grounded plug (U.S. standard plug on 115 VAC model and European plug on 230 VAC models).
Specifications for Product Family
Specifications
- Catalog No:
- DUP-DO-NOT-USE 490
- DUP-DO-NOT-USE 491
- MFLX74900-65
- DUP-DO-NOT-USE 080
- DUP-DO-NOT-USE 085
- MFLX74900-85
- DUP-DO-NOT-USE 010
- MFLX74901-05
- MFLX74901-15
- Model:
- 74900-60
- 74900-65
- 74900-65
- 74900-80
- 74900-85
- 74900-85
- 74901-00
- 74901-05
- 74901-15
- Accuracy:
- ±1.0%
- ±1.0%
- ±1.0%
- ±1.0%
- ±1.0%
- ±1.0%
- ±0.5%
- ±0.5%
- ±0.5%
- Input:
- Baud rate: four settings up to 9600
- Baud rate: four settings up to 9600
- Baud rate: four settings up to 9600
- Linear force:
- 40 lbs.
- 40 lbs.
- 40 lbs.
- 40 lbs.
- 40 lbs.
- 40 lbs.
- 40 lbs.
- 40 lbs.
- 40 lbs.
- Reproducibility:
- ±0.1%
- ±0.1%
- ±0.1%
- ±0.1%
- ±0.1%
- ±0.1%
- ±0.2%
- ±0.2%
- ±0.2%
- Syringe size accepted:
- 10 µl - 140 ml
- 10 µl - 140 ml
- 10 µl - 140 ml
- 10 µl - 140 ml
- 10 µl - 140 ml
- 10 µl - 140 ml
- 10 µl - 140 ml
- 10 µl - 140 ml
- 10 µl - 140 ml
- Syringe travel rate:
- <126.7"
- <126.7"
- <126.7"
- Warranty:
- 1 year
- 1 year
- 1 year
- 1 year
- 1 year
- 1 year
- 1 year
- 1 year
Specifications
Product Family Options
Product Information
- HeightLengthWidthPowerMax. Flow Rate Per SyringeNo. of SyringesAvailabilityPrice
- DUP-DO-NOT-USE 490Infusion Pump, Dual-Syringe, Programmable; 115 VACInfusion Pump, Dual-Syringe, Programmable; 115 VAC15.2 cm (6")27.94 cm (11")228.6 mm (9")115 VAC2Discontinued-Specifications:
More
Specifications
Cat. No.DUP-DO-NOT-USE 490Model74900-60Accuracy±1.0%InputLinear force40 lbs.Reproducibility±0.1%Syringe size accepted10 µl - 140 mlSyringe travel rateWarranty1 year - DUP-DO-NOT-USE 491Infusion Pump, Dual-Syringe, Programmable; 230 VACInfusion Pump, Dual-Syringe, Programmable; 230 VAC15.2 cm (6")27.94 cm (11")228.6 mm (9")230 VAC2Discontinued-Specifications:CE Compliant
More
Specifications
Cat. No.DUP-DO-NOT-USE 491Model74900-65Accuracy±1.0%InputLinear force40 lbs.Reproducibility±0.1%Syringe size accepted10 µl - 140 mlSyringe travel rateWarranty1 yearCE Compliant - MFLX74900-65Infusion Pump, Dual-Syringe, Programmable; 230 VACInfusion Pump, Dual-Syringe, Programmable; 230 VAC15.2 cm (6")27.94 cm (11")228.6 mm (9")230 VAC2Log in for availabilityEach (1UN)$111,150.00Specifications:CE CompliantIrregular Voltage
More
Specifications
Cat. No.MFLX74900-65Model74900-65Accuracy±1.0%InputLinear force40 lbs.Reproducibility±0.1%Syringe size accepted10 µl - 140 mlSyringe travel rateWarranty1 yearCE CompliantIrregular Voltage - DUP-DO-NOT-USE 080Infusion Pump, Ten-Syringe Capacity; 115 VAC 50/60 HzInfusion Pump, Ten-Syringe Capacity; 115 VAC 50/60 Hz15.2 cm (6")27.94 cm (11")304.8 mm (12")115 VAC10Discontinued-Specifications:
More
Specifications
Cat. No.DUP-DO-NOT-USE 080Model74900-80Accuracy±1.0%InputLinear force40 lbs.Reproducibility±0.1%Syringe size accepted10 µl - 140 mlSyringe travel rateWarranty1 year - DUP-DO-NOT-USE 085Infusion Pump, Ten-Syringe Capacity; 230 VAC 50/60 HzInfusion Pump, Ten-Syringe Capacity; 230 VAC 50/60 Hz15.2 cm (6")27.94 cm (11")304.8 mm (12")230 VAC10Discontinued-Specifications:CE Compliant
More
Specifications
Cat. No.DUP-DO-NOT-USE 085Model74900-85Accuracy±1.0%InputLinear force40 lbs.Reproducibility±0.1%Syringe size accepted10 µl - 140 mlSyringe travel rateWarranty1 yearCE Compliant - MFLX74900-85Infusion Pump, Ten-Syringe Capacity; 230 VAC 50/60 HzInfusion Pump, Ten-Syringe Capacity; 230 VAC 50/60 Hz15.2 cm (6")27.94 cm (11")304.8 mm (12")230 VAC10Discontinued-Specifications:CE CompliantIrregular Voltage
More
Specifications
Cat. No.MFLX74900-85Model74900-85Accuracy±1.0%InputLinear force40 lbs.Reproducibility±0.1%Syringe size accepted10 µl - 140 mlSyringe travel rateWarranty1 yearCE CompliantIrregular Voltage - DUP-DO-NOT-USE 010Infusion/Withdrawal Pump, Dual-Syringe, Programmable; 115 VACInfusion/Withdrawal Pump, Dual-Syringe, Programmable; 115 VAC23.5 cm (9.25")27.94 cm (11")127 mm (5")115 VAC147 ml/min2Discontinued-Specifications:
More
Specifications
Cat. No.DUP-DO-NOT-USE 010Model74901-00Accuracy±0.5%InputBaud rate: four settings up to 9600Linear force40 lbs.Reproducibility±0.2%Syringe size accepted10 µl - 140 mlSyringe travel rate<126.7"Warranty1 year - MFLX74901-05Infusion/Withdrawal pump, Dual-Syringe, Programmable; 230 VACInfusion/Withdrawal pump, Dual-Syringe, Programmable; 230 VAC23.5 cm (9.25")27.94 cm (11")127 mm (5")230 VAC147 ml/min2Discontinued-Specifications:CE CompliantIrregular Voltage
More
Specifications
Cat. No.MFLX74901-05Model74901-05Accuracy±0.5%InputBaud rate: four settings up to 9600Linear force40 lbs.Reproducibility±0.2%Syringe size accepted10 µl - 140 mlSyringe travel rate<126.7"WarrantyCE CompliantIrregular Voltage - MFLX74901-15Infusion/Withdrawal Pump, Ten-Syringe, Programmable; 230 VACInfusion/Withdrawal Pump, Ten-Syringe, Programmable; 230 VAC30.48 cm (12")27.94 cm (11")127 mm (5")230 VAC147 ml/min10Discontinued-Specifications:CE Compliant
More
Specifications
Cat. No.MFLX74901-15Model74901-15Accuracy±0.5%InputBaud rate: four settings up to 9600Linear force40 lbs.Reproducibility±0.2%Syringe size accepted10 µl - 140 mlSyringe travel rate<126.7"Warranty1 yearCE Compliant
Accessories
Product Information
- Catalog #AvailabilityPrice
- Pumps, Syringe Pumps Daisy Chain Cable for 74901-80 Dual Drive Syringe PumpPumps, Syringe Pumps Daisy Chain Cable for 74901-80 Dual Drive Syringe PumpMFLX74901-87Log in for availabilityEach (1UN) - $1,800.00
Product Information
- Catalog #AvailabilityPrice
- Pumps, Syringe Pumps RS-232 Connector Cable for 74901-80 Dual Drive Syringe PumpPumps, Syringe Pumps RS-232 Connector Cable for 74901-80 Dual Drive Syringe PumpMFLX74901-88Log in for availabilityEach (1UN) - $4,470.00
Recommendations will be personalized based on your shopping preferences only if you have given your consent by enabling "Enhance my Shopping Experience" on the "Personal Info page".
Otherwise, you will receive generic recommendations.